Transcript
lumenline™ 2
Specification Sheet
SURFACE - WALL MOUNT DIRECT/INDIRECT LIGHTING SINGLE UNITS CONTINUOUS RUNS SHAPES
Client
Project name
Order# Type
Qty
FEATURES AND BENEFITS
Physical : • • • • • • • • • • • • • • • •
Aluminum extruded housing, 2” wide Available in 1’, 2’, 3’, 4’, 5’, 6’, 7’ or 8’ sections Continuous runs available in 1’ increments Durable polyester powder coat finish Wide flood indirect lighting optics Wide flood, true asymmetric wallwash or narrow flood direct lighting optics Wallwash and narrow flood optics provided with white painted louvers Black painted or semi-specular louver finish optional Wide flood direct optic provided with frosted extruded acrylic lens High reflective matte white powder coated reflector Wall mounted Tool-less system for reflector assembly and control gear access Compatible with motion sensors Unlit joiners and corners available for custom configurations Dry location only IK05 rated
CERTIFICADO No.05884, 05885 RETILAP
Performance summary
Performance : • • • • • • •
IK05
Based on RO, all color temperatures,
Available in 2700K, 3000K, 3500K, 4000K or RGB color mixing for direct and indirect lighting CRI value: 80+ Binning within a 3 step MacAdam ellipse Lumen maintenance: 100,000 hrs [L70 @ 25° C] Lumen measurements comply with LM - 79 - 08 standard Resolution per foot or per fixture (configured with LumenID V3 software & DMX/RDM) Operating temperatures: -25° C to 50° C [-13F to 122F]
White painted louver for NF and WW optics. Optic
Electrical :
Delivered Lumens/ output [lm/ft] Watt [lm/W]
Direct wide flood
492
87
Direct narrow flood
398
73
Direct true asymmetric wallwash
391
71
Indirect wide flood*
522
93
Photometric performance is measured in compliance with IESNA LM-79-08. *Estimated. Consult website for latest ies files.
• • • •
Line voltage luminaire for 100 to 347V 6W/ft Regular Output version, direct or indirect lighting 12W/ft High Output version, direct or indirect lighting Dimming options for white light: 0-10 volt, DMX/RDM enabled, DALI, Lumentalk or Lutron® EcoSystem® Enabled • 6W/ft optional RGB source, DMX/RDM enabled • Quick connectors for continuous runs 11 " 16 [68mm]
Wide flood (100˚) Direct
Narrow flood (30˚ x 60˚)
True asymmetric wallwash
Wide flood (100˚) Indirect
2
TOP VIEW, WIDE FLOOD OPTIC SHOWN
5 " 16 [84mm] 3
12 1 " , 24 1 " , 36 1 " , 47 7 " , 59 3 " , 71 9 " , 83 3 " , 95 1 " 2 4 16 8 4 16 8 4 [317mm, 616mm, 916mm, 1216mm, 1518mm, 1818mm, 2119mm, 2419mm]
9 " 16 [115mm]
FRONT VIEW
4
SIDE VIEW
BOTTOM VIEW, WIDE FLOOD OPTIC SHOWN
1/15
© Copyright Lumenpulse 2016
2016.07.28
1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6
EM - R19
1.877.937.3003 P.514.937.3003 F. 514.937.6289
[email protected] www.lumenpulse.com
5-year limited warranty. Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.
Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modification shall be effective immediately.
lumenline™ 2
Specification Sheet
SURFACE - WALL MOUNT DIRECT/INDIRECT LIGHTING SINGLE UNITS CONTINUOUS RUNS SHAPES
PHOTOMETRIC INFORMATION - DIRECT LIGHTING OPTICS WFL - Wide flood (100°), all color temperatures
Bottom view, frosted lens
Delivered output, 4f fixture [lm]
Candlepower distribution 4ft, HO
White light 439
RGB
RO
HO
1969
3727
357
N/A
CRI Value: 80+
878 1317
1756
NF - Narrow flood (30°x 60°), all color temperatures Not available for RGB or lit joiners
Bottom View, narrow flood louver
Candlepower distribution 4ft, HO White louver
Delivered output, 4f fixture [lm] Semi-specular louver
Black louver
964
1014
802
1928
2028
1605
2891
3042
2407
3855
4056
RO
HO
White louver
1591
2957
Black louver
1042*
1894
Semi-specular
1829*
3325
CRI Value: 80+
0˚-180˚
3209
0˚-180˚
90˚-270˚
90˚-270˚
0˚-180˚
90˚-270˚
WW - True asymmetric wallwash, all color temperatures Not available for RGB or lit joiners
Bottom view, wallwash louver
Candlepower distribution, 4ft, HO White louver
4ft, HO Black louver
878
903
1755
1805
2633
2708
3510
3610
Delivered output, 4f fixture [lm] RO
HO
White louver
1564
2783
Black louver
1174*
2135
-
-
Semi-specular CRI Value: 80+
Notes: Estimated. Consult website for latest ies fi les.
