LS03 Series 3W, HIGH VOLTAGE DC-DC(AC-DC) CONVERTER LS----- are high efficiency green power modules with miniature packaging provided by Mornsun. The features of this series are: wide input voltage, DC and AC all in one, high efficiency, high reliability, low loss, safety isolation etc. They are widely used in industrial, office and civil equipments, as well as applications where no special requirement for EMC performance. It is recommended to add EMI suppression circuit or take measure to shield when there is strict requirement for EMC performance.
MODEL SELECTION
PRODUCT FEATURES 1. 2. 3. 4. 5. 6.
Wide input voltage:100 ~ 400VDC(85 ~ 264VAC) Over temperature protection and short circuit protection High efficiency, high density Low loss, green power Multiple models available Industrial level specifications
LS03-05B15S Special Mark Output Voltage Output Style Input Voltage Isolation Voltage Output Power Package Style Product Series
PRODUCT PROGRAM Model
Package
Power
Output (Vo1/Io1)
Ripple and Noise (TYP)
Efficiency (%) (TYP)
LS03-05B03S
1.65W
3.3V/500mA
LS03-05B05S
2.5W
5V/500mA
70
9V/330mA
75
LS03-05B09S
34.0X22.5X9.5mm
LS03-05B12S
3W
12V/250mA
50mV
100mV
70
78
LS03-05B15S
15V/200mA
78
LS03-05B24S
24V/125mA
78
INPUT SPECIFICATIONS Input voltage range
100~400VDC(85~264VAC)
Input current
40mA (TYP)
External input fuse(recommended)
0.5A/250V
OUTPUT SPECIFICATIONS Voltage set accuracy
±2%
Input variation
±0.5% (typ)
Load variation (10%~100%) Ripple & noise(p-p)
(20MHz Bandwidth)
±1% (typ) 100mV(typ)
Short circuit protection
Continuous, automatic resume
Over temperature protection
150°C (max)
Note: Ripple and Noise were measured by the method of anear measure(The details see the anear measure);
The copyright and authority for the interpretation of the products are reserved by Mornsun
Specifications subject to change without notice. LS03 A/0-2009 Page 1 of 4
COMMON SPECIFICATIONS Operating
-40°C ~ +85°C
Power derating
Temperature ranges
(above 55°C):
1.33% /°C
Storage:
-40°C ~ +105°C
Case temperature:
+90°C max
Humidity
85%(max)
Temperature coefficient
0.02%/°C
Switching frequency
100kHz(typ)
Efficiency
75%(typ)
I/O-isolation voltage
2000VAC/1Min
Leakage current
None
Case material
UL94V-0
Install
PCB
MTBF
>200,000h @25°C
INPUT VOLTAGE VS LOAD
TEMPERATURE VS LOAD Load(%)
Load(%)
100
100
80
80
60 40
60 70 85
100 110
340 240
400 264
-40 -20
Vdc Vac
55
85
Temperature( C)
TYPICAL EFFICIENCY CURVE LS03 DC input rated load efficiency cure
LS03 DC input efficiency cure
84
85 100VDC input efficiency 200VDC input efficiency 300VDC input efficiency 400VDC input efficiency
Efficiency(%)
75 70 65 60 55
82
LS03-05B03S efficiency(100%load) LS03-05B05S efficiency(100%load) LS03-05B09S efficiency(100%load) LS03-05B12S efficiency(100%load) LS03-05B15S efficiency(100%load) LS03-05B24S efficiency(100%load)
80 Efficiency (%)
80
78 76 74 72
50
70
45
68 66
40 10
20
30
40
50
60
70
80
100
90 100
150
200
250
300
350
400
Input voltage (VDC)
Load(%)
LS03 AC input rated load efficiency cure 84
84 80 76 72 68
85VAC input efficiency 110VAC input efficiency 120VAC input efficiency 220VAC input efficiency 230VAC input efficiency 240VAC input efficiency 264VAC input efficiency
64 60 56 52 48 44
