LS093HE
PQWRHSF0
Standard Single Zone Outdoor Unit (ODU)‐LSU093HE Indoor Unit (IDU)‐LSN093HE Operating Range: Outdoor Unit:
Performance: Cooling: Capacity (Btu/h) SEER EER
10,500 13.0 9.5
Heating: 10,500 7.8
HSPF ‐ Heating Seasonal Performance Factor Cooling Nominal Test Conditions: Indoor: 80°F DB/67°F WB Outdoor: 95°F DB/75°F WB
Heating Nominal Test Conditions: Indoor: 70°F DB/60°F WB Outdoor: 47°F DB/43°F WB
115/60/1
MOP (A)
20
MCA (A)
14.3
Cooling Rated Amps (A) Heating Rated Amps (A) Compressor (A)
9.5 9.5 10.5 0.2
Fan Motor (A) MOP ‐ Maximum Overcurrent Protection MCA ‐ Minimum Circuit Ampacity
Indoor Unit: Power Supply
36V DC
Cooling Power Input (kW) Heating Power Input (kW)
1.1 1.1
Piping:
64‐90 61‐86
Unit Data: Refrigerant Type Refrigerant Control Refrigerant Charge (lbs)
R410A Check Valve & Capillary Tube 2.05 48 41/36/34 72.8 73.4 20.5 23.1
ODU Net Weight (lbs) ODU Shipping Weight (lbs) IDU Net Weight IDU Shipping Weight (lbs) Heat Exchanger Coating Communication Cable (No x AWG)⁴
GoldFin™ 4 x 18
Fan: ODU Type IDU Type Fan Speeds (Fan/Cooling/Heating)
Propeller Cross Flow 3/4/3
Quantity (ODU + IDU)
1 + 1
Brushless Digitally Controlled/Direct Motor/Drive ODU Max Air Flow Rate (CFM) 847 330/280/230 IDU Max Air Flow H/M/L (CFM) 3.0
Dehumidification (pts/hr)
Liquid Line (in, OD)
1/4
Vapor Line (in, OD) Additional Refrigerant (oz/ft)
1/2 0.22
Max Pipe Length (ft)²
49
Piping Length (no add'l refrigerant, ft) Max Elevation (ft)
25 23
Features: •4 Fan speeds •24‐Hour on/off mer •Auto opera on •Auto restart •Auto sleep mode •Built‐in low ambient standard, down to 14°F (cooling mode) •Chaos wind •Defrost control
Indoor Unit:
ODU Sound Pressure Max (±3 dB(A))³ IDU Sound Pressure (H/M/L) (±3 dB(A))³
Electrical: Outdoor Unit: Power Supply (V¹/Hz/Ø)
14‐115 34‐75
Cooling (°F DB) Heating (°F DB)
SEER ‐ Seasonal Energy Efficiency Ratio EER ‐ Energy Efficiency Ratio
Capacity (Btu/h) HSPF
Cooling (°F DB) Heating (°F DB)
•Evaporator frost control •Fan mode •Jet cool •Manual power switch •Plasma air purifying system •Temperature display on indoor unit •Ultra‐quiet opera on
Notes: 1.Acceptable opera ng voltage: 187V‐253V. 2.Piping lengths are equivalent. 3.Sound Pressure levels are tested in an anechoic chamber under ISO Standard 1996. 4.All communica on cable to be minimum 18 AWG, 2‐conductor, stranded, shielded and must comply with applicable local and national code. 5.See Engineering Manual for sensible and latent capaci es. 6.Power wiring cable size must comply with the applicable local and na onal code. 7.The indoor unit comes with a dry helium charge. 8.This data is rated 0 above sea level, with 24.6 of refrigerant line and a 0 level difference between outdoor and indoor units. 9.Must follow installa on instruc ons in the applicable LG installa on manual.
Standard Features: •Limited Five Year Compressor Warranty •Limited Two Year Func onal Parts Warranty
For continual product development, LG reserves the right to change specifications without notice. LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com
DFS‐SB‐AA‐015‐US 012M18
Page 1 of 3
Job Name/Location:
Outdoor Unit (ODU)‐LSU093HE
Tag #:
Standard Single Zone
Date: PO No.:
For continual product development, LG reserves the right to change specifications without notice. LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com
DFS‐SB‐AA‐015‐US 012M18
Page 2 of 3
Job Name/Location:
Indoor Unit (IDU)‐LSN093HE
Tag #:
Standard Single Zone
Date: PO No.:
For continual product development, LG reserves the right to change specifications without notice. LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com
DFS‐SB‐AA‐015‐US 012M18
Page 3 of 3