*
2/15
© Copyright Lumenpulse 2016
2016.07.28
1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6
EM - R19
1.877.937.3003 P.514.937.3003 F. 514.937.6289
[email protected] www.lumenpulse.com
5-year limited warranty. Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.
Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modification shall be effective immediately.
lumenline™ 2
Specification Sheet
SURFACE - WALL MOUNT DIRECT/INDIRECT LIGHTING SINGLE UNITS CONTINUOUS RUNS SHAPES
PHOTOMETRIC INFORMATION - INDIRECT LIGHTING OPTICS WFL - Wide flood (100°), all color temperatures*
Top view, clear lens
Candlepower distribution 4ft, HO
Delivered output, 4f fixture [lm]
1618
White light RGB
1213
RO
HO
2025
3969
480
N/A
CRI Value: 80+ 809 404
Notes: Estimated. Consult website for latest ies fi les.
*
3/15
© Copyright Lumenpulse 2016
2016.07.28
1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6
EM - R19
1.877.937.3003 P.514.937.3003 F. 514.937.6289
[email protected] www.lumenpulse.com
5-year limited warranty. Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.
Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modification shall be effective immediately.
lumenline™ 2
Specification Sheet
SURFACE - WALL MOUNT DIRECT/INDIRECT LIGHTING SINGLE UNITS CONTINUOUS RUNS SHAPES
LOUVER INSTALLATION DETAIL
Narrow Flood Symmetrical louver design, no specific orientation required
BOTTOM VIEW
True Asymmetric Wallwash
WWB True asymmetric wallwash distribution towards back of the fixture
WWF True asymmetric wallwash distribution towards front of the fixture
Always position louver blades toward the wall
Standard feeding side (left hand side when facing the wall)
BOTTOM VIEW
4/15
© Copyright Lumenpulse 2016
2016.07.28
1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6
EM - R19
1.877.937.3003 P.514.937.3003 F. 514.937.6289
[email protected] www.lumenpulse.com
5-year limited warranty. Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.
Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modification shall be effective immediately.
lumenline™ 2
Specification Sheet
SURFACE - WALL MOUNT DIRECT/INDIRECT LIGHTING SINGLE UNITS CONTINUOUS RUNS SHAPES
WALL MOUNTING DETAILS 1 " 4 [6mm]
6" [152mm]
5 " 8 [17mm]
Power/data feed into fixture
BACK VIEW
6 3 " 16 [157mm] 5" [127mm]
RIGHT VIEW
Wall mounting detail for 1’ units N.B. Horizontal 2" x 4" jonction box required 5 15 " 16 [151mm]
1 " 4 [6mm]
1 1 " 2 [38mm]
11 7 " 8 [300mm]
3 16 " [5mm] BACK VIEW
Power/data feed into fixture
1 1 2 " [38mm]
Mounting holes pattern for Wall mounting plate 11" 2 [38mm]
BACK VIEW
11" 2 [38mm]
Wall mounting detail for 2’ units N.B. Horizontal 2" x 4" jonction box required 1 " 4 [6mm]
7 15 " 16 [202mm]
AA
FRONT VIEW
Power/data feed into fixture
Fixture’s wall mounting plates positioning horizontal tolerance Nominal Mounting bracket spacing Dimension AA fixture length
BACK VIEW
Wall mounting detail for 3’ to 8’ units N.B. Horizontal 2" x 4" jonction box required
3'
19 5/8'' [498mm]
4'
31 7/16'' [799mm]
5'
43 5/16'' [1100mm]
6'
55 1/8'' [1400mm]
7'
67'' [1702mm]
8'
78 13/16'' [2002mm]
WALL MOUNTING DETAIL (CONTINUOUS RUN)
BACK VIEW
15 7 " 8 [403m]
5/15
© Copyright Lumenpulse 2016
2016.07.28
1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6
EM - R19
8 3" 16 [209mm] Power/data feed
1.877.937.3003 P.514.937.3003 F. 514.937.6289
[email protected] www.lumenpulse.com
5-year limited warranty. Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.
Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modification shall be effective immediately.
lumenline™ 2
Specification Sheet LIT JOINER TYPE AND DIMENSIONS Refer to the SHAPE ordering page Not available for true asymmetric wallwash and narrow flood optics
SURFACE - WALL MOUNT DIRECT/INDIRECT LIGHTING SINGLE UNITS CONTINUOUS RUNS SHAPES
HCNR* Horizontal 90o Used to build “L” shapes (Equivalent of a 4’ fixture)
17" [432mm]
17" [432mm]
3 " 8 [365mm] 14
TOP VIEW
*Mounting brackets installed on joiner longer sides. Consult factory for mounting brackets installed on joiner shorter sides.
6/15
© Copyright Lumenpulse 2016
2016.07.28
1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6
EM - R19
1.877.937.3003 P.514.937.3003 F. 514.937.6289
[email protected] www.lumenpulse.com
5-year limited warranty. Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.
Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modification shall be effective immediately.
lumenline™ 2
Specification Sheet
SURFACE - WALL MOUNT DIRECT/INDIRECT LIGHTING SINGLE UNITS CONTINUOUS RUNS SHAPES
UNLIT JOINER TYPE AND DIMENSIONS Refer to the SHAPE ordering page
CNR Corner 90o
LNR Linear 180o
*Consult factory for shapes requiring the LNR joiner. TYPICAL DIMENSIONS AND MOUNTING POINT LOCATIONS BB AA
5 " 8 [17mm]
Nominal fixture length
Overall fixture length Dimension AA
Overall fixture length with brackets Dimension BB
1'
14 7/8'' [379mm]
15 1/2'' [394mm]
2'
26 5/8'' [677mm]
27 1/4'' [692mm]
3'
38 1/2'' [977mm]
39 1/8'' [994mm]
4'
50 5/16' [1279mm]
50 15/16' [1294mm]
TOP VIEW
5'
62 1/16'' [1578mm]
FIRST OR END OF RUN
61 11/16'' [1592mm]
6'
73 15/16'' [1879mm]
74 9/16'' [1894mm]
7'
85 13/16'' [2181mm]
86 7/16'' [2196mm]
8'
97 5/8'' [2481mm]
98 1/4'' [2496mm]
DD CC
5" 8 [17mm]
FF
TOP VIEW
MIDDLE OF RUN
Nominal Overall fixture length fixture with corners length Dimension CC 1'
17 5/16'' [440mm]
18 9/16'' [471mm]
2'
29 1/16'' [738mm]
30 5/16'' [770mm]
3'
40 7/8'' [1038mm]
42 1/8'' [1070mm]
4'
52 3/4' [1340mm]
54' [1372mm]
5'
64 1/2'' [1639mm]
65 3/4'' [1670mm]
6'
76 3/8'' [1940mm]
77 5/8'' [1972mm]
7'
88 1/4'' [2242mm]
89 1/2'' [2273mm]
8'
100 1/16'' [2542mm]
101 5/16'' [2573mm]
Nominal fixture length
7/15
© Copyright Lumenpulse 2016
2016.07.28
1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6
EM - R19
1.877.937.3003 P.514.937.3003 F. 514.937.6289
[email protected] www.lumenpulse.com
Overall length with brackets Dimension DD
Middle of run fixture length Dimension FF
1'
11 15/16'' [303mm]
2'
23 11/16'' [602mm]
3'
35 1/2'' [902mm]
4'
47 3/8'' [1202mm]
5'
59 1/8'' [1504mm]
6'
71'' [1804mm]
7'
82 7/8'' [2104mm]
8'
94 11/16'' [2405mm]
5-year limited warranty. Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.
Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modification shall be effective immediately.
lumenline™ 2
Specification Sheet
SURFACE - WALL MOUNT DIRECT/INDIRECT LIGHTING SINGLE UNITS CONTINUOUS RUNS SHAPES
ACCESSORIES Order separately
Control Systems: LTO2 Lumentouch is a wall mount DMX 512 controller keypad. LCU Lumencue is a USB / mini SD DMX 512 controller. LID LumenID is a diagnostic and addressing DMX 512 controller. It must be specifi ed on all DMX applications. Refer to LID specifi cation sheet for details. LTN Lumentone is a simple pre-programmed DMX 512 controller with a push button rotary dial and live feedback.
Control Boxes: CBX DMX/RDM control box. Up to six power and data outputs to fi xtures or fi xture runs. Ethernet enabled option. Refer to CBX specifi cation sheet for details.
8/15
© Copyright Lumenpulse 2016
2016.07.28
1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6
EM - R19
1.877.937.3003 P.514.937.3003 F. 514.937.6289
[email protected] www.lumenpulse.com
5-year limited warranty. Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.
Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modification shall be effective immediately.
lumenline™ 2
Specification Sheet
SURFACE - WALL MOUNT DIRECT/INDIRECT LIGHTING SINGLE UNITS CONTINUOUS RUNS SHAPES
RESOLUTION DETAILS Applicable for DMX/RDM control option only. Fixture resolution can be configured on-site within the LumenID V3 software. A DMX/RDM enabled CBX is required.
Resolution per foot: each foot is addressed independently Total number of DMX addresses required per fixture (Direct/Indirect)
Single units
Lit joiner
1ft
2ft
3ft
4ft
5ft
6ft
7ft
8ft
HCNR
WH/WH
2
4
6
8
10
12
14
16
6
WH/RGB
4
8
12
16
20
24
28
32
10
Resolution per fixture: each reflector is addressed independently Total number of DMX addresses required per fixture (Direct/Indirect)
Single units
Lit joiner
1ft to 4ft
5ft to 8ft
HCNR
WH/WH
2
4
2
WH/RGB
4
8
4
BOARD AND REFLECTOR LAYOUT PER FIXTURE LENGTH SINGLE UNITS
1 Reflector 1
2ft
3ft
4ft
5ft
6ft
7ft
8ft
4 1
Indirect Direct
Reflector 2
Reflector 1
6
Indirect Direct
3 2
Reflector 2 5
1
2 Reflector 1
8
7
1
2
8
Reflector 3 7
1
9
Reflector 2
Reflector 2 2
Reflector 2
Reflector 1
2 Reflector 1 Reflector 3 8
1
2 Reflector 1
11
10
1
2
12
11
1
2
Reflector 3
Reflector 1 Reflector 3
Reflector 1
HCNR Horizontal 90°
3
6
5
1
3
4
6
Reflector 4 9 10
3
5
7
10
3
6
5 Reflector 2
9
8
12
3
4
7
6 Reflector 2
10
9
13
14
3
4
8
7
Indirect Direct
© Copyright Lumenpulse 2016
2016.07.28
1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6
2
6
Reflector 3
4
Indirect Direct
Reflector 4 11
12
Reflector 2
9/15
EM - R19
Reflector 1
Direct
Indirect Direct
4
4
3
Reflector 4
1ft
LIT JOINER IN SHAPES
5
Indirect
4
Indirect Direct
Reflector 4 13
14
1.877.937.3003 P.514.937.3003 F. 514.937.6289
[email protected] www.lumenpulse.com
5
Reflector 4 15 Reflector 2
6
Indirect Direct
16 5
Indirect Direct
5-year limited warranty. Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.
Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modification shall be effective immediately.
