Preview only show first 10 pages with watermark. For full document please download

Lx-pr-105 说明书(1)

   EMBED


Share

Transcript

LX-PR105 Infrared Sensor Instruction 71.00mm 62.00mm 62.00mm 25.50mm Summary The product is a new saving-energy switch adopting the good sensitivity detector, integrated circuit and SMT. It gathers automatic, convenient, safe, saving-energy and practical functions. The wide detection field is made up of up and down, left and right service field. It works by receiving human motion infrared rays. When one enters the detection fields, it can start the load at once and identify day and night automatically;It can be used with various types of lamps and lanterns . Specifications Light-control: <10LUX~2000LUX (adjustable) Time setting: min:8±3sec max:8±3Min Detection range: 8m max(<22°C) Detection angle: 360° Installation height: 2.5m~3.5m Working temperature: -10~+40°C Detection motion speed: 0.6~1.5m/s Working humidity:<93%RH Power consumption:0.45W(static 0.1W) Power source: 220-240V/AC 100-130V/AC Power frequency: 50/60Hz Rated load: 800W Max.tungsten(220-240V/AC) 200W Max.fluorescent(220-240V/AC) 400W Max.tungsten(100-130V/AC) 100W Max.fluorescent(100-130V/AC) Sensor information 360º Max:8m 2.5~3.5m Max:8m Height of installation:2.5~3.5m (Height of installation2.5~3.5M) Sensing distance adjustment range Sensing angle adjustment range Function  Detection field: the detection field is made up of up and down, left and right service field, it can be selected according to the consumer’s desire. But the moving orientation has great relationship with the sensitivity.  Can identify day and night: the light control can be adjusted freely when it works. It can work in the daytime  and at night when it is adjusted on the “sun” position (max); but it can only work in the light control less than 10lux when it is adjusted on the “moon” position (min). As for the adjustment pattern, please refer to the testing pattern. Time setting can be added continually: when it received the second induction signal after the first .it will compute time once more on the rest of the first time delay basic.(Set time)  Light-control potentiometer (LUX): clockwise the knob to increase its value; anti-clockwise the knob to decrease its value.  Time potentiometer (TIME): clockwise the knob to increase its value, the maximum delay time is 8±3 minutes; anti-clockwise the knob to decrease its value, the minimum delay time is 8±3 seconds.  Sensitivity potentiometer (SENS): clockwise the knob to increase its value, the maximum distance is 10±2m; anti- clockwise the knob to decrease its value, the minimum distance is 3±2m. Installation (see the following diagram)  Switch off the power.  Set threaded tubes into the power cord and control line.  Connect the power and the load with the sensor according to the connection-wire diagram. N Brown N Blue Load 1 1.0 0mm Sensor L' 21 .0 0mm L 36.50mm Test Turn the light-control knob clockwise on the maximum(sun), turn the time knob anti-clockwise on the minimum,turn the sensitivity knob clockwise on the maximum. 1.When connected to the electricity for 30 seconds, the sensor is in its working state. After the light goes out, shake your hand in right ahead of the sensor’s detecting window, the light should go on after the sensor detects the signal. Without continuous detecting for 8±3s, the light should go out. 2.Anti- clockwise the light-control knob to its minimum value ( night), after the light goes out, shake your hand in right ahead of the sensor’s detecting window, the light are off. Cover the detecting window with non-transparent objects (black cloth), the light will go on when detecting one time, Without continuous detecting for 8±3s, the light should go out. First, clockwise the light-control knob to its maximum value (daytime). Then clockwise the time and sensibility knob to its maximum value. Counting the time when connected to the electricity, the light should go out in 8±3min. 3.When connected to the electricity for 30 seconds, the sensor is in its working state. Start detecting after the light goes out. The light will go on when the sensor detects the signal. Stop detecting; the light will go out in 8±3s in case that the sensor detects no signal. Anti-clockwise the light-control knob to its minimum value (night), starts detecting after the light goes out, the light are off. Decrease the brightness of the darkroom slowly; the light will go on when the lumen is less than 10 LUX. Stop detecting; the light will go out in 8±3s. + TIME + SENS LUX Notes      Electrician or experienced human can install it. The unrest objects can’t be regarded the installation basis-face. In front of the detection window there should be no hinder or unrest objects effecting detection. Avoid installing it near air temperature alteration zones for example: air condition, central heating, etc. Please don’t open the case for your safety if you find the hitch after installation. Some problem and solved way  The load don’t work: a: Check the power and the load. b: If the load is good. c: Please check if the working light correspond to the light-control.  The sensitivity is poor: a: Please check if in front of the detection window there is hinder that effect to receive the signals. b: Please check if the ambient temperature is too high. c: Please check if the signals source is in the detection fields. d: If the moving orientation is right.  The sensor can’t shut automatically the load: a: If there is continual signal in the detection fields. b: If the time setting is set to the longest. c: If the power correspond to the instruction. d: If the air temperature change near the sensor, for example air condition or central heating etc.