Preview only show first 10 pages with watermark. For full document please download

Ls-5000series Ls-5000series

   EMBED


Share

Transcript

MAIN MENU PRODUCTS High-speed Laser Scan Micrometers LS-5000 Series Features ● Resolution of 0.05 µm 0.002 Mil ● High-speed scanning rate of 1200 scans/sec ● Touch-screen monitor ● Up to four heads connected to one controller Measuring range Standard - 0.2 to 40 mm (0.01" to 1.57") dia. APPLICATIONS INDEX SELECTION GUIDE Description High-speed sampling at 1200 scans/sec A newly developed 12-surface polygon mirror and a high-precision motor enables a high-speed sampling rate of 1200 scans/sec - a rate 3 times faster than our previous models. The LS-5000 Series has the extra performance needed to continuously measure extruded and moving objects - down to the sub-micron. Large touch screen for easy operation The system is operated via a touch screen, in which menu items are selected simply by touching the screen. Even those unfamiliar with computers can operate the system easily. Enclosure rating conforms to IP-64 (NEMA 4) requirements (IP-65 with LS-5121) Wide-range - 0.8 to 120 mm (0.03" to 4.72") dia. Connects up to four scanning heads Up to four scanning heads can be connected to a single controller for centralized control. This provides a low-cost system for measuring multiple lines simultaneously. Wide measuring range Objects from 0.2 mm to 120 mm 0.02" to 4.72" in diameter can be measured. The LS-5121 increases transmitter/receiver distance to maximum of 1000 mm 39.37". A full range of products that solve the toughest applications Built-in display for easy installation and setup (LS-5501) This compact controller can be installed almost anywhere its built-in display allows the system to be setup and installed easily for immediate use. Low-cost system for control via personal computer (LS-5001) This low-cost model without a display can be controlled and monitored externally using a computer. Special software is provided. Refer to P.551 for a list of products complying with EMC directive. 418 Separate external display can be installed within a control panel for ease of operation (LS-5001/D501) In this model the display and controller are separate to allow the system to be incorporated within a control panel or other on-site equipment as required. MAIN MENU PRODUCTS APPLICATIONS INDEX SELECTION GUIDE High-speed Laser Scan Micrometers LS-5000 Applications Measuring the outer diameter of the transparent tubes in the X and Y directions. Measuring the sheet width and controlling the sheet edges. Measuring the outer diameter, eccentricity and gap. Measuring the outer diameter of a large roller shaft. Specifications Scanning head Type Standard LS-5041 LS-5121 LS-5501/LS-5001 LS-5501/LS-5001 0.2 to 40 mm 0.01" to 1.57" 0.8 to 120 mm 0.03" to 4.72" 0.2 mm 0.01" 0.8 mm 0.03" Transmitter/receiver distance 160 ±40 mm 6.30" ±1.57" 400 ±100 mm 15.75" ±3.94", 1000 mm 39.37" max.1. Light source Red semiconductor laser Red semiconductor laser 670 nm 670 nm Class II Class II Model Scanning head Wide range Controller Measuring range Minimum target width Wavelength Class Measurement accuracy Repeatability Display resolution Laser scan rate Laser scan velocity FDA IEC Class 2 Class 2 ±2 µm max.2. 0.08 Mil ±8 µm max.3. 0.32 Mil ±0.3 µm max.4. 0.01 Mil ±1 µm max.5. 0.04 Mil 0.05 µm 0.002 Mil 0.05 µm 0.002 Mil 1200 scans/sec 1200 scans/sec 121 m 397.0'/sec 504 m 1653.5' /sec Laser scan range Approx. 46 mm 1.81" Approx. 124 mm 4.88" Enclosure rating IP-64 (NEMA 4) IP-65 (NEMA 4) 0 to +50°C 0 to +50°C Approx. 1.4 kg (including base) Approx. 5.5 kg (including base) Ambient temperature Weight 1. The measurable area is within 800 mm 31.5" from the transmitter. 