lumenline™ 2
Specification Sheet
SURFACE - WALL MOUNT DIRECT/INDIRECT LIGHTING SINGLE UNITS CONTINUOUS RUNS SHAPES
RESOLUTION DETAILS - continued
Example: DMX addresses, resolution per foot, 8ft fixture and HCNR lit joiner 11 31, 32, 33
10 28, 29, 30
9 25, 26, 27
13 37, 38, 39
14 15 40, 41, 42 43, 44, 45
Reflector 3
Reflector 4
Reflector 1
Reflector 2
16 46, 47, 48
Indirect Direct
8ft
2 4, 5, 6
3 7, 8, 9
1 1, 2, 3
HCNR Horizontal 90°
2 4, 5, 6
4 10, 11, 12
Reflector 2
1 1, 2, 3
8 22, 23, 24
7 6 19, 20, 21 16, 17, 18
4 10, 11, 12 5 13, 14, 15 3 7, 8, 9
Reflector 1
White light version RGB version
5 13, 14, 15
Reflector 4
12 34, 35, 36
6 16, 17, 18
Reflector 3
Direct
Indirect
Example: DMX addresses, resolution per fixture, 8ft fixture and HCNR lit joiner 3 7, 8, 9
4 10, 11, 12
Reflector 3
Reflector 4
Reflector 1
Reflector 2
1 1, 2, 3
2 4, 5, 6
HCNR Horizontal 90°
Reflector 2
1 1, 2, 3
2 4, 5, 6
Reflector 1
Reflector 3
Direct
10/15
© Copyright Lumenpulse 2016
2016.07.28
1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6
EM - R19
Reflector 4
Indirect Direct
8ft
Indirect
1.877.937.3003 P.514.937.3003 F. 514.937.6289
[email protected] www.lumenpulse.com
5-year limited warranty. Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.
Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modification shall be effective immediately.
lumenline™ 2
Specification Sheet
SURFACE - WALL MOUNT DIRECT/INDIRECT LIGHTING SINGLE UNITS CONTINUOUS RUNS SHAPES
TYPICAL WIRING DIAGRAMS
Non-dimming or Lumentalk wiring detail
Non-dimming or Lumentalk control options Single units, daisy chain configuration
Junction box (by others)
Line black Ground green Neutral white
100-347V* Input
100-347V* To next fixture
To fixture
100-347V*
0-10V, DALI or EcoSystem® control options
0-10V, DALI or EcoSystem® wiring detail
Single units, daisy chain layout
100-347V* input Junction box (by others)
Data- orange Data+ red/ purple
Line black Ground green Neutral white 100-347V* & Data output To next fixture
From Dimmer or Controller
100-347V* Data input To fixture
1x EcoSystem® address per reflector. Total number of EcoSystem® addresses required per fixture:
1x DALI address per reflector. Total number of DALI addresses required per fixture: Single units WH/WH
Lit joiner
1ft to 4ft
5ft to 8ft
HCNR
2
4
2
Single units
Lit joiner
2ft to 4ft
5ft to 8ft
HCNR
2
4
2
WH/WH
DMX/RDM control option
DMX/RDM wiring detail
Single units, star layout
Data- orange Data+ red/ pruple
Junction box (by others)
Line black Ground green Neutral white
From CBX 100-347V* & Data input
100-347V* Data input
To fixture
CBX
100-347V* & Data For stable DMX/RDM data signal,do not split data wires after the CBX.
*Lumentalk and RGB options not available with 347V. Maximum run lengths - 7A maximum with 10ft [3m] fixture cord Configuration/Voltage RO/RO HO/RO
100V
120V
208V, 220V, 240V, 277V, 347V
47ft [14.3m] 56ft [17.1m] 32ft [9.8m]
36ft [11m]
63ft [19.2m] 63ft [19.2m]
Notes:
WIRE COLOR / USE GREEN WHITE BLACK RED/ PURPLE ORANGE
GROUND NEUTRAL LINE 100-347V DATA + DATA -
1 Maximum run length calculations are typically based on 4ft [1.2m]. Each lumenline reflector requires 1x DMX/RDM or DALI address: a lumenline fixture can contain multiple reflectors, refer to Board and Reflector Layout for details. Consult factory for specific applications.
11/15
© Copyright Lumenpulse 2016
2016.07.28
1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6
EM - R19
1.877.937.3003 P.514.937.3003 F. 514.937.6289
[email protected] www.lumenpulse.com
5-year limited warranty. Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.
Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modification shall be effective immediately.
lumenline™ 2
Specification Sheet
SURFACE - WALL MOUNT DIRECT/INDIRECT LIGHTING SINGLE UNITS CONTINUOUS RUNS SHAPES
TYPICAL WIRING DIAGRAMS
Non-dimming or Lumentalk wiring detail
Non-dimming or Lumentalk control options Continuous run, single feed
Junction box (by others)
Line black Ground green Neutral white
100-347V* Input
100-347V* To next fixture
Quick connectors To fixture
100-347V*
0-10V, DALI or EcoSystem® control options
0-10V, DALI or EcoSystem® wiring detail
Continuous run, single feed
100-347V* input Data- orange Data+ red/ purple
Junction box (by others)
Line black Ground green Neutral white 100-347V* & Data output To next fixture
From Dimmer or Controller
Quick connectors Data input
To fixture
100-347V*
1x EcoSystem® address per reflector. Total number of EcoSystem® addresses required per fixture:
1x DALI address per reflector. Total number of DALI addresses required per fixture: Single units WH/WH
Lit joiner
1ft to 4ft
5ft to 8ft
HCNR
2
4
2
Single units
Lit joiner
2ft to 4ft
5ft to 8ft
HCNR
2
4
2
WH/WH
*Lumentalk and RGB options not available with 347V.
