Preview only show first 10 pages with watermark. For full document please download

Luh Series : Wall Or Ceiling Mount Horizontal Unit Heater

   EMBED


Share

Transcript

WALL OR CEILING MOUNT HORIZONTAL UNIT HEATER LUH Series MADE IN USA 456 $ U Rugged, Premium Quality U 2.6 to 45 kW U 208, 240, 277, 480V, 1 & 3 Phase U 8,900 to 153,600 BTU/hr U Meets UL, NEC & OSHA Requirements U No Venting Necessary U Built-In Power Controls Basic Unit Type LUH self-contained heaters provide quiet, reliable fan-forced heating in all types of commercial and industrial applications. APPLICATIONS UShipping and Receiving Areas UPrimary & Supplementary Heating UDual System Heaters USpot Heating UEntryway Air Curtain Heating UProvides Heating for: Pump Houses, Power Generating Stations, Aircraft Hangers, Factories, Garages & Warehouses APPLICATION TIPS Small rooms can be heated by one unit heater. Where two walls are exposed, heater should be mounted as shown. Larger rooms require multi-unit installations. Number and capacity of units will be determined by volume of building and square feet of floor area to be heated. Arrange units to provide perimeter air circulation. To prevent air stratification, the total CFM capacity of all units should circulate the room air volume at least 3 times per hour. Unit heaters should be located so their air streams wipe exposed walls without blowing directly at them. In multiple unit heater installations, it is good practice to locate units so each unit supports the air stream from another, thus setting up a circulatory air movement within the space. In warehouse type applications, where maintaining minimum temperature is the basic requirement, then one or more large unit heaters can be used in order to reduce initial installation expense. Individual spaces. For individual spaces, total heating capacity is calculated in the conventional way, using formulas in the ASHRAE “Guide” or those found in the National Electric Manufacturer’s Assn. (NEMA) handbook. Pedestrian entryways. When heating capacity for a pedestrian entry is not known, a “rule of thumb” of 3000-5000 watts per door is often applied. The smaller figure is applied to a low traffic single-door entry or a large multiple-door entry, and the larger figure to a high traffic single-door entry. Unit heaters are frequently used to combat cold air inrush when L-3 loading dock doors are opened. For such applications, one or more units should be arranged to blow warm air across the opening, not toward it. OPTIONAL FEATURES (FACTORY INSTALLED OF FIELD INSTALLATION KITS) Summer Fan Switch Kit: Field installable for circulating warm stratified air. Available for all models. Thermostat Kit: Field installable on all models. Range 40 to 90°F. Power Disconnect Kit: Field installable switch enables power to be disconnected while servicing heater. 40, 80, and 100 Amp models available. Mounts on back of heater. Ceiling & Wall Mounting Bracket CAUTION AND WARNING! Fire and electrical shock may result if products are used improperly or installed or used by non-qualified personnel. See inside back cover for additional warning. FEATURES No external contactors are necessary. No external contactors are needed; integral, heavy-duty, 3pole, magnetic contactors are standard on all heaters with the exception of the 2.6 kW, 4kW and 5kW single-phase models. (They’re optional on these heaters. Contact OMEGALUX®.) The 5kW and smaller units can be remotely controlled direct by an OMEGALUX line voltage wall thermostat such as the WR series (see page L-10). Built-in fuse protection...no need for external fusing. All