2. When a round rod 10 mm 0.39" in diameter is measured in a 10 mm x 20 mm 0.39" x 0.79" measuring area. 3. When a rod 40 mm 1.57" in dia. is measured in a 40 mm x 80 mm 1.57" x 3.15" measuring area. 4. When the average number of measurements is set to 768 in a 10 mm x 20 mm 0.39" x 0.79" measuring area. 5. When the average number of measurements is set to 768 in a 40 mm x 80 mm 1.57" x 3.15" measuring area. 419 MAIN MENU PRODUCTS APPLICATIONS INDEX SELECTION GUIDE LS-5000 High-speed Laser Scan Micrometers Controller Display unit Type Built-in display Separate display — Model LS-5501 LS-5001 LS-D5012. 4 max 4 max — LCD display Number of connectable scanning heads Measurement display Display — LCD display Display range -99.99995 to 999.99995 mm -0.99999" to 9.99999" — -99.99995 to 999.99995 mm -0.99999" to 9.99999" Display units mm/inches selectable — mm/inches selectable Tolerance check output display 7-level LCD indicator — 7-level LCD indicator — LCD (Green LED at scanning head) Non-voltage input (contact/solid state) — Laser emission indicator LCD (Green LED at scanning head) Terminal block input Laser stop input Interface RS-232C Program selection input Non-voltage input (contact/solid state) Measurement data output and control output — Timing input, Reset input, Auto-zero input Non-voltage input (contact/solid state) I/O board1. Analog voltage output 7-level comparator output Power supply voltage — ± 10 V Output impedance: 100 Ω ± 10 V Output impedance: 100 Ω — 100 mA max. (40 V max.) 100 mA max. (40 V max.) — 85 to 264 VAC, 50/60 Hz 24 VDC ±10% 24 VDC ±10% Power consumption 85 VA max. 1.4 A max. 0.6 A max. Ambient temperature 0 to +45°C 0 to +45°C 0 to +45°C Approx. 3.7 kg Approx. 1.1 kg Approx. 0.7 kg Weight 1.The I/O board is handled as options. 2.The LS-D501 does not comply with EMC directive. Note: BCD output is available as an option. Please inquire with KEYENCE. Functions Easy addition and replacement of scanning heads with interface board system A board system is used for connecting the scanning heads. The boards are equipped with correction ROM to ensure compatibility. This feature eliminates the conventional problem of matching pairs when adding or replacing a scanning head. Pitch measurement mode for displaying maximum and minimum values The LS-5000 Series has a pitch measurement mode. In this mode, the system measures the center pitch or alignment of connector pins and similar objects up to a maximum of 100 points. The maximum and minimum values measured can then be displayed, together with the results of the tolerance check. Multiple simultaneous calculation modes A wide range of calculation modes and functions are provided to fully utilize the 4-head/4-channel output. Addition, subtraction, and division of measured data are all possible. These can be used for various tasks - from measuring the outer diameter of thick objects to measuring the thickness of films. LASER ON OUT1 P. 1 AREA2 AREA3 AREA4 +A1 +A2 +A3 OFF AVERAGE 1 (0.833ms) MEASURING MODE NORMAL DIGIT SUPPRESS NONE HELP SELF-TIMING INTERVAL (ms) 500 NEXT ESC Analog I/O interface boards can be added. The board system allows I/O boards to be freely combined as required. Upgrading a single controller system can be done easily. 2-channel analog I/O board LS-B11 Equipped with a 2-channel selector output (NPN open collector) and analog voltage output. The board can also handle timing input and auto-zero input. Miscellaneous functions • Self-timing function suitable for on-line operation. • On-line measurement modes • 7-level comparator function • 16-program memory with one-touch selection 420 NOR MAL OUTPUT MODE AREA1 CALCULATE MAIN MENU PRODUCTS APPLICATIONS INDEX SELECTION GUIDE High-speed Laser Scan Micrometers LS-5000 Part Names and Functions LS-5501 (Built-in display type) Front LS-5001 (Separate display type) Rear 1 2 Rear 3 2 1 11 12 4 5 13 6 7 3 4 8 9 5 24 VDC 0 V N/C 6 7 10 1 2 3 4 5 6 7 8 9 10 11 12 13 8 1 2 3 4 5 6 7 8 Measured value display and function setup/operating unit I/O connector (LS-B11) Analog output BNC connector (LS-B11) Scanning head connecting port DIP switch Laser emission