Preview only show first 10 pages with watermark. For full document please download

Lpx Series-high Rate / Ups

   EMBED


Share

Transcript

LPX SERIES-High Rate / UPS LPX12-35 (12V35AH) Specification Nominal Voltage 12V Watts(15min Rate) 137.5 Watte at 1.67V/cell Dimension Length Width Container Height Total Height (with Terminal) 195 130 164 180 1mm (7.68 inches) 1mm (5.12 inches) 1mm (6.46 inches) 1mm (7.09 inches) Main tena nce- V35AH) LPX12-35(12 ry Lead -acid Batte free Seal ed GE CONS TANT Stand by Approx 10.5 kg (23.15lbs) Approx Weight Terminal T10 Container Material ABS Rated Capacity 35.2 AH/1.76A 34.2 AH/3.42A 30.7 AH/6.14A 27.9 AH/9.3A 24.0 AH/24.0A CHAR VOLTAGE 13.5- 13.8 use: use: Cycle nt: Initia l curre V V 10.5 A 14.4- 15.0 Less t han emble, Do not disass Warnin g: ion, or burns. explos ate. O or inciner Risk of fire, the 50C , heat above Pb. MH268 66 Non-spi llable ED RY CO.,LTD. BATTERY MUST BE RECYCL LEOCH BATTE IN CHINA Pb MADE (20hr,1.80V/cell,250C/770F) (10hr,1.80V/cell,250C/770F) (5hr,1.75V/cell,250C/770F) (3hr,1.75V/cell,250C/770F) (1hr,1.60V/cell,250C/770F) Application Applications UPS (High rate) High power backup supply Max. Discharge Current 525A (5s) Internal Resistance Approx 12mÙ Operating Temp.Range Discharge : -15 500C (5 1220F) Charge : 0 400C (32 1040F ) Storage : -15 400C (5 1040F) Nominal Operating Temp. Range 25 Emergency power supply Starting system Power tools Emergency lighting 30C (77 50F ) Electric starting Initial Charging Current less than10.5A.Voltage Cycle Use 14.4V~15.0V at 250 C(770 F)Temp. Coefficient -30mV/0C No limit on Initial Charging Current Voltage Standby Use 13.5V~13.8V at 250 C(770 F)Temp. Coefficient -20mV/0C 103% 40o C (104o F) o o 100% 25 C ( 77 F ) o o 86% 0 C ( 32 F ) Leoch LPX series batteries may be stored for up to 6 months at 250 C(770F) and then a freshening charge is required. For higher temperatures the time interval will be shorter. Capacity affected by Temperature Self Discharge VdS t est ed 9 0 0 Germany Constant Current Discharge (Amperes) at 25 C (77 F ) F.V/Time 5min 10min 15min 20min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 20h 1.85V/cell 96.3 70.9 59.7 49.8 37.2 26.7 20.9 12.1 8.76 6.93 5.92 5.02 4.07 3.35 1.72 1.80V/cell 112.4 78.1 64.6 53.3 38.9 27.8 22.0 12.6 9.1 7.17 5.98 5.18 4.16 3.42 1.76 1.75V/cell 126.8 85.6 69.3 56.2 40.9 29.0 22.7 13.0 9.3 7.39 6.14 5.32 4.22 3.46 1.78 1.70V/cell 139.6 92.3 73.7 59.3 42.6 30.0 23.4 13.2 9.5 7.55 6.27 5.43 4.27 3.50 1.80 1.65V/cell 154.0 98.0 77.3 62.0 44.1 30.9 24.0 13.6 9.7 7.71 6.39 5.51 4.35 3.56 1.81 1.60V/cell 169.8 105.4 81.1 64.7 45.6 31.8 24.7 13.9 9.9 7.81 6.49 5.58 4.41 3.61 1.83 Constant Power Discharge (Watts) at 25 0C (77 0F ) F.V/Time 5min 10min 15min 20min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 20h 1.85V/cell 176.2 131.0 111.4 93.9 70.8 51.2 40.3 23.5 17.1 13.7 11.8 10.0 8.22 6.83 3.53 1.80V/cell 202.1 142.1 118.9 99.0 73.0 