Horizontal Unit Heaters having a total draw of 48 amperes or more have electrically balanced, sub-divided circuits, each with fuse protection (no external fusing is necessary; reduces installation costs). Fuse compartment is located on the left side of the heater unit. A latched hinged door affords easy access. Internal 24V or 120V control transformer. All models can be equipped with low voltage control transformer to eliminate the need for an external control source. Contact OMEGALUX. These transformers are standard on all 277 and 480 volt models, supplying 120 volt contactor holding coils. Die-formed cabinet. Cabinet is heavy,18 gauge steel; die formed and welded. No sharp edges. It’s given a phosphate undercoat for corrosion resistance in industrial atmospheres. Finished is neutral grey, baked enamel. Self-contained thermostats eliminate installation of wall thermostats. Any model (through 25 kW) can be equipped with a “built-in” field installed Thermostat Kit, LUH-TK, to eliminate the use of a wall type thermostat and thermostat wiring. (Internal thermostats can be factory installed on any size unit, contact OMEGALUX.) LUH self-contained thermostats have a temperature range of 40°F to 90°F. If wall thermostats are desired, OMEGALUX WR series is recommended, page L-10. Fan-only operation. A fan-only operation (optional) is available by means of a built-in switch or by external control. Contact OMEGALUX. Individually adjustable discharge louvers direct air flow. Sub-divided Circuits with Individual Fuse Protection: Standard on all heaters with a total current draw of 48 Amps or greater. The fuse compartment is conveniently located for easy access. Integral 120V Control Transformer: Standard on all 480V models, eliminates the need for an external control source (24V optional). Heavy Duty Magnetic Contactors: Standard on all models. Thermal Cutouts: Open the control circuit and disconnect power to the heating elements if overheating occurs. Automatic reset allows the control circuit to reclose and restore power when temperature returns to normal. Field Convertible: Combination 208/240V and 1 or 3 phase operation through 10 kW. Mounting Configurations: Recessed welded fasteners on top of the heater cabinet are internally threaded for suspension of unit with threaded rods. Ceiling and Universal Wall Swivel brackets are optional. The ceiling bracket lets you mount heater directly to ceiling or over-head member, simply and easily. The swivel mounting allows you to readily adjust the direction of warm air flow for maximum comfort up to 180 degrees. ADVANTAGES USelf-contained UVersatile, flexible and high performance UEasy installation UMinimum maintenance ULong life UAttractive appearance L-4 OMEGALUX metal sheath finned tubular heating elements. The electric Heat Bank—OMEGALUX spiral metal sheath finned tubular heating elements. They are shock proof! Heat radiation fins are corrosion-resistant steel, furnace brazed to the tubular heating elements for good heat transfer. They don’t come loose! Wide spacing prevents clogging. Totally enclosed, continuous duty, fan motor. It’s a totally enclosed, continuous duty unit unit, with built-in automatic reset overload protection. Operates on same voltages as line power supply. There’s no need for a stepdown transformer or separate motor circuit. Combination fan guard and motor mount is attached to housing of heater with rubber vibration isolators. They prevent vibration; make for quieter operation. Dynamically balanced fan. Dynamically balanced for smooth, quiet running. Blade pitch is carefully selected so that