LPX SERIES-High Rate / UPS LPX12-24 (12V24AH) Specification Nominal Voltage 12V Watts(15min Rate) 99.8 Watts at 1.67V/cell Dimension Length Width Container Height Total Height (with Terminal) 166.5 175 125 125 1mm (6.56 inches) 1mm (6.89 inches) 1mm (4.92 inches) 1mm (4.92 inches) Mai nten anc NT VOLTAG use: Stan dby use: Cyc le ent: Initia l curr Approx 8.8 kg (19.4lbs) Approx Weight Terminal V24AH) LPX12-24(12 id Bat tery led Lea d-ac e-fr ee Sea E CHA RGE CON STA semb not disas burns . Do sion, or Warn ing: exploO rate. , or incine Risk of fire, the 50C heat above T3 / T12 V V 13.5 -13. 8 14.4 -15. 0 L ess t han 7.2 A le, Pb. MH26 866 TD. ERY CO.,L LEOC H BATT IN CHINA Non-sp illable BATTE RY MUST BE RECYC LED MADE Container Material ABS Rated Capacity 25.5 AH/2.55A 24.0 AH/3.00A 21.8 AH/4.37A 20.1 AH/6.69A 19.7 AH/19.7A (10hr ,1.80V/cell,250C/770F) (8hr,1.80V/cell,250C/770F) (5hr,1.75V/cell,250C/770F) (3hr,1.75V/cell,250C/770F) (1hr,1.60V/cell,250C/770F) Application Applications UPS (High rate) High power backup supply Max. Discharge Current 360A (5s) Internal Resistance Approx 12mÙ Operating Temp.Range Discharge : -15 500C (5 1220F) Charge : 0 400C (32 1040F ) Storage : -15 400C (5 1040F) Nominal Operating Temp. Range 25 Emergency power supply Starting system Power tools Emergency lighting 30C (77 50F ) Electric starting Initial Charging Current less than 7.2A.Voltage Cycle Use 14.4V~15.0V at 250 C(770 F)Temp. Coefficient -30mV/0C No limit on Initial Charging Current Voltage Standby Use 13.5V~13.8V at 250 C(770 F)Temp. Coefficient -20mV/0C 103% 40o C (104o F) o o 100% 25 C ( 77 F ) o o 86% 0 C ( 32 F ) Leoch LPX series batteries may be stored for up to 6 months at 250 C(770F) and then a freshening charge is required. For higher temperatures the time interval will be shorter. Capacity affected by Temperature Self Discharge VdS t est ed 9 0 0 Germany Constant Current Discharge (Amperes) at 25 C (77 F ) F.V/Time 5min 10min 15min 20min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 20h 1.85V/cell 68.0 51.4 41.2 34.6 26.8 19.9 15.9 8.64 6.05 4.77 4.05 3.46 2.87 2.45 1.41 1.80V/cell 79.3 58.1 45.2 37.2 28.7 21.6 17.0 9.25 6.51 5.09 4.20 3.67 3.00 2.55 1.43 1.75V/cell 89.4 63.8 49.4 40.0 29.9 22.4 17.8 9.59 6.69 5.21 4.37 3.76 3.08 2.58 1.45 1.70V/cell 98.5 69.5 52.8 42.0 31.0 23.4 18.3 10.0 6.88 5.34 4.47 3.84 3.14 2.62 1.47 1.67V/cell 108.6 75.1 56.1 44.6 32.8 24.0 19.0 10.3 7.10 5.53 4.56 3.93 3.19 2.68 1.49 1.60V/cell 119.8 81.5 59.9 47.5 34.6 24.9 19.7 10.6 7.32 5.70 4.69 4.02 3.22 2.70 1.50 Constant Power Discharge (Watts) at 25 0C (77 0F ) F.V/Time 5min 10min 15min 20min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 20h 1.85V/cell 124.3 94.9 76.8 65.2 51.0 38.2 30.7 16.8 11.8 9.43 8.07 6.93 5.64 4.85 2.80 1.80V/cell 143.5 106.0 83.2 69.1 53.9 41.2 32.7 17.8 12.6 9.99 8.31 7.30 5.87 5.02 2.84 1.75V/cell 158.3 114.7 89.8 73.5 55.6 42.4 34.0 18.4 12.9 10.2 8.63 