Power analyzers M-CVM-AB Expansion modules M-CVM-AB-8I-8OTR Description Expansion module with 8 digital inputs and 8 transistor outputs. Applications Digital inputs Reports via communications: ——Logic states of non-unit external systems ——Metering of the impulses generated by other units (water and gas meters, etc.) Digital outputs ——Activation / deactivation by maximum or minimum instantaneous parameter values measured by the unit ——Generation of impulses by incremental parameters measured by the unit Technical features Maximum power consumed 3W Mechanical Terminal protection IP 20 Logical inputs Type of input Voltage-free / NPN Type of coupling Optoisolated input Maximum voltage 12 Vdc ION 4 mA Input consumption < 0.25 W Minimum times tON 40 ms tOFF 40 ms Static outputs Digital outputs Code Number of inputs 8 Connection 0.05-1.5 (AWG 30-14) mm2 Terminal tightening torque 0.3 Nm Rated voltage 250/150 Vac / Vdc Nominal current < 100 mA Maximum current < 150 mA Maximum dissipation power 0.5 W Maximum R ON 80 No. of outputs 8 Connection 0.05-2.5 (AWG 30-12) mm2 Terminal tightening torque 0.6 Nm M56E01 17 Power analyzers Expansion modules M-CVM-AB-8I-8OTR M-CVM-AB Connections 1 2 3 4 5 6 7 8 9 10 Terminals on the upper face List of terminals on the upper face, transistor digital inputs/outputs module Unit terminals Terminals of transistor digital inputs/ outputs, upper face 11 12 13 14 15 16 17 18 19 1 T1 Digital output of transistor 1 6 T5 Digital output of transistor 5 2 T2 Digital output of transistor 2 7 T6 Digital output of transistor 6 3 T3 Digital output of transistor 3 8 T7 Digital output of transistor 7 4 T4 Digital output of transistor 4 9 T8 Digital output of transistor 8 5 CT Shared by the transistor's digital outputs 10 CT Shared by the transistor's digital outputs Terminals on the lower face List of terminals on the lower face, transistor digital inputs/outputs module Unit terminals Terminals of transistor digital inputs/ outputs, lower face 11 GND For digital inputs: 16 I5 Digital input 5 12 I1 Digital input 1 17 I6 Digital input 6 13 I2 Digital input 2 18 I7 Digital Input 7 14 I3 Digital input 3 19 I8 Digital input 8 15 I4 Digital input 4 Transistor digital outputs Digital inputs 12 V DC Optoacoplador 10k 10k 1 2 3 4 5 6 7 8 9 10 COMM 11 3k 3k NPN Tensión Externa Connection diagram, transistor digital outputs 18 Connection diagram, digital inputs 19 Libre potencial Power analyzers M-CVM-AB Expansion modules M-CVM-AB-8I-8OR Description Expansion module with 8 digital inputs and 8 relay outputs. Applications Digital inputs ——Reports via communications: ——Logic states of non-unit external systems ——Metering of the impulses generated by other units (water and gas meters, etc.) Digital outputs ——Activation / deactivation by maximum or minimum instantaneous parameter values measured by the unit Technical features Maximum power consumed 3W Mechanical Terminal protection IP 20 Logical inputs Type of input Voltage-free / NPN Type of coupling Optoisolated input Maximum voltage 12 Vdc I ON 4 mA Input consumption < 0.25 W Minimum times tON 40 ms tOFF 40 ms Relay outputs Number of inputs 8 Connection 0.05-1.5 (AWG 30-14) mm2 Terminal tightening torque 0.3 Nm Rated voltage 12 V Nominal current 10 mA Maximum load Vac 250/5 Vac / A Maximum load Vdc 30/5 Vdc / A Minimum relay load 100 mV dc 100 μA Digital outputs Code Mechanical working life 2 x 107 cycles Electrical working life at rated load 5 x 104 cycles Number of outputs 8 Connection 0.05-2.5 (AWG 30-12) mm2 Terminal tightening torque 0.6 Nm M56E02 19 Power analyzers Expansion modules M-CVM-AB-8I-8OR M-CVM-AB Connections 1 2 3 4 5 6 7 8 9 10 Terminals on the upper face