Transcript
14.1
15.2
10.5 SEE DRAWING M206 FOR ENLARGED MECHANICAL ROOM
AUDIO LAB
108
106 102 ANIMATION104 LAB
T08
SEE DRAWING M206 FOR ENLARGED MECHANICAL ROOM
22"x18"
T04 SD-10
ELEC. ROOM
AL
SD-12
2
130 CFM
18
FD
1
FD
68"x36"
RG-1
10"x10"
FD
SEE DRAWING M207 FOR ENLARGED MECHANICAL ROOM
MECHANICAL ROOM
12
28"x20"
16"x16"
255 CFM
RG-1
5
T11 T
ATC
SD-32
22"x12"
12"ø
EF-5
RG-1 30"x20"
UP
T14
B
32
12"ø
140 CFM (TYP 2) SD-13
SD-13 210 CFM
E
MEN'S RESTROOM T47
GENERAL LIBRARY STORAGE
VAV
WOMEN'S 3 RESTROOM
280 CFM
ER-1
BUILDING STORAGE ROOM
T41
RG-1
T45
70 CFM
SD-6
RG-1
115 CFM
JAN CLOSET
LC MEDIA PREVIEW
T46
T44
SD-6 LC MEDIA 115 CFM PREVIEW
RG-1
SD-6
SD-6
105 CFM
105 CFM
VAV 6
8"x8" SD-6 SD-6
50 CFM
50 CFM RG-1
T43
BROADCAST ASSISTANT T40
EEE
SD-7
SD-7
170 CFM RG-1
SD-6
260 CFM
RG-1
RG-1
45 CFM
RG-1
RG-1 SD-31
SD-7
460 CFM (TYP. 4)
RG-1 30"x22"
SD-10
SD-30
RG-31
1000 CFM (TYP. 4)
(TYP. 4)
RG-1
240 CFM (TYP. 4)
RG-1
165 CFM
D.1
D.9
RG-1
120 CFM
C.9
18"
260 CFM
160 CFM 165 CFM SD-34
SD-7
50 CFM
260 CFM
22"x18"
10"x8"
12"x10"
SD-32
VAV 8
16"x12"
SD-6
RG-1
DDD
VAV 7
SD-32
SD-14
28"
8"ø
8"x8"
VAV 4
SD-32
13.6
16
18"
RG-1 10"x10"
8"x8"
VAV 10
15.5
28"
8"x8"
VAV 9
RG-1
18"
14"x10"
6"ø
BROADCAST DIRECTOR
10"x8"
140 CFM
10"x8"
ER-2
VAV 2
8"x8"
18"x12"
8"x8"
8"x6"
12"x8"
ER-2
VAV 1
14"x10"
10"x10"
8"x8"
T52
EF-11
13.4
10"ø
785 CFM 8
11
T
175 CFM
14"x14"
24"x16"
28"x18"
T20
SD-7 EL2
TG-1
RG-1
18"
CORRIDOR
RG-1
8" ø
8"x8"
34"x18"
ELEV #2
12"x12"
150 CFM
8"x8"
100 CFM
T51
SD-7
175 CFM 16"x16"
VAV 11
VAV 5
8"x8"
150 CFM
10"x8"
SD-14
18"x12"
14"x8" 6"x6"
RG-1
T48
EF-6
SD-7
10"x8"
10"x6"
95 CFM
8"x8"
FD
T53
VAV 12
CUSTODIAL
T
T01
155 CFM (TYP 2)
8"x8"
CORRDIOR
D
10
12
LOBBY
SD-33
6"x6"
RG-1
RG-1
SD-14
12"x8"
10"x8"
T49EF-6
SD-7
10"x10"
ELEV MACH ROOM 11
145 CFM
RG-1
T62
RG-1 (TYP 2)
RG-1
FD
EF 11
ELEV LOBBY
12"x12"
26"x14"
AS/RS VAULT SD-8
UP
70 CFM
EL1
UP
RG-1
18"x16"
SD-14
9
1
18"x18"
T02
14"x14"
T61
ELEV #1
T60
ST1
75 CFM
140 CFM (TYP. 2)
AL 2
8"x8"
RG-1
ELEV LOBBY
8"ø
ELEV LOBBY
145 CFM (TYP 6) NEWS
SD-14
14"x12"
22"x12"
FCU 1
135 CFM (TYP. 4)
SD-6 28"x8"
UP
SD-16
RG-1
SD-16
FCU 2
14"x14"
DHU 1
10"x6" (TYP 6)
140 CFM (TYP 2)
VAV 13
28"
RG-1
8"x8"
18 ATC
90 CFM
RG-1
8"x8"
RG-1
8"x8"
RG-1
8"x8"
8"x8"
12"x10"
ELEV MACH11 ROOM EF
255 CFM (TYP 3)
RG-1
A.4
9
SD-32
VAV 14
10
SD-14
MECHANICAL ROOM
30"x16"
T65
C
T12
T13
TEL / DATA
STAIR #1
CAFE STORAGE
24"x20"
14"x12"
B.6
A
12"ø
RG-1 (TYP 2)
22"x16" 12"x10"
T63
UP
VAV 16
10"x10"
MECHANICAL ROOM
SD-16
14"x14"
235 CFM (TYP 4)
12"x10"
RG-1 (TYP 2)
14"x10"
T64
SD-10
230 CFM (TYP 4)
10"x10"
M 35
14"x14"
VAV 15
RG-1
50 CFM
13.28
EQUIPMENT STORAGE T39
T50
101
107 103
109 MECHANICAL SPECIFIC NOTES:
3
1 PROVIDE FIRE DAMPER IN DUCTWORK PENETRATING FIRE RATED SHAFT WALLS 2 PROVIDE ACOUSTICAL LINING AS INDICATED 3 PROVIDE INACTIVE FLOOR GRILLE LENGTHS WITH BLANK-OFF PLATE TO PROVIDE CONTINUOUS LENGTH
1.9
14.3
4 PROVIDE ACOUSTICAL LAGGING MATERIAL AROUND DUCT OVER THIS SPACE 5 WRAP VAV-16 IN ACOUSTICAL LAGGING MATERIAL
2.4
3
4
5
6
7
8
9
10
11
12
13 13.2
14 14.2
15
6 PROVIDE INACTIVE GRILLE LENGTHS WITH BLANK-OFF PLATE TO PROVIDE CONTINUOUS LENGTH 7 PROVIDE 6x6 LINED TRANSFER AIR DUCT FROM MENS ROOM TO JANITORS CLOSET.