7.48 6.00 5.09 2.88 1.70V/cell 169.6 122.1 94.6 76.7 57.5 43.9 35.0 19.1 13.3 10.5 8.81 7.62 6.11 5.16 2.92 1.67V/cell 184.3 130.6 99.8 80.9 60.1 44.6 35.9 19.6 13.7 10.8 8.96 7.77 6.20 5.27 2.96 1.60V/cell 198.6 138.5 105.0 85.3 63.1 46.3 37.0 20.1 14.0 11.1 9.18 7.91 6.25 5.32 2.97 1 Dimensions T3 Terminal 14 [0.551] 1 Unit: mm [inches] use: use: Initial current: 13.5-13.8 V 14.4-15.0 V Less t han 7.2 A MH26866 Pb. LEOCH BATTERY CO.,LTD. Non-spillable MADE IN CHINA BATTERY MUST BE RECYCLED 16 13 [0.512] 6 [0.236] CONSTANT VOLTAGE CHARGE Standby Cycle Warning: Risk of fire, explosion, or burns. Do not disassemble, heat above the 50 O C, or incinerate. 175 4.5 [0.177] LPX12-24 (12V24AH) Maintenance-free Sealed Lead-acid Battery 112 125 1 2 [0.079] 140 166.5 1 Discharge Characteristics Float Charging Characteristics 6V Battery12V Battery V V 13.0 6.5 Charge Volume 0 Temperature:25C Terminal Voltage(V) 6.0 12.0 5.5 11.0 0.74C0.4C 5.0 0.106C 0.059C 0.22C Charging Current (A) % Charging Voltage 120 0.10C 2.4 100 0.08C 2.3 80 0.06C 2.2 60 0.04C 2.1 40 0.02C 2.0 20 0C Charged Volume Charge Voltage (Constant 2.25V/cell) 1.3C 10.0 After 50% Discharge 2.5C 4.5 9.0 4.0 8.0 4C 7C 10C 1 2 4 6 810 S 40 60 20 After 100% Discharge 5C 2 4 Charging Current 6 8 10 min 20 40 60 2 4 6 8 10 H 20 0 Discharge Time 8 12 16 20 24 28 32 36 Effect of Temperature on Long Term Float Life 120 12 100 10 8 5C 0.1 2 C 0.2 8 80 4 Charging Time(Hours) Temperature Effects in Relation to Battery Capacity Capacity (%) 0 0.1CA-2.25V/cell temperature25C (V/cell) Charging voltage : 2.25V/cell 5 3 60 1.0C 40 2 2. 0 C 20 0 -20 0 -10 0 10 30 20 40 20 68 50 Temperature( 0C ) 40 104 50 0C 122 OF Battery temperature 100 100C Remaining Capacity(%) 30 86 Self Discharge Characteristics A 80 250C 60 B 300C A No supplementary charge required (Carry out supplementary charge before use if 100% capacity is required.) B Supplementary charge required before use.Optional charging way as below: 1.Charged for above 3 days at limted current 0.25CA and constant volatge 2.25V/cell. 2.Charged for above 20hours at limted current 0.25CA and constant volatge 2.45V/cell. 3.Charged for 8~10hours at limted current 0.05CA . C Supplementary charge may often fail to recover the capacity. The battery should never be left standing till this is reached. 0 40 C 40 C 20 0 0 2 6 4 8 10 Storage Time(Months) 12 Sales Office China sales office: North America sales office: Europe sales office: Add:5th Floor,Xinbaohui Bldg.,Nanhai Blvd., Nanshan,Shenzhen, China. 518052 Tel:+ 86-755-86036060 (100 lines) Fax: +86-755-26067269 E-mail:[email protected] Http://www.leoch.com Add: 19751 Descartes, Unit A, Foothill Ranch, CA 92610, USA Tel: 949-588-5853 Fax: 949-588-5966 E-mail: [email protected] Http://www.leoch.us Add: 9B Wheatstone Park, Waterwells Business Park, Gloucester, GL2 2AQ. UK. Tel: +44(0) 1452 729428 Fax: +44 (0)1452-690125 E-mail: [email protected] 2