Maximum run lengths - 7A maximum with 10ft [3m] fixture cord Configuration/Voltage RO/RO HO/RO
100V
120V
208V, 220V, 240V, 277V, 347V
47ft [14.3m] 56ft [17.1m] 32ft [9.8m]
36ft [11m]
63ft [19.2m] 63ft [19.2m]
Notes:
WIRE COLOR / USE GREEN WHITE BLACK RED/ PURPLE ORANGE
GROUND NEUTRAL LINE 100-347V DATA + DATA -
1 Maximum run length calculations are typically based on 4ft [1.2m]. Each lumenline reflector requires 1x DMX/RDM or DALI address: a lumenline fixture can contain multiple reflectors, refer to Board and Reflector Layout for details. Consult factory for specific applications.
12/15
© Copyright Lumenpulse 2016
2016.07.28
1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6
EM - R19
1.877.937.3003 P.514.937.3003 F. 514.937.6289
[email protected] www.lumenpulse.com
5-year limited warranty. Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.
Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modification shall be effective immediately.
lumenline™ 2
Specification Sheet
SURFACE - WALL MOUNT DIRECT/INDIRECT LIGHTING SINGLE UNITS CONTINUOUS RUNS SHAPES
TYPICAL WIRING DIAGRAMS - continued
DMX/RDM wiring detail
DMX/RDM control option Continuous run, single feed
Data- orange Data+ red/ pruple
Junction box (by others)
Line black Ground green Neutral white
From CBX 100-347V* & Data input
Quick connectors
100-347V* Data input
100--347V* & Data
To fixture
CBX
DMX/RDM control option Continuous run, multiple feeds
Circuit #1 100-347V*
100-347V* & Data
100-347V* & Data
Circuit #2 100-347V* CBX
Data input
Data
CBX
For stable DMX/RDM data signal, do not split data wires after the CBX.
*Lumentalk and RGB options not available with 347V.
Maximum run lengths - 7A maximum with 10ft [3m] fixture cord Configuration/Voltage RO/RO HO/RO
100V
120V
208V, 220V, 240V, 277V, 347V
47ft [14.3m] 56ft [17.1m] 32ft [9.8m]
36ft [11m]
63ft [19.2m] 63ft [19.2m]
Notes:
WIRE COLOR / USE GREEN WHITE BLACK RED/ PURPLE ORANGE
GROUND NEUTRAL LINE 100-347V DATA + DATA -
1 Maximum run length calculations are typically based on 4ft [1.2m]. Each lumenline reflector requires 1x DMX/RDM or DALI address: a lumenline fixture can contain multiple reflectors, refer to Board and Reflector Layout for details. Consult factory for specific applications.
13/15
© Copyright Lumenpulse 2016
2016.07.28
1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6
EM - R19
1.877.937.3003 P.514.937.3003 F. 514.937.6289
[email protected] www.lumenpulse.com
5-year limited warranty. Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.
Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modification shall be effective immediately.