MECHANICAL GENERAL WORK NOTES:
Architects of Record
Consultants
Project Name + Location
hemmler + camayd architects
CECO Associates, Inc.
Thomas J. McLane & Associates
409 Lackawanna Ave, Suite 400, Scranton, PA 18503 v: 570-961-1302 f: 570-961-3919 www.hc-architects.com
CIVIL
507 Linden Street, Suite 200, Scranton PA 18503 P.570-342-3101 F.570-342-3940
LANDSCAPE
Architecture Planning Interior Design
STRUCTURAL
Smith Miller Associates 239 Schyler Ave, Kingston, PA 18704 P.570-714-4984 F.570-714-4986
2300 Adams Ave, Scranton, PA 18509
10
4. ALL TRANSFER AIR DUCTS ABOVE CEILING SHALL HAVE 1" ACOUSTICAL LINING.
11
5. DISTRIBUTION SYSTEM DOWNSTREAM OF VAV BOXES (T-06, T-07, T-08, T-10, & T-15) SHALL NOT HAVE VOLUME DAMPERS AND BE ARRANGED TO BE SELF-BALANCING AS SHOWN.
12 PROVIDE LINED TRANSFER AIR DUCT ABOVE CORRIDOR CEILING INTO ELEVATOR EQUIPMENT ROOM. PROVIDE DOWN TURNED ELBOW IN SPACE AND 1-1/2 HR FIRE DAMPER PENETRATION
Revision Description ADDENDUM #02 ADDENDUM #12 WCPR#09
MECHANICAL DUCTWORK PLAN TERRACE LEVEL
PROVIDE VOLUME DAMPER IN RETURN DUCT TO AHU-4 LOCATE ELEVATOR EQUIPMENT ROOM EXHAUST FAN (EF-5, 6, & 11) OVER ELEVATOR EQUIPMENT. LOCATE TRANSFER AIR DUCT ON OPPOSITE DIE OF ROOM.
drawn: D.M.H. checked: C.C.S. reviewed: T.C.S. 11.001 12/12/2012 M
WE A L T ON H REGISTERED
PROFESSIONAL
CHARLES C. SMITH ENGINEER No.PE−041947−E
N
E
MEP/FP
Marywood University Learning Commons
3. SEE VAV BOX SCHEDULE ON DWG M401 FOR DUCT INLET SIZES
P
8 West Market Street, Suite 1200, Wilkes-Barre, PA 18701 v: 570-825-8756 f: 570-825-3744 www.bcj.com
601 Stafford Ave, Scranton, PA 18505 P. 570-347-3668 F. 570-341-5413
9 PROVIDE 8x8 RETURN AIR TAP ABOVE CEILING WITH VOLUME DAMPER
PROVIDE FULL SIZE ACOUSTICALLY LINED TRANSFER DUCT WITH DOWN TURN ELBOW. MOUNT GRILLE 7'-6" A.F.F.
OF
Bohlin Cywinski Jackson
Rev # Date 1 1/4/2013 2 2/22/2013 3 5/2/2014
2. SEE GRD SCHEDULE ON DWG M401 FOR DUCT RUN OUT SIZES
Sheet Information
12/12/2012 ISSUED FOR BID
reuther + bowen 326 Ward Street, Scranton, PA 18512 P.570-496-7020 F.570-496-7021
Issues + Revisions
8
CO M
MECHANICAL DUCTWORK PLAN TERRACE LEVEL 1 1/8" = 1'-0"
1. ALL RETURN DUCTWORK INSTALLED ABOVE CEILING. PROVIDE VOLUME DAMPER AT DUCT OPENING COVER WITH WIRE MESH
A
2
I
1
N N S Y L V A
Copyright
2012
M201 hemmler + camayd architects, p.c.