52.8 42.2 24.3 17.6 14.1 11.8 10.3 8.38 6.96 3.60 1.75V/cell 224.5 153.8 126.0 103.4 76.1 54.8 43.4 25.0 18.0 14.5 12.1 10.6 8.48 7.03 3.64 1.70V/cell 241.4 163.1 132.4 108.3 78.9 56.5 44.5 25.3 18.3 14.8 12.4 10.8 8.57 7.11 3.68 1.65V/cell 261.3 170.5 137.5 112.3 81.0 57.6 45.4 25.9 18.7 15.0 12.5 10.9 8.70 7.22 3.69 1.60V/cell 281.5 179.2 141.9 116.0 83.1 59.0 46.4 26.4 19.0 15.2 12.7 11.0 8.80 7.31 3.73 1 Dimensions T10 Terminal CONSTANT VOLTAGE CHARGE Standby use: Cycle use: 13.5-13.8 V 14.4-15.0 Initial current: Less t han V 10.5 A 130 2 49 2 LPX12-35 (12V35AH) Maintenance-free Sealed Lead-acid Battery 180 2 164 2 Unit: mm [inches] Warning: Risk of fire, explosion, or burns. Do not disassemble, heat above the 50 O C, or incinerate. MH26866 Pb. LEOCH BATTERY CO.,LTD. Non-spillable MADE IN CHINA BATTERY MUST BE RECYCLED Pb Discharge Characteristics Float Charging Characteristics 6V Battery12V Battery V V 13.0 6.5 Charge Volume 0 Temperature:25C Terminal Voltage(V) 6.0 12.0 5.5 11.0 0.6C 0.4C 5.0 0.95C 0.21C 0.05C Charging Current (A) % Charging Voltage 120 0.10C 2.4 100 0.08C 2.3 80 0.06C 2.2 60 0.04C 2.1 40 0.02C 2.0 20 0C Charged Volume Charge Voltage (Constant 2.25V/cell) 1C 10.0 After 50% Discharge 2C 4.5 9.0 4.0 8.0 3C 7C 1 2 4 6 810 S 40 60 20 After 100% Discharge 5C 2 4 Charging Current 6 8 10 min 20 40 60 2 4 6 8 10 H 20 0 Discharge Time 8 12 16 20 24 28 32 36 Effect of Temperature on Long Term Float Life 120 12 100 10 8 5C 0.1 2 C 0.2 8 80 4 Charging Time(Hours) Temperature Effects in Relation to Battery Capacity Capacity (%) 0 0.1CA-2.25V/cell temperature25C (V/cell) Charging voltage : 2.25V/cell 5 3 60 1.0C 40 2 2. 0 C 20 0 -20 0 -10 0 10 30 20 40 20 68 50 Temperature( 0C ) 40 104 50 0C 122 OF Battery temperature 100 100C Remaining Capacity(%) 30 86 Self Discharge Characteristics A 80 250C 60 B 300C A No supplementary charge required (Carry out supplementary charge before use if 100% capacity is required.) B Supplementary charge required before use.Optional charging way as below: 1.Charged for above 3 days at limted current 0.25CA and constant volatge 2.25V/cell. 2.Charged for above 20hours at limted current 0.25CA and constant volatge 2.45V/cell. 3.Charged for 8~10hours at limted current 0.05CA . C Supplementary charge may often fail to recover the capacity. The battery should never be left standing till this is reached. 0 40 C 40 C 20 0 0 2 6 4 8 10 Storage Time(Months) 12 Sales Office China sales office: North America sales office: Europe sales office: Add:5th Floor,Xinbaohui Bldg.,Nanhai Blvd., Nanshan,Shenzhen, China. 518052 Tel:+ 86-755-86036060 (100 lines) Fax: +86-755-26067269 E-mail:[email protected] Add: 19751 Descartes, Unit A, Foothill Ranch, CA 92610, USA Tel: 949-588-5853 Fax: 949-588-5966 E-mail: [email protected] Add: 9B Wheatstone Park, Waterwells Business Park, Gloucester, GL2 2AQ. UK. Tel: +44(0) 1452 729428 Fax: +44 (0)1452-690125 E-mail: [email protected] 2