Preview only show first 10 pages with watermark. For full document please download

M201 - Mechanical Ductwork Plan Terrace Level

   EMBED


Share

Transcript

14.1 15.2 10.5 SEE DRAWING M206 FOR ENLARGED MECHANICAL ROOM AUDIO LAB 108 106 102 ANIMATION104 LAB T08 SEE DRAWING M206 FOR ENLARGED MECHANICAL ROOM 22"x18" T04 SD-10 ELEC. ROOM AL SD-12 2 130 CFM 18 FD 1 FD 68"x36" RG-1 10"x10" FD SEE DRAWING M207 FOR ENLARGED MECHANICAL ROOM MECHANICAL ROOM 12 28"x20" 16"x16" 255 CFM RG-1 5 T11 T ATC SD-32 22"x12" 12"ø EF-5 RG-1 30"x20" UP T14 B 32 12"ø 140 CFM (TYP 2) SD-13 SD-13 210 CFM E MEN'S RESTROOM T47 GENERAL LIBRARY STORAGE VAV WOMEN'S 3 RESTROOM 280 CFM ER-1 BUILDING STORAGE ROOM T41 RG-1 T45 70 CFM SD-6 RG-1 115 CFM JAN CLOSET LC MEDIA PREVIEW T46 T44 SD-6 LC MEDIA 115 CFM PREVIEW RG-1 SD-6 SD-6 105 CFM 105 CFM VAV 6 8"x8" SD-6 SD-6 50 CFM 50 CFM RG-1 T43 BROADCAST ASSISTANT T40 EEE SD-7 SD-7 170 CFM RG-1 SD-6 260 CFM RG-1 RG-1 45 CFM RG-1 RG-1 SD-31 SD-7 460 CFM (TYP. 4) RG-1 30"x22" SD-10 SD-30 RG-31 1000 CFM (TYP. 4) (TYP. 4) RG-1 240 CFM (TYP. 4) RG-1 165 CFM D.1 D.9 RG-1 120 CFM C.9 18" 260 CFM 160 CFM 165 CFM SD-34 SD-7 50 CFM 260 CFM 22"x18" 10"x8" 12"x10" SD-32 VAV 8 16"x12" SD-6 RG-1 DDD VAV 7 SD-32 SD-14 28" 8"ø 8"x8" VAV 4 SD-32 13.6 16 18" RG-1 10"x10" 8"x8" VAV 10 15.5 28" 8"x8" VAV 9 RG-1 18" 14"x10" 6"ø BROADCAST DIRECTOR 10"x8" 140 CFM 10"x8" ER-2 VAV 2 8"x8" 18"x12" 8"x8" 8"x6" 12"x8" ER-2 VAV 1 14"x10" 10"x10" 8"x8" T52 EF-11 13.4 10"ø 785 CFM 8 11 T 175 CFM 14"x14" 24"x16" 28"x18" T20 SD-7 EL2 TG-1 RG-1 18" CORRIDOR RG-1 8" ø 8"x8" 34"x18" ELEV #2 12"x12" 150 CFM 8"x8" 100 CFM T51 SD-7 175 CFM 16"x16" VAV 11 VAV 5 8"x8" 150 CFM 10"x8" SD-14 18"x12" 14"x8" 6"x6" RG-1 T48 EF-6 SD-7 10"x8" 10"x6" 95 CFM 8"x8" FD T53 VAV 12 CUSTODIAL T T01 155 CFM (TYP 2) 8"x8" CORRDIOR D 10 12 LOBBY SD-33 6"x6" RG-1 RG-1 SD-14 12"x8" 10"x8" T49EF-6 SD-7 10"x10" ELEV MACH ROOM 11 145 CFM RG-1 T62 RG-1 (TYP 2) RG-1 FD EF 11 ELEV LOBBY 12"x12" 26"x14" AS/RS VAULT SD-8 UP 70 CFM EL1 UP RG-1 18"x16" SD-14 9 1 18"x18" T02 14"x14" T61 ELEV #1 T60 ST1 75 CFM 140 CFM (TYP. 2) AL 2 8"x8" RG-1 ELEV LOBBY 8"ø ELEV LOBBY 145 CFM (TYP 6) NEWS SD-14 14"x12" 22"x12" FCU 1 135 CFM (TYP. 4) SD-6 28"x8" UP SD-16 RG-1 SD-16 FCU 2 14"x14" DHU 1 10"x6" (TYP 6) 140 CFM (TYP 2) VAV 13 28" RG-1 8"x8" 18 ATC 90 CFM RG-1 8"x8" RG-1 8"x8" RG-1 8"x8" 8"x8" 12"x10" ELEV MACH11 ROOM EF 255 CFM (TYP 3) RG-1 A.4 9 SD-32 VAV 14 10 SD-14 MECHANICAL ROOM 30"x16" T65 C T12 T13 TEL / DATA STAIR #1 CAFE STORAGE 24"x20" 14"x12" B.6 A 12"ø RG-1 (TYP 2) 22"x16" 12"x10" T63 UP VAV 16 10"x10" MECHANICAL ROOM SD-16 14"x14" 235 CFM (TYP 4) 12"x10" RG-1 (TYP 2) 14"x10" T64 SD-10 230 CFM (TYP 4) 10"x10" M 35 14"x14" VAV 15 RG-1 50 CFM 13.28 EQUIPMENT STORAGE T39 T50 101 107 103 109 MECHANICAL SPECIFIC NOTES: 3 1 PROVIDE