Preview only show first 10 pages with watermark. For full document please download

Lpx Series-high Rate / Ups

   EMBED


Share

Transcript

LPX SERIES-High Rate / UPS LPX2-400 (2V400AH) Specification Nominal Voltage 2V Nominal Capacity(8HR) 400.0AH Dimension 210 2mm (8.27 inches) Length 175 2mm (6.89 inches) Width 330 2mm (12.99 inches) Container Height Total Height (with Terminal) 350 2mm (13.78 inches) Approx 26.2 kg (57.8lbs) Approx Weight Terminal T11 Container Material ABS Rated Capacity 417.0 AH/41.7A 400.0 AH/50.0A 356.5 AH/71.3A 312.6 AH/104.2A 256.2 AH/250.0A (10hr ,1.80V/cell,250C/770F) (8hr,1.75V/cell,250C/770F) (5hr,1.75V/cell,250C/770F) (3hr,1.75V/cell,250C/770F) (1hr,1.60V/cell,250C/770F) Application Applications UPS (High rate) Max. Discharge Current 3200A (5s) High power backup supply Internal Resistance Approx 0.7mÙ Emergency power supply Starting system Operating Temp.Range Discharge : -15 500C (5 1220F) Charge : 0 400C (32 1040F ) Storage : -15 400C (5 1040F) Nominal Operating Temp. Range 25 Power tools Emergency lighting 30C (77 50F ) Electric starting Initial Charging Current less than 120.0A.Voltage Cycle Use 0 0 0 2.4V~2.5V at 25 C(77 F)Temp. Coefficient -5mV/ C No limit on Initial Charging Current Voltage Standby Use 2.25V~2.3V at 250 C(770 F)Temp. Coefficient -3mV/0C 103% 40o C (104o F) o o 100% 25 C ( 77 F ) o o 86% 0 C ( 32 F ) Leoch LPX series batteries may be stored for up to 6 months at 250 C(770F) and then a freshening charge is required. For higher temperatures the time interval will be shorter. Capacity affected by Temperature Self Discharge VdS t est ed 9 0 0 Germany Constant Current Discharge (Amperes) at 25 C (77 F ) F.V/Time 5min 10min 15min 20min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 20h 1.85V/cell 486.0 428.3 376.5 333.3 278.5 226.3 184.6 123.8 94.6 76.3 65.2 57.5 46.7 39.5 20.9 1.80V/cell 591.7 501.3 429.0 373.5 306.0 243.3 196.7 130.2 102.5 79.0 67.9 59.8 48.8 41.7 21.7 1.75V/cell 691.5 574.4 485.4 414.0 332.9 263.3 211.7 138.1 104.2 83.3 71.3 62.7 50.0 42.2 21.9 1.70V/cell 791.5 649.4 536.5 455.2 361.7 281.3 224.2 145.8 108.8 86.7 74.2 65.0 51.7 43.2 22.5 1.65V/cell 849.6 694.2 570.8 481.3 379.0 292.5 232.9 150.6 112.3 89.4 76.3 66.0 52.7 43.9 22.8 1.60V/cell \ 786.0 641.7 536.5 414.6 316.3 250.0 158.1 116.9 93.1 79.8 69.0 54.6 45.3 23.6 Constant Power Discharge (Watts) at 25 0C (77 0F ) F.V/Time 5min 10min 15min 20min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 20h 1.85V/cell 893.8 795.4 706.3 631.7 533.8 437.1 358.1 241.5 185.4 149.8 128.5 113.5 92.5 78.6 41.8 1.80V/cell 1076.3 920.0 794.2 697.5 577.5 466.5 379.4 252.5 199.8 154.2 133.1 117.7 96.5 82.6 43.2 1.75V/cell 1231.3 1037.5 887.5 765.6 622.9 500.2 406.5 266.9 202.1 162.1 139.2 123.1 98.8 83.8 43.6 1.70V/cell 1370.2 1146.3 967.3 835.6 673.1 532.3 428.8 281.0 210.6 168.5 144.6 127.3 101.9 85.6 44.7 1.65V/cell 1450.2 1214.4 1021.3 876.7 699.6 548.3 442.5 288.8 216.5 172.9 148.1 129.2 103.5 86.9 45.3 1.60V/cell 1344.2 1129.2 966.9 760.0 590.0 472.5 301.7 224.6 179.6 154.6 134.4 107.1 89.6 46.5 \ 1 Dimensions T11 Terminal Unit: mm [inches] 20 [0.787] 350 2 337 2 330 2 120 2 175 2 7 [0.276] M8 [0.315] 160 2 210 2 Discharge Characteristics Float Charging Characteristics 2V Battery V 2.18 Charge Volume 0 Temperature:25C Charging Current (A) % Charging Voltage 0 0.1CA-2.25V/cell temperature25C (V/cell) Terminal Voltage(V) 2.00 120 0.10C 2.4 100 0.08C 2.3 80 0.06C 2.2 60 0.04C 2.1 40 0.02C 2.0 20 0C Charged Volume 1.83 0.6C 0.4C 1.67 0.106C 0.056C 0.21C Charge Voltage (Constant 2.25V/cell) 1C After 50% Discharge 2C 1.5 1.33 3C After 100% Discharge Charging Current 1 2 4 6 810 S 20 40 60 2 4 6 8 10 min 20 40 60 2 4 6 8 10 H 20 0 Discharge Time Capacity (%) 8 12 16 20 24 28 32 36 Charging Time(Hours) Effect of Temperature on Long Term Float Life Temperature Effects in Relation to Battery Capacity 120 12 100 10 8 5C 0.1 2 C 0.2 1 80 4 Charging voltage : 2.25V/cell 5 3 60 1.0C 40 2 2. 0 C 20 0 -20 0 -10 0 10 30 20 40 20 68 50 Temperature( 0C ) 40 104 50 0C 122 OF Battery temperature 100 100C Remaining Capacity(%) 30 86 Self Discharge Characteristics A 80 250C 60 B 300C A No supplementary charge required (Carry out supplementary charge before use if 100% capacity is required.) B Supplementary charge required before use.Optional charging way as below: 1.Charged for above 3 days at limted current 0.25CA and constant volatge 2.25V/cell. 2.Charged for above 20hours at limted current 0.25CA and constant volatge 2.45V/cell. 3.Charged for 8~10hours at limted current 0.05CA . C Supplementary charge may often fail to recover the capacity. The battery should never be left standing till this is reached. 0 40 C 40 C 20 0 0 2 4 6 8 10 Storage Time(Months) 12 Add: 12C Wheatstone Park, Waterwells Business Park, Gloucester, GL2 2AQ. UK. Tel: +44(0) 1452 751016 Fax: +44 (0)1452-690125 E-mail: [email protected] 2