the volume of air moved results in the optimum discharge air temperature. Built-in thermal overload protection. Thermal overload cutouts open the control circuit and cutoff power to the heating elements should over-heating occur. Cutouts are the automatic reset type. When temperature falls to normal, they reclose the control circuit and power is restored. Automatic protection makes for safety. Also, long life. L HEAVY DUTY WALL OR CEILING MOUNT HORIZONTAL UNIT HEATER LUH Series U 2.6 to 45 kW U 208, 240, 277, 480V 1 & 3 phase U 8,900 to 153,600 BTU/Hr U Meets UL, NEC & OSHA Requirements U No Venting Necessary U Built-in Power Controls CAUTION AND WARNING! Fire and electrical shock may result if products are used improperly or installed or used by non-qualified personnel. See inside back cover for additional warnings. MADE IN USA To Order (Specify Model Number) Electrical (60 Hz) kW Volts 2.6 2.0/2.6 2.6 4 4 3/4 3/4 4 4 5 5 3.75/5 3.75/5 5 5 7.5 7.5 5.6/7.5 5.6/7.5 7.5 7.5 9.7 9.7 7.5/10 7.5/10 10 12.5 9.3/12.5 12.5 15 11.25/15 15 14.5/19.4 20 25 22.5/30 30 26.25/35 35 28.5/38 45 208 208/240 277 208 208 208/240 208/240 277 480 208 208 208/240 208/240 277 480 208 208 208/240 208/240 277 480 208 208 208/240 208/240 480 208 208/240 480 208 208/240 480 208/240 480 480 208/240 480 208/240 480 208/240 480 Ckt & Phase Amps3 Volts Phase 1-1 1-1 1-1 1-1 1-32 1-1 1-32 1-1 1-3 1-1 1-32 1-1 1-32 1-1 1-3 1-12 1-3 1-12 1-3 1-3 1-3 1-12 1-3 1-12 1-3 1-3 1-3 1-3 1-3 1-3 1-3 1-3 1-3 1-3 1-3 2-3 2-3 2-3 2-3 2-3 2-3 Most Popular Models Highlighted Motor 13.1 11.41 9.6 19.8 11.71 17.21 10.2 14.6 5.1 24.6 14.5 21.4 12.6 18.3 6.3 36.5 21.3 31.71 18.51 27.7 9.9 47.1 27.4 42.11 24.51 12.9 35.2 30.6 15.9 42.1 36.61 19.0 48.01 25.0 31.0 74.01 37.1 86.01 43.1 93.3 55.1 208 240 277 208 208 240 240 277 480 208 208 240 240 277 480 208 208 240 240 277 480 208 208 240 240 480 208 240 480 208 240 480 240 480 480 240 480 240 480 240 480 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3 1 1 1 1 3 1 1 3 1 1 3 3 3 3 3 3 3 3 3 3 HP RPM CFM Air Delivery Ordering Temp Horz Mtg4 Rise Throw Height FPM (°F) (Ft) (Ft) Model Number 1/50 1/50 1/50 1/50 1/50 1/50 1/50 1/50 1/50 1/50 1/50 1/50 1/50 1/50 1/50 1/10 1/10 1/10 1/10 1/10 1/10 1/10 1/10 1/10 1/10 1/10 1/10 1/10 1/10 1/10 1/10 1/10 1/10 1/10 1/10 1/3 1/3 1/3 1/3 1/3 1/3 1000 1000 1000 1000 1000 1000 1000 1000 1000 1050 1050 1050 1050 1050 1050 1550 1550 1550 1550 1550 1550 1550 1550 1550 1550 1550 1550 1550 1550 1550 1550 1550 1550 1550 1550 1725 1725 1725 1725 1725 1725 310 310 310 310 310 310 310 310 310 420 420 420 420 420 420 670 670 670 670 670 670 750 750 750 750 750 750 750 750 750 750 750 1240 1240 1350 1555 1555 1555 1555 1555 1555 700 700 700 700 700 700 700 700 700 950 950 950 950 950 950 850 850 850 850 850 850 950 950 950 950 950 950 950 950 950 950 950 1160 1160 1260 1450 1450 1450 1450 1450 1450 27 27 27 42 42 42 42 42 42 42 42 42 42 42 42 40 40 40 40 40 40 47 47 47 47 47 55 55 55 61 61 61 53 53 60 64 64 71 71 84 94 12 12 12 12 12 12 12 12 12 18 18 18 18 18 18 20 20 20 20 20 20 27 27 27 27 27 27 27 27 27 27 27 31 31 31 46 46 45 45 44 42 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 9 9 9 9 9 9 9 9 10 10 10 11 11 12 13 13 14 14 15 17 LUH-02-81-34/208 LUH-02-21-34/208/240 LUH-02-71-35/277 LHU-04-81-34/208 LHU-04-83-34/208 LHU-04-21-34/208/240 LHU-04-23-34/208/240 LHU-04-71-35/277 LHU-04-43-32/480 LHU-05-81-34/208 LHU-05-83-34/208 LHU-05-21-34/208/240 LHU-05-23-34/208/240 LHU-05-71-35/277 LHU-05-43-32/480 LHU-07-81-34/208 LHU-07-83-34/208 LHU-07-21-34/208/240 LHU-07-23-34/208/240 LHU-07-71-35/277 LHU-07-43-32/480 