FIRE DAMPER IN DUCTWORK PENETRATING FIRE RATED SHAFT WALLS 2 PROVIDE ACOUSTICAL LINING AS INDICATED 3 PROVIDE INACTIVE FLOOR GRILLE LENGTHS WITH BLANK-OFF PLATE TO PROVIDE CONTINUOUS LENGTH 1.9 14.3 4 PROVIDE ACOUSTICAL LAGGING MATERIAL AROUND DUCT OVER THIS SPACE 5 WRAP VAV-16 IN ACOUSTICAL LAGGING MATERIAL 2.4 3 4 5 6 7 8 9 10 11 12 13 13.2 14 14.2 15 6 PROVIDE INACTIVE GRILLE LENGTHS WITH BLANK-OFF PLATE TO PROVIDE CONTINUOUS LENGTH 7 PROVIDE 6x6 LINED TRANSFER AIR DUCT FROM MENS ROOM TO JANITORS CLOSET. MECHANICAL GENERAL WORK NOTES: Architects of Record Consultants Project Name + Location hemmler + camayd architects CECO Associates, Inc. Thomas J. McLane & Associates 409 Lackawanna Ave, Suite 400, Scranton, PA 18503 v: 570-961-1302 f: 570-961-3919 www.hc-architects.com CIVIL 507 Linden Street, Suite 200, Scranton PA 18503 P.570-342-3101 F.570-342-3940 LANDSCAPE Architecture Planning Interior Design STRUCTURAL Smith Miller Associates 239 Schyler Ave, Kingston, PA 18704 P.570-714-4984 F.570-714-4986 2300 Adams Ave, Scranton, PA 18509 10 4. ALL TRANSFER AIR DUCTS ABOVE CEILING SHALL HAVE 1" ACOUSTICAL LINING. 11 5. DISTRIBUTION SYSTEM DOWNSTREAM OF VAV BOXES (T-06, T-07, T-08, T-10, & T-15) SHALL NOT HAVE VOLUME DAMPERS AND BE ARRANGED TO BE SELF-BALANCING AS SHOWN. 12 PROVIDE LINED TRANSFER AIR DUCT ABOVE CORRIDOR CEILING INTO ELEVATOR EQUIPMENT ROOM. PROVIDE DOWN TURNED ELBOW IN SPACE AND 1-1/2 HR FIRE DAMPER PENETRATION Revision Description ADDENDUM #02 ADDENDUM #12 WCPR#09 MECHANICAL DUCTWORK PLAN TERRACE LEVEL PROVIDE VOLUME DAMPER IN RETURN DUCT TO AHU-4 LOCATE ELEVATOR EQUIPMENT ROOM EXHAUST FAN (EF-5, 6, & 11) OVER ELEVATOR EQUIPMENT. LOCATE TRANSFER AIR DUCT ON OPPOSITE DIE OF ROOM. drawn: D.M.H. checked: C.C.S. reviewed: T.C.S. 11.001 12/12/2012 M WE A L T ON H REGISTERED PROFESSIONAL CHARLES C. SMITH ENGINEER No.PE−041947−E N E MEP/FP Marywood University Learning Commons 3. SEE VAV BOX SCHEDULE ON DWG M401 FOR DUCT INLET SIZES P 8 West Market Street, Suite 1200, Wilkes-Barre, PA 18701 v: 570-825-8756 f: 570-825-3744 www.bcj.com 601 Stafford Ave, Scranton, PA 18505 P. 570-347-3668 F. 570-341-5413 9 PROVIDE 8x8 RETURN AIR TAP ABOVE CEILING WITH VOLUME DAMPER PROVIDE FULL SIZE ACOUSTICALLY LINED TRANSFER DUCT WITH DOWN TURN ELBOW. MOUNT GRILLE 7'-6" A.F.F. OF Bohlin Cywinski Jackson Rev # Date 1 1/4/2013 2 2/22/2013 3 5/2/2014 2. SEE GRD SCHEDULE ON DWG M401 FOR DUCT RUN OUT SIZES Sheet Information 12/12/2012 ISSUED FOR BID reuther + bowen 326 Ward Street, Scranton, PA 18512 P.570-496-7020 F.570-496-7021 Issues + Revisions 8 CO M MECHANICAL DUCTWORK PLAN TERRACE LEVEL 1 1/8" = 1'-0" 1. ALL RETURN DUCTWORK INSTALLED ABOVE CEILING. PROVIDE VOLUME DAMPER AT DUCT OPENING COVER WITH WIRE MESH A 2 I 1 N N S Y L V A Copyright 2012 M201 hemmler + camayd architects, p.c.