Transcript
LSG2-600
2V600Ah
Gel SLA Battery Range Summary By combining the newly developed nano gel electrolyte with up-to-date AGM structures, BSB created the innovative LSG range of batteries. The range offers 20 years design life with very high deep cycling capabilities. This range is highy suited to telecom outdoor applications, renewable energy system and other harsh environment applications.
Application Emergency power system UPS Other spare, circulatory system
Correspondence exchange and transmission system Mobile communication system Power plant and power transformer system Radio and broadcasting station Navigation and signaling system
General Features Sealed and maintenance free operation. Non-Spillable construction design. ABS containers and covers (UL94 V0, optional). Safety valve installation for explosion proof. High quality and high reliability. Exceptional deep discharge recovery performance. Low self discharge characteristic. Flexible design for multiple installation positions.
7mm (0.28inch)
20mm (0.79inch)
M8mm (0.31inch)
Construction Positive ...... Negative ...... Container ...... ...... Cover Sealant ......
Lead dioxide Lead ABS ABS Epoxy Resin
Safety valve Terminal Separator Electrolyte
...... ...... ...... ......
EPDR Copper AGM Acid with gel
223mm(8.78inch)
Terminal Dimensions
184.5mm(7.26inch)
102mm(4.02inch)
199mm(7.83inch)
372mm(14.6inch)
360.5mm(14.2inch)
140.5mm(5.53inch)
Battery Model
LSG2-600
Designed Floating Life Capacity(20oC)
20 Years 10HR(60.0A,1.80V)
20HR(31.8A,1.80V) 636Ah Length
Dimensions
223mm(8.78inch)
5HR(102A,1.75V)
600Ah
510Ah
375Ah
Width
Height
Total Height
184.5mm(7.26inch)
Approx. Weight
360.5mm(14.2inch)
Internal Resistance Self Discharge
< 3% of capacity declined per month at (20oC)
Charge Voltage(20oC)
372mm(14.6inch)
36Kg (79.4 lbs) Full charged at 20oC :0.00028 Ohm
Capacity Affected by Temp.(10HR)
1HR(375A,1.60V)
40oC
20oC
0oC
-15oC
109%
100%
85%
65%
Cycle use
Float use
o
2.35V-2.40V(-5mV/ C), max. Current: 150A
Page 1 of 2
2.25-2.29V(-3mV/ oC)
LSG2-600
2V600Ah
Charge Voltage
(CA) (V/Cell)
(%) 120
2.35 100 80
0.25
o
Constant Charge at 0.25CA-2.35V (20 C) Charge Capacity
Charge Voltage
2.17 100%Discharge
0.20
60
2.00
50%Discharge
0.15
40
0.10 20
1.83
0.05
0
0
Discharge Characteristic (20oC)
Charge Characteristic
Charge Current
0
2
4
6
8
10
Discharge Voltage (V/Cell)
Current
Charge
Charge Capacity
Gel SLA Battery
2.17 2.00 1.83 0.25CA 0.1CA 0.05CA
1.67 1.60
3CA
2CA
1CA
6
12
30
1.33 0
12
2
60
3
Min
Time(hour)
10 Hour
20
Self Discharge Characteristics
Relationship of OCV and state of charge 2.25
110 105
2.17
100 95 90
Capacity (%)
Battery Voltage (V/Cell)
0.6CA
2.08
2.00
85 80 75 70 65 60 55 50
1.92
1.83
o
0
10
20
30
40
50
60
70
80
90
100
40 0
1
2
20oC
o
40 C
45
30 C 3 4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20
Storage time:months
Remained Capacity(%)
Constant current discharge ratings-amperes at 20oC F .V /T im e
5 M IN
1 0 M IN
1 5 M IN
3 0 M IN
1HR
3HR
5HR
10 H R
20HR
1 .6 0V
2344
1458
1100
671
375
1 87
109
6 2 .7
3 5 .4
1 .6 7V
2200
1383
1058
642
370
1 80
106
6 2 .1
3 4 .1
1 .7 0V
2016
1333
1033
583
359
1 68
104
6 1 .9
3 3 .6
1 .7 5V
1976
1292
1000
554
342
1 62
102
6 1 .0
3 2 .7
1 .8 0V
1768
1233
908
513
320
1 56
9 5 .8
6 0 .0
3 1 .8
1 .8 5V
1560
1175
817
473
298
1 50
8 9 .7
5 9 .4
3 0 .9
Constant power discharge ratings-watts at 20oC F .V /T im e
5 M IN
1 0 M IN
1 5 M IN
3 0 M IN
1HR
3HR
5HR
10 H R
20HR
1 .6 0V
4112
2633
2008
1208
677
3 32
184
125
7 0 .6
1 .6 7V
3968
2567
1983
1183
673
3 22
183
125
6 8 .0
1 .7 0V
3736
2542
1967
1108
660
3 07
181
124
6 7 .2
1 .7 5V
3760
2533
1950
1075
649
3 00
179
122
6 5 .5
1 .8 0V
3440
2496
1808
1025
612
2 91
173
121
6 3 .8
1 .8 5V
3120
2368
1640
960
575
2 82
168
119
6 1 .3
ISO9001
COPYRIGHT BSB POWER COMPANY LIMITED Page 2 of 2
(Updated: 1-Nov-2010)