LHU-10-81-34/208 LHU-10-83-34/208 LHU-10-21-34/208/240 LHU-10-23-34/208/240 LHU-10-43-32/480 LHU-12-83-34/208 LHU-12-23-34/208/240 LHU-12-43-32/480 LHU-15-83-34/208 LHU-15-23-34/208/240 LHU-15-43-32/480 LHU-20-23-34/208/240 LHU-20-43-32 LHU-25-43-32 LHU-30-23-34/208/240 LHU-30-43-32/480 LHU-35-23-34/208/240 LHU-35-43-32/480 LHU-40-23-34/208/240 LHU-45-43-32/480 Price Wt Lb. $456 456 456 479 586 479 586 479 715 519 632 519 632 519 734 739 739 739 739 739 827 775 775 775 775 872 957 957 957 1311 1311 1311 1660 1660 2011 2484 2484 2913 2913 3106 3398 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 73 73 73 106 106 106 106 106 106 Ordering Example: LHU-07-83-34/208 is a 7.5 kW, 208 Volt Heater, $739. 1. 208V amperage is 86% of 240V value. 3. Includes motor amps 2. Models can be wired for 1 or 3 phase. 4. Maximum mounting height for effective heat distribution. Minimum height is 7 feet. L-5 INSTALLATION ACCESSORIES AND THERMOSTAT KITS FOR LUH SERIES Mounting Configurations for LUH Series Ceiling Mounted V (1) 11/16" dia. swivel mounting hole Wall Mount with Wall Mounting Bracket W N U A Ceiling Mount with Threaded Rod F J I 6" min to wall K G R M Welded fasteners (4) for threaded rod (by others) mounting to overhead steel. P Q T H To Order (Specify Model Number) A Wall Line S 4-13/32" dia. Stop for mounting holes limiting for fastening to rotation. wall fasteners by customer Swivel bolt permits heater to be rotated to face desired direction. Four bolts are provided for field attachment of swivel bracket to welded fasteners on top of unit. Min. distance to Wall with ceiling mount E B Type DPST SPST *Use With LUH-02 thru LUH-05 (without contactor) LUH-02 thru LUH-25 (with contactor) Thermostat Kits (Field-Installed) for LUH Series Model No. LUH-TK-2 Price $71 LUH-TK-1 59 C 6" D Note: Heater must be mounted at least 7' above floor. * All LUH heaters have contactor except LUH-02, LUH-04 and LUH-05 (single phase). L Contactors are optional on these models. Temperature Range: 40°F to 90°F differential: 5°F. To Order (Specify Model Number) Mounting Brackets for LUH Series MOUNTING LIMITATION Hazardous atmosphere—Unit heaters should not be used in potentially explosive atmospheres. Corrosive atmosphere—The finish is not intended for direct salt spray exposure in marine applications or the highly corrosive atmospheres of greenhouses, swimming pools, chemical storage bins, etc. Mounting height— Do not install unit heaters above recommended maximum mounting height. Obstructions— must not block unit heater air inlet or discharge. Wall Mount Dimension —Inches (cm) Use With P Q R S T Model No. Price LUH-02 thru -05 39⁄16(9) 205⁄8(52) 63⁄4(17) 4(10)141⁄2(37) WUH-01 $41 3 1 5 LUH-07 thru -25 4 ⁄16(11)31(79) 9 ⁄2(24) 7(18)19 ⁄8(50) WUH-02 61 LUH-30 thru -45 7(18) 281⁄2 (72) 5(13) — 329⁄16(83)WUH-03 101 Use With LUH-02 thru -05 LUH-07 thru -25 LUH-30 thru -45 Dimensions—Inches (cm) Model No. A LUH-02 thru-05 16(41) LUH-07,10,12,15 2012⁄ (52) LUH-02 thru-05 24(61) LUH-02 thru-05 24(61) Ceiling Mount Dimension —Inches (cm) M U V 6 (15) 4(10) 41⁄4(11) 8 (20) 6(15) 71⁄4(18) 3 13 ⁄4 (35) 6(15) 71⁄4(18) Price $31 35 62 Welded B C D Fasteners E 1 7 13 ⁄8(33) 8 ⁄8(23) 111⁄4(29) 5⁄16-18 101⁄4(26) 171⁄4(44) 1112⁄ (29) 15(38) 5⁄16-18 101⁄4(26) 201⁄8(51) 1112⁄ (29) 173⁄4(45) 5⁄16-18 101⁄4(26) 201⁄8(51) 1714⁄ (44) 24(61) 5⁄16-18 101⁄4(26) L-6 Model No. WUH-04 WUH-05 WUH-06 F G H I J K 1 5 1 9 ⁄4(25) 5(13) 4 ⁄16(10)4 ⁄8(12) 4 ⁄2(11) 65⁄8(17) 93⁄4(25) 5(13) 41⁄16(10)45⁄8(12) 41⁄2(11) 85⁄8(22) 93⁄4(25) 5(13) 41⁄16(10)45⁄8(12) 41⁄2(11) 10(25) 93⁄4(25) 5(13) 41⁄16(10)45⁄8(12) 41⁄2(11) 10(25) 3