control input terminal Program selection input terminal Power supply switch Power supply input Fuse holder (250 V, 3.15 A) Expansion slot 1 for I/O board Expansion slot 2 for I/O board RS-232C connecting port I/O connector (LS-B11) Analog output BNC connector (LS-B11) Scanning head connecting port DIP switch Laser emission control input terminal Program selection input terminal Power supply terminal (24 VDC) RS-232C connecting port Outline of Measurements Area/Segment/Edge EDGE 0 When a target is placed in the measuring area, there are areas where the laser beam is received (laser beam enters the receiver), and where the laser beam is interrupted by the target (shadow of the target is projected on the receiver). The border between the light and dark areas is called “EDGE”. Each section divided by the edge is called a “SEGMENT”. The “AREA” is determined by two edges and includes all “SEGMENTS” between these two edges. The position of the photodiode for synchronization is called “EDGE 0”. EDGE 0 can be used as a reference point during roller oscillation measurement or sheet edge control. (No reference edge is required.) Example: Roller oscillation measurement Photodiode for synchronization Photodiode for synchronization Edge 0 Edge 1 Edge 2 Laser scanning direction Transmitter Rotating Roller Receiver This width can be measured when SEG(m,n) is set to (0,2) in Normal mode. Edge 3 Edge 4 Edge 5 (n-1) Edge 6 (n) Transmitter Target Receiver Normal mode * The edge number is counted in the laser scanning direction starting at T.EDGE (top edge). The LS-5000 Series has two measuring modes; NORMAL and PITCH. NORMAL mode provides four modes: “DIA”, “T.EDGE (Top Edge)”, “B.EDGE (Bottom Edge)” and “SEG(m,n)”. The function of each mode is described on the next page. Select the mode that suits your measurement condition. 421 MAIN MENU PRODUCTS APPLICATIONS INDEX SELECTION GUIDE LS-5000 High-speed Laser Scan Micrometers DIA mode SEG (m,n) mode Measurement of outer diameter of rod or electric wire Example: Outer diameter measurement using a rod or transparent object Setting the measurement position to measure inner diameter using a bearing Example: Inner diameter measurement using a bearing The width between the lower edge of the first light segment and the top edge of the last light segment is measured. When two edges are specified, the width between these edges is measured. * (m,n) indicates any number between 0 and 254. “m” should be smaller than “n”. • When one target is measured Photodiode for synchronization Laser scanning direction Photodiode for synchronization Measured width Transmitter Target 0 1 2 3 4 Receiver Transmitter • When several targets are measured Measured width Target Receiver T.EDGE/B.EDGE modes Measurement of gap between rollers or position of target edge Example: Measurement of a gap between rollers T.EDGE: Measures the width of the first light segment. B.EDGE: Measures the width of the last light segment. Photodiode for synchronization Target Transmitter Receiver Both the T.EDGE and B.EDGE modes measure this width. Photodiode for synchronization Transmitter 422 Target The T.EDGE mode measures this width. The B.EDGE mode measures this width. Receiver Receiver [Note] Photodiode for synchronization Transmitter Target This width is measured when SEG(3,4) is set. 5 6 DIA mode Since DIA mode is basically intended for outer diameter measurement of a rod, transparent tube or other round surface, the measurement error due to the round surface is calibrated. * To perform outer diameter measurement of a round target, select DIA mode. MAIN MENU PRODUCTS APPLICATIONS INDEX SELECTION GUIDE High-speed Laser Scan Micrometers LS-5000 Input/Output Circuits Input circuit diagrams Output circuit diagrams I/O board (Synchronous [timing] input, Reset input, Autozero input) BCD board (EXE IN, EXE TRG) I/O board (7-level comparator output) BCD board (BCD output)(Strobe output) 12 V