Preview only show first 10 pages with watermark. For full document please download

Lse2 300

   EMBED


Share

Transcript

LSE 2-300 2V300AH 2V1000AH LSE Series SLA Battery Range Summary By combining the service life reliability of a flooded battery with the performance energy density of a valve-regulated battery, BSB created a true long service life VRLA battery - the LSE range. The range offers 20 years design life with very good cycling capabilities. This range is highly suited to telecom, UPS, renewable energy system, power station and similar applications. Application · Control Equipment · Medical Equipment · Emergency Power System · Power Plant · Cable Television · Communication Equipment · Security System · UPS General Features · Extra long life service design. · Non-Spillable construction design. · ABS containers and covers(UL94 V0, optional). · Safety valve installation for explosion proof. · Higher safety & reliable construction. · Exceptional deep discharge recovery performance. · Low self discharge characteristic. · Flexible design for multiple installation positions. 7mm (0.28inch) 20mm (0.79inch) M8mm (0.31inch) Construction Positive ...... Negative ...... Container ...... ...... Cover Sealant ...... Safety valve Terminal Separator Electrolyte Lead dioxide Lead ABS ABS Epoxy Resin ...... ...... ...... ...... Terminal Dimensions 184.5mm(7.26inch) 102mm(4.02inch) 372mm(14.6inch) 123mm(4.84inch) 360.5mm(14.2inch) EPDR Copper AGM Sulfuric acid Battery Model LSE2-300 Designed Floating Life Capacity(20oC) 20 Years 10HR(30.0A,1.80V) 20HR(15.8A,1.80V) 316AH Length Dimensions 123mm(4.84inch) 5HR(51.5A,1.75V) 300AH 257AH 188AH Width Height Total Height 184.5mm(7.26inch) Approx. Weight 360.5mm(14.2inch) Internal Resistance Self Discharge < 3% of capacity declined per month at (20oC) Charge Voltage(20oC) 372mm(14.6inch) 19 Kg (41.9 lbs) Full charged at 20oC :0.00047 Ohm Capacity Affected by Temp.(10HR) 1HR(188A,1.60V) 40oC 20oC 0oC -15oC 109% 100% 85% 65% Cycle use Float use o 2.35V-2.40V(-5mV/ C), max. Current: 75A Page 1 of 2 2.25-2.29V(-3mV/ oC) LSE 2-300 2V300AH 2V1000AH Charge Voltage Current o Constant Charge at 0.25CA-2.35V (20oC) (CA) (V/Cell) 100 0.25 Charge Capacity Charge Voltage 2.35 80 2.17 100%Discharge 0.20 60 2.00 50%Discharge 0.15 40 0.10 20 1.83 0.05 0 Discharge Characteristic (20 C) Charge Characteristic Charge Current 0 0 2 4 6 8 10 Discharge Voltage (V/Cell) (%) 120 Charge Charge Capacity LSE Series SLA Battery 2.17 2.00 1.83 0.05CA 0.25CA 0.1CA 1.67 1.60 0.6CA 30 60 1.33 0 12 2 6 12 3 Min Time(hour) 10 Hour 20 Self Discharge Characteristics Relationship of OCV and state of charge 110 105 2.25 2.17 Capacity (%) Battery Voltage (V/Cell) 1CA 2.08 2.00 100 95 90 85 80 75 70 65 60 55 50 1.92 40oC 45 1.83 0 10 20 30 40 50 60 70 80 90 100 40 0 1 2 o 20 C o 30 C 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Storage time:months Remained Capacity(%) Constant current discharge ratings-amperes at 20oC F .V /T im e 5 M IN 1 0 M IN 1 5 M IN 3 0 M IN 1HR 3HR 5HR 10 H R 20HR 1 .6 0V 1172 729 550 335 188 9 3.6 5 4 .9 3 2 .0 1 7 .5 1 .6 7V 1100 692 529 321 185 9 0.0 5 3 .8 3 1 .7 1 6 .9 1 .7 0V 1008 667 517 292 180 8 4.0 5 2 .6 3 1 .6 1 6 .6 1 .7 5V 988 646 500 277 171 8 1.2 5 1 .5 3 1 .1 1 6 .2 1 .8 0V 884 617 454 257 160 7 8.0 4 8 .4 3 0 .0 1 5 .8 1 .8 5V 780 588 408 236 149 7 5.2 4 5 .3 3 0 .3 1 5 .3 Constant power discharge ratings-watts at 20oC F .V /T im e 5 M IN 10 M IN 1 5M IN 3 0 M IN 1H R 3HR 5HR 1 0H R 20HR 1. 6 0 V 1. 6 7 V 1. 7 0 V 2056 1984 1868 1317 1283 1271 1004 992 983 604 592 554 339 337 330 166 161 154 9 1 .8 9 1 .4 9 0 .3 64 . 0 63 . 6 63 . 2 3 4 .9 3 3 .7 3 3 .3 1. 7 5 V 1. 8 0 V 1. 8 5 V 1800 1720 1560 1267 1248 1184 975 904 820 538 513 480 325 306 288 150 146 141 8 9 .5 8 6 .7 8 3 .9 62 . 4 61 . 6 60 . 8 3 2 .4 3 1 .6 3 0 .4 ISO9001 COPYRIGHT BSB POWER COMPANY LIMITED Page 2 of 2 (Updated: 1-Nov-2010)