Preview only show first 10 pages with watermark. For full document please download

Ltc-adss-30-48f4x12_conf114918

   EMBED


Share

Transcript

Fibre optic cable LTC ADSS-30 CONF114918 Commercial information Article class Serie Type Description Nett Weight Marking Ordercode Specifications Unit Fibre optic cable LTC ADSS-30 48x SM G.657.A1 (4x12) 70 kg/Km UPC Romania ACE- TKF LTC ADSS 48x SM G.657.A1 (4x12) A-DQ(ZN)2Y 77697 {Batch} {Year} {Length} EAN code Specifications Unit CONF114918 m Construction Specifications Unit Cable type Fibre type Optical fibre standard Number of fibres Number of fibres per optical element Number of cores Optical element Cable metal free Number of layers Strip method Strain relief Type of strain relief Material outer sheath Colour outer sheath Outer diameter approx. ADSS Single mode ITU-T G.657.A1 48 12 4 Loose tube, gel filled Yes 1 Layer 2 Rip cords Yes Aramid fibre HDPE Black 9.7 mm Characteristics for use Specifications Unit Application Technical characteristics Standardization Test procedures Longitudinal water blocking Longitudinal watertight construction Installation temperature Operation temperature range Transportation and storage temperature UV resistant Mechanical characteristics Tensile load short term (Tm) Tensile load Long Term (Tl) Maximum operational tension (MOT) Maximum allowable tension (MAT) Min. bending radius after installation Min. bending radius during installation Crush resistance acc. meth.E3A Impact strength Copyright (c) TKF, 1/21/2016 Subject to technical alterations BV Twentsche Kabelfabriek Spinnerstraat 15 - Postbus 6 - 74800 AA Haaksbergen - Nederland Tel: +31 (0)53 573 22 55 - Fax: +31 (0)53 573 21 85 - [email protected] - www.tkf.nl Outside Specifications Unit EN IEC 60794-3-20 IEC 60794-1-2 Yes Super Absorbing Polymer -5 / 50 ° C -40 / 70 ° C -40 / 70 ° C Yes Specifications Unit 2600 1800 1800 3000 145 190 1500 5 N N N N mm mm N/dm J Page 1/2  Fibre optic cable LTC ADSS-30 CONF114918 Mechanical characteristics Specifications Unit Striking surface radius Torsion resistance 10 mm 180 °/m Optical characteristics Specifications Unit Attenuation @ 1310 nm Attenuation @ 1550 nm Attenuation @ 1625 nm Other characteristics/features Halogen free (acc. EN 50267-2-2) Cross sectional area Effective E-modulus Effective CTE Copyright (c) TKF, 1/21/2016 Subject to technical alterations BV Twentsche Kabelfabriek Spinnerstraat 15 - Postbus 6 - 74800 AA Haaksbergen - Nederland Tel: +31 (0)53 573 22 55 - Fax: +31 (0)53 573 21 85 - [email protected] - www.tkf.nl 0.36 0.22 0.25 dB/km dB/km dB/km Specifications Unit Yes 74 3.9 29 mm² GPa 10^-6/°C Page 2/2