IN 1 KΩ IN NPN output or 470 Ω GND GND GND Program selection input (Terminal block) I/O board (Analog output) +5 V 47 Ω 47 Ω Output IN 1.5 KΩ IN or 0V GND 3 KΩ GND 0V RS-232C communication protocol ■ Connection with a personal computer Using the RS-232C interface, the LS-5000 Series can communicate with a personal computer. Data transmission and setting changes can be remotely controlled. Straight cable OP-26486/OP-26487 (D-sub 9-pin connector/ 2.5-m cable) 8.2' Personal computer Warning The LS-5000 Series conforms to the FDA and IEC standards as follows: Model FDA IEC LS-5041/LS-5121 IEC Class 2 FDA Class II CAUTION Class II LASER RADIATION-DO NOT STARE INTO BEAM Class 2 SEMICONDUCTOR LASER 670nm MAXIMUM OUTPUT 0.8mW PULSE DURATION 63µs CLASS II LASER PRODUCT AVOID EXPOSURE LASER RADIATION DO NOT STARE INTO BEAM LASER RADIATION IS EMITTED FROM THIS APERTURE. Maximum output Pulse duration Emitted wavelengt h 0.8mW 63µs 67 0 nm CLASS 2 LASER PRODUCT in conformity to IEC825-1 11. 1993 423 MAIN MENU PRODUCTS APPLICATIONS INDEX SELECTION GUIDE LS-5000 High-speed Laser Scan Micrometers Dimensions Scanning head LS-5041 0.51" 13 24 0.94" 1.34" 34 21 0.83" 0.59" 15 5 0.20" ø0.22" 3-ø 5.5 mounting hole 32 1.26" Measuring area 105 4.13" 105 4.13" 0.69" 17.5 1.57" 40 86 76 3.39"2.99" 49 1.93" 5 0.20" 17 0.67" 0.59" 15 55 55 2.17" 2.17" ø0.22" 3-ø 5.5 Mounting hole 17 0.67" 0.94" 24 Unit: mm ø0.18" 4-ø 4.5 through-hole ø 8 spot facing, 4.5 (d) ø0.31" 0.18" 4-M4 effective depth 100.39" 0.39" 10 3.03" 77 3.35" 85 76 86 2.99" 3.39" 3.15" 80 3.15" 80 0.39" 10 3.03" 77 3.35" 85 6.30" 160 7.09" 180 5 0.20" 18 0.20" 0.39" 4-M4, effective depth 10 5 0.20" 4-ø 4.5 through-hole ø0.18" 0.20" 5 16.5 17 0.65" 0.67" 0.94" 24 24 0.94" 135 5.31" (9) (0.35") 135 5.31" (9) (0.35") 360 14.17" 2-M4 17 0.67" 17 71 2.80" 2-M4 97 3.82" 97 3.82" 71 2.80" 17 0.67" 17 LS-5121 ø0.26" 4-ø 6.5 through-hole ø 14 spot facing, 7 (d) 0.28" ø0.55" 4-M4 effective depth 10 0.39" 55 2.17" 1.38" 35 10 0.39" 25 0.98" 150 5.91" 20* 0.79" 25 0.98" 150 5.91" *20 ±2 mm at the measuring center 0.79" ± 0.08" 3-ø 7.5 ø0.30" mounting hole 1.26" 1.77" 65 2.56" 45 29.5 1.16" 32 155 6.10" Measuring area 180 7.09"168 6.61" 6 20 0.24" 0.79" 3-ø 7.5 ø0.30" mounting hole 17 175 6.89" 0.67" 168 6.61"180 89 7.09" 120 4.72" 4.92" 125 200 7.87" 15 0.59" 200 7.87" 0.59" 15 3.50" 6 0.24" 401.57" 27.5 1.08" 145 5.71" ø0.18" 8-ø 4.5 through-hole ø 10 spot facing, 5 (d) ø0.39" 0.20" 4-M6, effective depth 10 0.39" 10 0.39" 35 1.38" 272 10.71" (16) (0.63") 706 27.80" 288 11.34" (16) (0.63") 4-M4, effective depth 6 0.24" 4-M4, effective depth 6 0.24" 10 0.39" 35 1.38" 0.39" 10 1.38" 35 21.5 0.85" 424 112 4.41" 221.5 8.72" 221.5 8.72" 132 5.20" 21.5 0.85" Inch MAIN MENU PRODUCTS APPLICATIONS INDEX SELECTION GUIDE High-speed Laser Scan Micrometers Unit: mm Built-in display controller LS-5000 Inch LS-5501 197 187 7.76" 7.36" 4.96" 126 7.09" 180 5.83" 148 9.06" 230 1.61" 41 Approx. 80 3.15" Separate display controller 1 0.04" LS-5001 37.3 1.47" 5.98" 5.51" 5.12" 152 140 130 (External mounting bracket) 35.4 1.39" Approx. 80 3.15" 116 4.57" 170 6.69" 99 3.90" Display unit LS-D501 Panel cutout Mounting bracket Panel thickness: 1.2 to 4.0 0.05" to 0.16" Mounting screw 173 min. 6.81" +1 0 5.87" 149 (Mounting 132 bracket 5.20" dimension) 125 124.5 4.90" 4.92" +0.04" 0 +1 0 156 4.17" 106 6.42" 163 5 0.20" A connection cable must be used. Select the cable according to your requirement. (for controller and scanning head) ø 6.8, cable length: 3 m 9.8' ø0.27" 40.5 1.59" 30 1.18" ø 15.5 ø0.61" Transmitter/receiver extension cable 38 1.50" ø 4.3, cable length: 3 m 9.8' ø0.17" ø 12 ø0.47" 1. 10m cable is available as option. 32.8' 159 min. 6.26" 49 1.93" Connection cable 1.26" 32 +0.04" 6.14" 0 1 Sensor head front surface protective cover (for LS-5121) Cable length Model 3 m 9.8' LS-C3 LS-C10 10 m 32.8' LS-C50 50 m 164.0' 154 6.06" 15 0.51" 38 1.50" ø0.47" ø 12 425