Preview only show first 10 pages with watermark. For full document please download

Lvld3, Lvld2, Lvld1, Lvrd1, Lvgd1, Lvgd3, Lvgd2, Lvrd3, Lvrd2, Lvsd3, Lvsd2, Lvsd1

   EMBED


Share

Transcript

CAP-DCA Electronic Faucet Specifications • Capacitive-Sensing Omnidirectional Detection Zone • 0.5 GPM (1.9 L/Min) Outlet Flow Rate standard • Optional 0.35 GPM (1.3 L/Min) available upon request • Battery Operation; Uses Four "AA" Cell Batteries (included) • CSA Certified / IAPMO Listed • ADA Compliant; Meets ASME A117.1 (requires less than 5 lbs. of operating force) • Complies With ASME A112.18.1 • Verified compliant with .25% weighted average Pb content regulations Deck-mounted electronic lavatory faucet with battery operation has cast chromeplated brass spout, surface-mount control box and capacitive-sensing omnidirectional detection zone. Faucet features hands free (touchless) operation with integral spout sensor (no visible sensor). Auto shut-off feature is factory-set to 45 seconds. Will reset and recalibrate once obstruction is removed. Adjustable sensing distance 0 to 3.5" (0 to 88.9mm), factory set to 3.5" (89mm) ± 1⁄8". Low battery audible beep will activate after faucet shuts off when approximately 1500 cycles remain. Requires thermostatic mixing valve (available from Bradley) and four "AA" cell batteries (included). Optional Plug-In Transformer (PT): AC option power for faucets with battery operation. Plug-in connection. Input voltage 120 VAC @ 60 Hz. Output voltage (unloaded) 24 VAC ± 5% @ 19.2 VA. Current draw 800 MA. Operating temperature range 14° F to 104° F (-10° C to 40° C). Screw-type #6 universal pan-head terminals. UL listed and CSA certified. For optimum performance of this product, a system pressure between 20 and 80 PSI static is reccommended. This product will operate up to a maximum of 125 PSI static per ANSI and CSA requirements. However, pressures above 80 PSI are not recommended. Thermal expansion or leaking pressure reducing Adapter (included with Optional PT): Input voltage 24 VAC @ 60 Hz. Output valves may require use of expansion tanks or relief valves to ensure your voltage 6.4 VDC ± 5%. Current draw 600 MA. Operating temperature range X° F to X° F (-55° C to 85° C). Connections #22 AWG stripped wire (to plug-in transformer) and system never exceeds its maximum intended pressure setting. 9 VDC snap (to faucet battery pack). Wire length is 18". UL listed and CSA certified. Operation Faucet features hands free (touchless) operation. Water flows when sensor is activated and stops upon deactivation of the sensor. 5.95" (151mm) 1.81" (46mm) .40" (10mm) 4.07" (103mm) 5° 4.91" (125mm) 1.50" (38mm) max. deck thickness Ø 1.25" (32mm) 2.55" (65mm) 20.87" (530mm) Braided polymer waterline Inlet ⁄8" compression connection 3 Verify all rough-in dimensions prior to installation. Consult local and national codes. Conformity and compliance to local and national codes is the responsibility of the installer. Page 1 of 2 2/3/2014 This information is subject to change without notice. Bradley_Faucet_CAP-DCA 4.44" (113mm) .90" (23mm) 1.80" (46mm) © 2015 Bradley P.O. Box 309, Menomonee Falls, WI 53052-0309 800 BRADLEY (800 272 3539) +1 262 251 6000 bradleycorp.com CAP-DCA Electronic Faucet Surface-Mount Housing (external side view) Surface-Mount Housing (external front view) 5.46" (139mm) 15.00" (381mm) max. to top of deck 1.42" (36mm) 5.70" (145mm) 6.16" (156mm) 3.96" (101mm) 4.14" (105mm) 1.49" (38mm) ⁄8" Allen screw 1 3.33" (84mm) Optional Plug-In Transformer (PT) 2.48" (63mm) 2.14" (54mm) Surface-Mount Housing (internal front view) Controller 3.62" (92mm) ⁄8" compression connection outlet 3 Solenoid Valve 1" (25mm) Battery Holder .36" (9mm) 28" (711mm) sensing wire Verify all rough-in dimensions prior to installation. Consult local and national codes. Conformity and compliance to local and national codes is the responsibility of the installer. Page 2 of 2 2/3/2014 This information is subject to change without notice. Bradley_Faucet_CAP-DCA Inlet 3⁄8" NPT or 3 ⁄8" compression adapter (supplied) 1.50" (38mm) Adapter included with optional PT. © 2015 Bradley P.O. Box 309, Menomonee Falls, WI 53052-0309 800 BRADLEY (800 272 3539) +1 262 251 6000 bradleycorp.com