lumenline™ 2
Specification Sheet
SURFACE - WALL MOUNT DIRECT/INDIRECT LIGHTING SINGLE UNITS CONTINUOUS RUNS
HOW TO ORDER - SINGLE UNITS AND CONTINUOUS RUNS LLI2S
WM
DI
1
2
3
Select:
Select:
4
Select:
Select:
5
6
1 Housing:
Select:
WFL 7
Select:
Select:
Select:
8
9
10
7 Indirect Lighting: Output & Color temperature:
LLI2S - Lumenline™ Surface 2" wide
iRO 27K - 2700K regular output 6W/ft iRO 30K - 3000K regular output 6W/ft iRO 35K - 3500K regular output 6W/ft iRO 40K - 4000K regular output 6W/ft iHO 27K - 2700K high output 12W/ft2 iHO 30K - 3000K high output 12W/ft2 iHO 35K - 3500K high output 12W/ft2 iHO 40K - 4000K high output 12W/ft2 iRO RGB - Tri-color red, green and blue direct lighting 6W/ft3
2 Mounting: WM - Wall Mount
3 Light Direction: DI - Direct/Indirect lighting
4 Voltage:
Optics:
100 - 100 volts 120 - 120 volts 208 - 208 volts 220 - 220 volts
240 - 240 volts 277 - 277 volts 347 - 347 volts1
5 Length: SU1 - Single Unit 12 1/2 inches (317mm) SU2 - Single Unit 24 1/4 inches (616mm) SU3 - Single Unit 36 1/16 inches (916mm) SU4 - Single Unit 47 7/8 inches (1216mm) SU5 - Single Unit 59 3/4 inches (1518mm) SU6 - Single Unit 71 9/16 inches (1818mm) SU7 - Single Unit 83 3/8 inches (2119mm) SU8 - Single Unit 95 1/4 inches (2419mm) C__ - Continuous run, specify in 1’ increments.
6 Direct Lighting:
WFL - Wide flood, 100° distribution, clear lens
8 Control: NO - On/Off control LT - Lumentalk5 DIM - 0-10V Dimming option6 DMX/RDM - DMX/RDM enabled7 DALI - DALI Dimming option8 ES - Lutron® EcoSystem® Enabled Dimming9
9 Finish: BK - Black Sandtex SI - Silver Sandtex WH - Smooth white CC - Custom color and finish (please specify RAL color)10
10 Option:
Output & Color temperature:
dRO 27K - 2700K regular output 6W/ft dRO 30K - 3000K regular output 6W/ft dRO 35K - 3500K regular output 6W/ft dRO 40K - 4000K regular output 6W/ft dHO 27K - 2700K high output 12W/ft2 dHO 30K - 3000K high output 12W/ft2 dHO 35K - 3500K high output 12W/ft2 dHO 40K - 4000K high output 12W/ft2 dRO RGB - Tri-color red, green and blue direct lighting 6W/ft3
BLL - Black painted louver11 SSL - Semi-specular louver11 Photometric performance will vary with black and semi-specular louver options, see Photometric Information pages for more information.
Optics:
WFL - Wide flood, 100° distribution, frosted lens NF - Narrow flood, 30° distribution, highly reflective white painted louver4 WWB - True asymmetric wallwash distribution towards back of the fixture, highly reflective white painted louver4 WWF - True asymmetric wallwash distribution towards front of the fixture, highly reflective white painted louver4
Notes: 1
347V is not available for 1' [305mm] lengths. 347V is not available for RGB color option or LT control option. 2 High output direct lighting cannot be combined with high output indirect lighting. 3 RGB
option requires DMX/RDM control to be specified in Control section. 4 Not available for RGB color option. 5 1% minimum dimming value. Available with white light only, not available for 1' lengths [305mm]. 6
10% minimum dimming value. 7 1% minimum dimming value. Fixtures set to by fixture resolution (consult the Resolution Details pages for the number of DMX addresses per fixture length and type).
8
1% minimum dimming value. Available with white light only. Consult Typical Wiring Diagram pages for the number of DALI addresses per fixture length and type. 9 1% minimum dimming value. Available with
white light only, not available for 1' [305mm] lengths. Consult Typical Wiring Diagram pages for the number of EcoSystem® addresses per fixture length and type. 10 North American RAL colors specified with RAL number only are provided with a smooth/high-gloss finish. Please consult factory for other RAL textures and glosses, or to match alternate color charts. Final color matching results may vary.
11
Available for WWB,
WWF and NF optics, not compatible with WFL option.
14/15
© Copyright Lumenpulse 2016
2016.07.28
1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6
EM - R19
1.877.937.3003 P.514.937.3003 F. 514.937.6289
[email protected] www.lumenpulse.com
5-year limited warranty. Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.
Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modification shall be effective immediately.
lumenline™ 2
Specification Sheet
SURFACE - WALL MOUNT DIRECT/INDIRECT LIGHTING SINGLE UNITS CONTINUOUS RUNS SHAPES
HOW TO ORDER - SHAPES LLI2S
WM
DI
Select:
1
2
3
4
Select:
L 5
Select:
6
1 Housing:
Select:
Select:
7
WFL 8
Select:
Select:
Select:
9
10
11
8 Indirect Lighting: Output & Color temperature:
LLI2S - Lumenline Surface 2" wide ™
iRO 27K - 2700K regular output 6W/ft iRO 30K - 3000K regular output 6W/ft iRO 35K - 3500K regular output 6W/ft iRO 40K - 4000K regular output 6W/ft iHO 27K - 2700K high output 12W/ft2 iHO 30K - 3000K high output 12W/ft2 iHO 35K - 3500K high output 12W/ft2 iHO 40K - 4000K high output 12W/ft2 iRO RGB - Tri-color red, green and blue direct lighting 6W/ft3
2 Mounting: WM - Wall Mount
3 Light Direction: DI - Direct/Indirect lighting
4 Voltage:
Optics:
100 - 100 volts 120 - 120 volts 208 - 208 volts 220 - 220 volts
240 - 240 volts 277 - 277 volts 347 - 347 volts1
5 Length: IMPORTANT: Side length up to 20’ as a standard. Consult factory for any other shape requirements. L__ - ”L” shape: specify side length (equal segments)
WFL - Wide flood, 100° distribution, clear lens
9 Control: NO - On/Off control LT - Lumentalk5 DIM - 0-10V Dimming option6 DMX/RDM - DMX/RDM enabled7 DALI - DALI Dimming option8 ES - Lutron® EcoSystem® Enabled Dimming9
10 Finish:
6 Joiner Type: LJ - Lit joiner, 17 inches nominal side length module UJ - Unlit joiner, 2 11/16 inches (68mm) module (0.77kg/1.7 lbs)
7 Direct Lighting:
BK - Black Sandtex SI - Silver Sandtex WH - Smooth white CC - Custom color and finish (please specify RAL color)10
11 Option:
Output & Color temperature:
dRO 27K - 2700K regular output 6W/ft dRO 30K - 3000K regular output 6W/ft dRO 35K - 3500K regular output 6W/ft dRO 40K - 4000K regular output 6W/ft dHO 27K - 2700K high output 12W/ft2 dHO 30K - 3000K high output 12W/ft2 dHO 35K - 3500K high output 12W/ft2 dHO 40K - 4000K high output 12W/ft2 dRO RGB - Tri-color red, green and blue direct lighting 6W/ft3
BLL - Black painted louver11 SSL - Semi-specular louver11 Photometric performance will vary with black and semi-specular louver options, see Photometric Information pages for more information.
Optics:
NF, WWB and WWF optics not available for shapes with lit joiner. WFL - Wide flood, 100° distribution, frosted lens NF - Narrow flood, 30° distribution, highly reflective white painted louver4 WWB - True asymmetric wallwash distribution towards back of the fixture, highly reflective white painted louver4 WWF - True asymmetric wallwash distribution towards front of the fixture, highly reflective white painted louver4
Notes: 1
347V is not available for 1' [305mm] lengths. 347V is not available for RGB color option or LT control option. 2 High output direct lighting cannot be combined with high output indirect lighting. 3 RGB
option requires DMX/RDM control to be specified in Control section. 4 Not available for RGB color option and lit joiners. 5 1% minimum dimming value. Available with white light only, not available for 1' [305mm] lengths. 5 10% minimum dimming value. 7 1% minimum dimming value. Fixtures set to by fixture resolution (consult the Resolution Details pages for the number of DMX addresses per fixture length and type). 8 1% minimum dimming value. Available with white light only. Consult Typical Wiring Diagram pages for the number of DALI addresses per fixture length and type. 9 1% minimum dimming value. Available with white light only, not available for 1' [305mm] lengths. Consult Typical Wiring Diagram pages for the number of EcoSystem® addresses per fixture length and type. 10 North American RAL colors specified with RAL number only are provided with a smooth/high-gloss finish. Please consult factory for other RAL textures and glosses, or to match alternate color charts. Final color matching results may vary. 11
Available for WWB, WWF and NF optics, not compatible with WFL option.
15/15
© Copyright Lumenpulse 2016
2016.07.28
1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6
EM - R19
1.877.937.3003 P.514.937.3003 F. 514.937.6289
[email protected] www.lumenpulse.com
5-year limited warranty. Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.
Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modification shall be effective immediately.