List of terminals on the upper face, relay digital inputs/outputs module Unit terminals Terminals of relay digital inputs/outputs, upper face 11 12 13 14 15 16 17 18 19 1 R1 Relay digital output 1 6 R5 Relay digital output 5 2 R2 Relay digital output 2 7 R6 Relay digital output 6 3 R3 Relay digital output 3 8 R7 Relay digital output 7 4 R4 Relay digital output 4 9 R8 Relay digital output 8 5 Rc Shared by all relay digital outputs 10 Rc Shared by all relay digital outputs Terminals on the lower face List of terminals on the lower face, relay digital inputs/outputs module Unit terminals Terminals of relay digital inputs/outputs, lower face Transistor digital outputs 11 GND For digital inputs: 16 I5 Digital input 5 12 I1 Digital input 1 17 I6 Digital input 6 13 I2 Digital input 2 18 I7 Digital Input 7 14 I3 Digital input 3 19 I8 Digital input 8 15 I4 Digital input 4 Digital inputs 12 V DC Relé 10k 10k 1 2 3 4 5 6 7 8 9 10 COMM 11 3k NPN 3k 19 Libre potencial Tensión externa Connection diagram, relay digital outputs 20 Connection diagram, digital inputs Power analyzers M-CVM-AB Expansion modules M-CVM-AB-4AI-8AO Description Expansion module with 4 analogue inputs and 8 analogue outputs. Applications Analogue inputs ——Measuring signal parameters for non-unit external processes. ——Viewing the signals on screen and reporting them via communications Analogue outputs ——Generating process signals for the instantaneous electrical parameters measured by the unit Technical features Maximum power consumed 3W Mechanical Terminal protection IP 20 Analogue inputs Type of measurement Current Nominal input range 0-20 / 4-20 mA dc Metering accuracy < 1% Input impedance 150 Ω Maximum acceptable input current 22 mA dc Number of inputs 4 Connection 0.05-1.5 (AWG 30-14) mm2 Terminal tightening torque 0.25 Nm Maximum internal voltage 12 V Nominal output range 0-20 / 4-20 mA Linearity <1% Maximum load resistor 300 Ω DAC resolution 4096 dots No. of configurable outputs in current mode 8 Maximum internal voltage 12 V Nominal output range 0-10 V Linearity <1% Minimum load resistor 5000 Ω DAC resolution 4096 dots No. of configurable outputs in current mode 8 Analogue outputs in current mode Analogue outputs in voltage mode Code M56E03 21 Power analyzers Expansion modules M-CVM-AB-4AI-8AO M-CVM-AB Connections 1 2 3 4 5 6 7 8 Terminals on the upper face 9 List of terminals on the upper face, analogue inputs/outputs module Unit terminals Analogue input/output terminals, upper face 1 O1 Analogue output 1 6 O5 Analogue output 6 2 O2 Analogue output 2 7 O6 Analogue output 7 3 O3 Analogue output 3 8 O7 Analogue output 8 4 O4 Analogue output 4 9 COM Shared by the analogue outputs 5 Oc Analogue output 5 Terminals on the lower face 10 11 12 13 14 15 16 17 List of terminals on the upper face, analogue inputs/outputs module Unit terminals 10 I1+ Analogue input 1 14 I3+ Analogue input 3 11 I1- Analogue input 1 15 I3- Analogue input 3 12 I2+ Analogue input 2 16 I4+ Analogue input 4 13 I2- Analogue input 2 17 I4- Analogue input 4 Analogue input/output terminals, lower face Analogue outputs D A Analogue inputs D D A 1 9 Connection diagram, analogue outputs 22 A 10 + Carga externa D A 17 Sensor 0/4 ...20 mA Connection diagram, analogue inputs + Sensor 0/4 ...20 mA Power analyzers M-CVM-AB Expansion modules M-CVM-AB-Modbus TCP-bridge Description Expansion module with Modbus/TCP communications (Ethernet). Applications Enables communications with SCADA systems, or similar, over TCP/IP computer networks using the Modbus/TCP protocol. Technical features Maximum power consumed 3W Mechanical Connections RJ-45 connector Protocol Ethernet Communications Bridge TCP to