LSE 2-3000 2V3000Ah 2V1000AH LSE Series SLA Battery Range Summary By combining the service life reliability of a flooded battery with the performance energy density of a valve-regulated battery, BSB created a true long service life VRLA battery - the LSE range. The range offers 20 years design life with very good cycling capabilities. This range is highly suited to telecom, UPS, renewable energy system, power station and similar applications. Application · Cable Television · Communication Equipment · Security System · UPS · Control Equipment · Medical Equipment · Emergency Power System · Power Plant General Features · Extra long life service design. · Non-Spillable construction design. · ABS containers and covers(UL94 V0, optional). · Safety valve installation for explosion proof. · Higher safety & reliable construction. · Exceptional deep discharge recovery performance. · Low self discharge characteristic. · Flexible design for multiple installation positions. 7mm (0.28inch) 20mm (0.79inch) M8mm (0.31inch) Construction Positive ...... Negative ...... Container ...... ...... Cover Sealant ...... Lead dioxide Lead ABS ABS Epoxy Resin Safety valve Terminal Separator Electrolyte ...... ...... ...... ...... EPDR Copper AGM Sulfuric acid 362mm[14.3inch] 363mm[14.3inch] 374mm[14.7inch] 496mm[19.5inch] Terminal Dimensions Battery Model LSE2-3000 Designed Floating Life Capacity(20oC) 20 Years 20HR(158A,1.80V) 10HR(300A,1.80V) 3160Ah Dimensions 3000Ah 2575Ah Width Height Total Height 496mm(19.5inch) 363mm(14.3inch) 362mm(14.3inch) 374mm(14.7inch) 1876Ah 175Kg (386 lbs) Full charged at 20oC :0.0001 Ohm Internal Resistance < 3% of capacity declined per month at (20oC) Self Discharge Charge Voltage(20oC) 1HR(1876A,1.60V) Length Approx. Weight Capacity Affected by Temp.(10HR) 5HR(515A,1.75V) 40oC 20oC 0oC -15oC 109% 100% 85% 65% Cycle use Float use o 2.35V-2.40V(-5mV/ C), max. Current: 750A Page 1 of 2 2.25-2.29V(-3mV/ oC) LSE 2-3000 2V3000Ah 2V1000AH Charge Voltage Current o Constant Charge at 0.25CA-2.35V (20oC) (CA) (V/Cell) 100 0.25 Charge Capacity Charge Voltage 2.35 80 2.17 100%Discharge 0.20 60 2.00 50%Discharge 0.15 40 0.10 20 1.83 0.05 0 Discharge Characteristic (20 C) Charge Characteristic Charge Current 0 0 2 4 6 8 10 Discharge Voltage (V/Cell) (%) 120 Charge Charge Capacity LSE Series SLA Battery 2.17 2.00 1.83 0.05CA 0.25CA 0.1CA 1.67 1.60 0.6CA 30 60 1.33 0 12 2 6 12 3 Min Time(hour) 10 Hour 20 Self Discharge Characteristics Relationship of OCV and state of charge 110 105 2.25 2.17 Capacity (%) Battery Voltage (V/Cell) 1CA 2.08 2.00 100 95 90 85 80 75 70 65 60 55 50 1.92 45 1.83 0 10 20 30 40 50 60 70 80 90 100 40 0 40oC 1 2 o 20 C o 30 C 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Storage time:months Remained Capacity(%) Constant current discharge ratings-amperes at 20oC F .V /T im e 5m in 1 0 m in 1 5 m in 30 m in 1h 3h 5h 1 0h 20h 1. 6 0 V 1. 6 7 V 1. 7 0 V 1 17 2 0 1 10 0 0 1 00 8 0 7292 6917 6667 5500 5292 5167 33 5 4 32 0 8 29 1 7 1 8 76 1 8 52 1 7 95 936 900 840 5 72 5 60 5 48 313 311 309 175 169 166 1. 7 5 V 9880 6458 5000 27 7 1 1 7 11 812 5 15 305 162 1. 8 0 V 1. 8 5 V 8840 7800 6167 5875 4542 4083 25 6 7 23 6 3 1 6 02 1 4 92 780 752 5 04 4 72 300 297 158 153 Constant power discharge ratings-watts at 20oC F .V /T im e 5m in 1 0 m in 1 5 m in 30 m in 1h 3h 5h 1 0h 20h 1. 6 0 V 1. 6 7 V 1. 7 0 V 2 05 6 0 1 98 4 0 1 88 0 0 1 3 16 7 1 2 83 3 1 2 70 8 10042 9917 9833 60 4 2 59 1 7 55 4 2 3 8 48 3 8 24 3 7 52 1660 1608 1536 9 67 9 63 9 50 640 636 632 353 340 336 1. 7 5 V 1. 8 0 V 1 80 0 0 1 72 0 0 1 2 66 7 1 2 48 0 9750 9042 53 7 5 51 2 5 3 6 88 3 4 76 1500 1456 9 42 9 13 624 616 328 319 1. 8 5 V 1 56 0 0 1 1 84 0 8200 48 0 0 3 2 68 1412 8 83 608 307 ISO9001 COPYRIGHT BSB POWER COMPANY LIMITED Page 2 of 2 (Updated: 1-Nov-2010)