LS03-05B03S efficiency(100%load) LS03-05B05S efficiency(100%load) LS03-05B09S efficiency(100%load) LS03-05B12S efficiency(100%load)
82 80 Efficiency(%)
Efficency (%)
LS03 AC input efficiency cure
78 76
LS03-05B15S efficiency(100%load) LS03-05B24S efficiency(100%load)
74 72
10 20 30 40 50 60 70 80 90 100 Load (%)
70 85
110
120
220
230
240
264
Input Voltage(VAC)
The copyright and authority for the interpretation of the products are reserved by Mornsun
Specifications subject to change without notice. LS03 A/0-2009 Page 2 of 4
STRUCTURE FIGURE 12
+Vin(L)
7
-Vin(N) C1 External Capacitor
1
Rectifier filter circuit
DC/DC Co nvertor
Rectificate
3
+Vo -Vo
Voltage sampling
+ 10
Co ntrl Circu it
Feedback loop
ANEAR MEASURE Connect Oscillograph Probe Copper sheet
Fuse
C1
C2
10
+
C3
Load
7 25.4mm
25.4mm
TYPICAL APPLICATIONS
F u se
12
+Vin
+ Vo C 2
1
C 3 Tv S R L
F u se
EM C F ilte r
12
L NF
MOV
+
MOV
3
+ C1
N
LS03 DC input typical application
C 3 Tv S R L
+
C4
-Vo
7
1
C5
C6
-V i n
+ Vo C 2
10 -Vo
7
3
LS03 AC input typical application
EXTERNAL CAPACITORS TYPICAL VALUE Output Voltage
C1
C2
C3
FUSE
TVS
3.3V P4KE6.8A
5V 9V
150uF/25V 0.1uF/50V (ceramic capacitor)
10uF/400V
12V 15V
0.5A/250V
P4KE12A P4KE20A
100uF/35V
24V
P4KE33A
Note: 1. Filtering capacitors C1, C2 are electrolytic capacitors, C1 is used in AC input, when input voltage is below 100VAC, the value of C1 is 22uF/400V. C2 is recommended to use high frequency and low impedance electrolytic capacitors. For capacitance and current of capacitor please refer to manufacture’s datasheet. Voltage derating of capacitor should be 80% or above. C3 is ceramic capacitor, it is used to filter high frequency noise. TVS is a recommended component to protect post-circuits (if converter fails). 2. If EMC performance is required, recommended to add “EMC filter” at the input end. C4: X capacitor, recommended parameter :0.1uF/275V C5,C6: Y capacitor, recommended parameter:220pF/2000V NF: Common-mode choke, recommended parameter: 10mH-30mH 3. MOV: pressure sensitive resistance, model 471KD05, is used to protect converter in lightning strike surge.
The copyright and authority for the interpretation of the products are reserved by Mornsun
Specifications subject to change without notice. LS03 A/0-2009 Page 3 of 4
OUTLINE DIMENSIONS & PIN CONNECTIONS RECOMMENDED FOOTPRINT
MECHANICAL DIMENSIONS SIP Pa cka ge 34.00 [1.339]
9.50 [0.374] 2.54 [0. 100 ]
3.00[0.118]
2 2.50 [0.866]
∅1.00 [∅ 0.039]
1
3
7
10
1
3
7
10
12
2.54 [0.100]
12
PACKAGING DIAGRAM 3.00 [0.118]
5.08 [0.200]
9.00 [0.354]
Note: Unit:mm[inch] General tolerances:±0.5mm[±0.020inch]
FOOTPRINT DETAILS Pin Function +Vo 1 3 -Vo 7 -Vin(N) 10 CAP 12 +Vin(L)
Inside box: L*W*H=165*155*40mm Outside box: L*W*H=425*175*160mm Packaging Quantity: Inside box: 10pcs, Outside box: 100pcs Note: Unit :mm[inch] General tolerances: ±0.50mm[±0.020inch]
Note: 1. All specifications measured at Ta=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise specified. 2. In this datasheet, all the test methods of indications are based on corporate standards.
The copyright and authority for the interpretation of the products are reserved by Mornsun
Specifications subject to change without notice. LS03 A/0-2009 Page 4 of 4