RS-485, Modbus TCP to Modbus/RTU Code M56E05 Connections C B(-) A(+) PC RS-485 Ethernet M-CVM-AB Expansion modules M-CVM-AB-Modbus TCP-switch Description Expansion module with Modbus/TCP communications (Ethernet). Applications It allows the Modbus TCP communication with SCADA systems in addition to Ethernet connectivity with other devices in cascade, avoiding long distances Ethernet cabling from centralized router or switch. Technical features Maximum power consumed 3W Mechanical Connections RJ-45 connector Protocol Ethernet Communications Bridge TCP to RS-485, Modbus TCP to Modbus/RTU Code M56E0A Connections C B(-) A(+) PC Ethernet M-CVM-AB-Modbus TCP-switch RS-485 M-CVM-AB-Modbus TCP-bridge M-CVM-AB-Modbus TCP-bridge 23 Power analyzers M-CVM-AB Expansion modules M-CVM-AB-MBus Description Expansion module with MBUS communications. Applications Enables the integration of units in MBUS communications networks (METER BUS). Technical features Maximum power consumed 3W Mechanical Input connection A+ / B- Output connection A+ / B- Bus Wired M-Bus M-Bus regulations EN 13757-2:2004, EN 13757-3:2004, EN 1434-3:2008 Protocol Slave M-BUS Baud Rate 300, 600, 1200, 2400, 4800, 9600 (configurable from the unit menu) Stop bits 1 Parity even Primary address 1 to 250 (configurable from the unit menu) Features Code M-CVM-AB M56E07 Expansion modules M-CVM-AB-LonWorks Description Expansion module with LonWorks communications. Applications Enables communication with SCADA systems, or similar, through the LonWorks protocol. Technical features Maximum power consumed 1,2 W Mechanical Connections RJ-45 connector Protocol LonWorks Communications Lon Talk ISO/IEC 14908 ANSI/EIA 7091 Code M56E08 Connections Red LonWorks AB 24 AB A B A B Power analyzers M-CVM-AB Expansion modules M-CVM-AB-Profibus Description Expansion module with Profibus communications. Applications Enables communication with SCADA systems, or similar, through the Profibus/DP protocol. Technical features Maximum power consumed 2W Mechanical Connections DB-9 Communications Profibus/DP Code M56E09 Master Profibus Connections Red Profibus / Network Profibus 25 Power analyzers M-CVM-B Expansion modules M-CVM-AB-Datalogger Description Expansion module for CVM-B that enables historical records. The data base is accessible using a WEB browser supporting HTML5 or PowerStudio Client (JAVA). Applications ——Data storage on the CVM-B itself ——200MB ring buffer. Up to 1 year averaged data every 15 minutes (average, maximum and minimum value in each record) ——Integrations with other SCADA systems through XML requests (Service integrated in the module ) ——Automatic synchronization with the PowerStudio data base in all versions ——Module Configuration throught the Editor of PowerStudio (free tool software) ——All the benefits of embedded PowerStudio. (Programming calculations, time discrimincación, events, user access profiles, etc.) ——Integrated HTML5 Web Server, visible using Smarthphones, tablets and PC directly ——E-mails sending from the own equipment, reporting any variable measured or calculated in the CVM-B. Technical features Maximum power consumed 3W Mechanical Terminal protection IP 30 Communications Connections RJ-45 Protocol Ethernet Communications Speed (Baudrate) Modbus / TCP Data storage Internal memory 200 MB Cyclic memory Code M56E06 Ethernet 10BT / 100BT Connections Con navegador Web compatible con Java With a browser compatible with Java Servidor PowerStudio (Opcional) Con navegador Web compatible con Java PowerStudio Server (Optional) With a browser compatible with Java Internet router Ethernet CVM-B M-CVM-AB-Datalogger Server / Servidor Web Server / Servidor XML PowerStudio DDBB 26