Transcript
LSG2-150
2V150Ah
Gel SLA Battery Range Summary By combining the newly developed nano gel electrolyte with up-to-date AGM structures, BSB created the innovative LSG range of batteries. The range offers 20 years design life with very high deep cycling capabilities. This range is highy suited to telecom outdoor applications, renewable energy system and other harsh environment applications.
Application Correspondence exchange and transmission system Mobile communication system Power plant and power transformer system Radio and broadcasting station Navigation and signaling system
Emergency power system UPS Other spare, circulatory system
General Features Sealed and maintenance free operation. Non-Spillable construction design. ABS containers and covers (UL94 V0, optional). Safety valve installation for explosion proof. High quality and high reliability. Exceptional deep discharge recovery performance. Low self discharge characteristic. Flexible design for multiple installation positions.
7mm (0.28inch)
20mm (0.79inch)
M8mm (0.31inch)
Construction Safety valve Terminal Separator Electrolyte
Lead dioxide Lead ABS ABS Epoxy Resin
...... ...... ...... ......
EPDR Copper AGM Acid with gel
Terminal Dimensions
221mm(8.70inch)
Positive ...... Negative ...... Container ...... ...... Cover Sealant ......
172mm(6.77inch)
Battery Model
LSG2-150
Designed Floating Life
20 Years
Capacity(20oC)
Dimensions
20HR(7.94A,1.80V)
10HR(15A,1.80V)
5HR(25.6A,1.75V)
159Ah
150Ah
128Ah
Length
Width
Height
Total Height
172mm(6.77inch)
102mm(4.02inch)
206mm(8.11inch)
221mm(8.70inch)
Approx. Weight
94.1Ah
8.7Kg (19.2 lbs)
Internal Resistance
Full charged at 20oC :0.00082 Ohm
Self Discharge
< 3% of capacity declined per month at (20oC)
Capacity Affected by Temp.(10HR) Charge Voltage(20oC)
1HR(94.1A,1.60V)
40oC
20oC
0oC
-15oC
109%
100%
85%
65%
Cycle use
Float use
2.35V-2.40V(-5mV/ oC), max. Current: 37.5A
Page 1 of 2
2.25-2.29V(-3mV/ oC)
LSG2-150
2V150Ah
Charge Voltage
(CA) (V/Cell)
(%) 120 100 80
0.25
o
Constant Charge at 0.25CA-2.35V (20 C) Charge Capacity
Charge Voltage
2.35
2.17 100%Discharge
0.20
60
2.00
50%Discharge
0.15
40
0.10 20
1.83
0.05
0
0
Discharge Characteristic (20oC)
Charge Characteristic
Charge Current
0
2
4
6
8
10
Discharge Voltage (V/Cell)
Current
Charge
Charge Capacity
Gel SLA Battery
2.17 2.00 1.83 0.25CA 0.1CA 0.05CA
1.67 1.60
3CA
2CA
1CA
6
12
30
1.33 0
12
2
60
3
Min
Time(hour)
10 Hour
20
Self Discharge Characteristics
Relationship of OCV and state of charge 2.25
110 105
2.17
100 95 90
Capacity (%)
Battery Voltage (V/Cell)
0.6CA
2.08
2.00
85 80 75 70 65 60 55 50
1.92
1.83
o
0
10
20
30
40
50
60
70
80
90
100
40 0
1
2
20oC
o
40 C
45
30 C 3 4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20
Storage time:months
Remained Capacity(%)
Constant current discharge ratings - amperes at 20 C
F.V/ Tim e 1.60V 1.67V 1.70V 1.75V 1.80V 1.85V
5MI N 525 473 449 399 360 273
10MI N 360 329 317 293 272 224
15MI N 263 255 246 233 222 192
30MIN 158 153 150 147 143 131
1HR 94.1 93.9 93.6 92.6 91.5 90.5
3HR 41.0 40.8 40.7 40.5 40.4 40.2
5HR 26.2 26.0 25.8 25.6 25.4 25.2
10HR 15.9 15.7 15.5 15.3 15.0 14.7
20HR 8.30 8.27 8.25 8.23 7.94 7.47
30MIN 297 291 284 276 269 246
1HR 185 179 174 173 170 168
3HR 78.6 78.2 78.0 77.4 76.4 76.1
5HR 49.8 49.5 19.3 49.0 48.5 47.8
10HR 31.8 31.3 31.1 30.6 30.0 29.5
20HR 16.6 16.5 16.3 16.1 15.9 14.9
Constant power discharge ratings - watts at 20 C
F.V/ Tim e 1.60V 1.67V 1.70V 1.75V 1.80V 1.85V
5MI N 866 821 767 714 641 513
10MI N 597 590 575 537 500 414
15MI N 465 461 453 426 401 350
ISO9001
COPYRIGHT BSB POWER COMPANY LIMITED Page 2 of 2
(Updated: 1-Nov-2010)