LSG2-150 2V150Ah Gel SLA Battery Range Summary By combining the newly developed nano gel electrolyte with up-to-date AGM structures, BSB created the innovative LSG range of batteries. The range offers 20 years design life with very high deep cycling capabilities. This range is highy suited to telecom outdoor applications, renewable energy system and other harsh environment applications. Application Correspondence exchange and transmission system Mobile communication system Power plant and power transformer system Radio and broadcasting station Navigation and signaling system Emergency power system UPS Other spare, circulatory system General Features Sealed and maintenance free operation. Non-Spillable construction design. ABS containers and covers (UL94 V0, optional). Safety valve installation for explosion proof. High quality and high reliability. Exceptional deep discharge recovery performance. Low self discharge characteristic. Flexible design for multiple installation positions. 7mm (0.28inch) 20mm (0.79inch) M8mm (0.31inch) Construction Safety valve Terminal Separator Electrolyte Lead dioxide Lead ABS ABS Epoxy Resin ...... ...... ...... ...... EPDR Copper AGM Acid with gel Terminal Dimensions 221mm(8.70inch) Positive ...... Negative ...... Container ...... ...... Cover Sealant ...... 172mm(6.77inch) Battery Model LSG2-150 Designed Floating Life 20 Years Capacity(20oC) Dimensions 20HR(7.94A,1.80V) 10HR(15A,1.80V) 5HR(25.6A,1.75V) 159Ah 150Ah 128Ah Length Width Height Total Height 172mm(6.77inch) 102mm(4.02inch) 206mm(8.11inch) 221mm(8.70inch) Approx. Weight 94.1Ah 8.7Kg (19.2 lbs) Internal Resistance Full charged at 20oC :0.00082 Ohm Self Discharge < 3% of capacity declined per month at (20oC) Capacity Affected by Temp.(10HR) Charge Voltage(20oC) 1HR(94.1A,1.60V) 40oC 20oC 0oC -15oC 109% 100% 85% 65% Cycle use Float use 2.35V-2.40V(-5mV/ oC), max. Current: 37.5A Page 1 of 2 2.25-2.29V(-3mV/ oC) LSG2-150 2V150Ah Charge Voltage (CA) (V/Cell) (%) 120 100 80 0.25 o Constant Charge at 0.25CA-2.35V (20 C) Charge Capacity Charge Voltage 2.35 2.17 100%Discharge 0.20 60 2.00 50%Discharge 0.15 40 0.10 20 1.83 0.05 0 0 Discharge Characteristic (20oC) Charge Characteristic Charge Current 0 2 4 6 8 10 Discharge Voltage (V/Cell) Current Charge Charge Capacity Gel SLA Battery 2.17 2.00 1.83 0.25CA 0.1CA 0.05CA 1.67 1.60 3CA 2CA 1CA 6 12 30 1.33 0 12 2 60 3 Min Time(hour) 10 Hour 20 Self Discharge Characteristics Relationship of OCV and state of charge 2.25 110 105 2.17 100 95 90 Capacity (%) Battery Voltage (V/Cell) 0.6CA 2.08 2.00 85 80 75 70 65 60 55 50 1.92 1.83 o 0 10 20 30 40 50 60 70 80 90 100 40 0 1 2 20oC o 40 C 45 30 C 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Storage time:months Remained Capacity(%) Constant current discharge ratings - amperes at 20 C F.V/ Tim e 1.60V 1.67V 1.70V 1.75V 1.80V 1.85V 5MI N 525 473 449 399 360 273 10MI N 360 329 317 293 272 224 15MI N 263 255 246 233 222 192 30MIN 158 153 150 147 143 131 1HR 94.1 93.9 93.6 92.6 91.5 90.5 3HR 41.0 40.8 40.7 40.5 40.4 40.2 5HR 26.2 26.0 25.8 25.6 25.4 25.2 10HR 15.9 15.7 15.5 15.3 15.0 14.7 20HR 8.30 8.27 8.25 8.23 7.94 7.47 30MIN 297 291 284 276 269 246 1HR 185 179 174 173 170 168 3HR 78.6 78.2 78.0 77.4 76.4 76.1 5HR 49.8 49.5 19.3 49.0 48.5 47.8 10HR 31.8 31.3 31.1 30.6 30.0 29.5 20HR 16.6 16.5 16.3 16.1 15.9 14.9 Constant power discharge ratings - watts at 20 C F.V/ Tim e 1.60V 1.67V 1.70V 1.75V 1.80V 1.85V 5MI N 866 821 767 714 641 513 10MI N 597 590 575 537 500 414 15MI N 465 461 453 426 401 350 ISO9001 COPYRIGHT BSB POWER COMPANY LIMITED Page 2 of 2 (Updated: 1-Nov-2010)