Transcript
Technical Data Sheet
LS-100—Internet Protocol Interface Device By Draper
USES:
The LS-100 is used to control one 115 volt motor by network communication. It is used in conjunction with the LVC-IV.
COMPATIBILITY: 1. Other controls may be connected to the LVC-IV simultaneously: a. LVC-S low voltage wall switch (or Auxiliary control systems employing “dry” contacts). b. WRT/R radio frequency remote control package (splitter and power supply required). 2. WRT/R radio frequency remote control receiver can also be connected to the IPD4.
CONTACTS:
None. The contacts are part of the LVC-IV.
RATING:
FCC(A), CE(A), MIC.
DESCRIPTION:
Ethernet to Serial bridge device to control R2D7 via Ethernet. Comes with its own power supply and instructions. The LS100 can have a static IP address assigned to it, allowing for direct access to any device connected to it via Ethernet connection. One male DB9 serial port for data communication/serial console. Serial speeds 1200bps to 115200bps. Signals: Rx, Tx, RTS, CTS, DTR, DSR, GND. Network Interfaces: 10 Base-T Ethernet with RJ45 Ethernet connector. Supports static and dynamic IP address. Protocols: ARP, IP/ICMP, TCP, Telnet, DHCP client, PPPoE.
PART NUMBER:
C103.062 121243 - (LVC-IV & LS100 Kit)
ILLUSTRATION:
27/8” 4” 1”
Copyright ©2015 Draper Inc. Form LS-100_TechDataSheet15
Printer in U.S.A.