M-50 GAS DIRECT VENT FIREPLACE GENERAL APPLIANCE SPECIFICATIONS Figure 1: General Appliance Specifications
1" MIN. 394 FRAMING WIDTH
52" 8" TO VENT PIPE CENTER
30"
363 4"
1" 198
MINIMUM ROUGH FRAMING DIMENSIONS HEIGHT WIDTH DEPTH FROM UNIT BASE TO ROOM CEILING FROM UNIT BASE TO 8" MANTEL
18"
45°
1" 162
1" 162
1"
1" 212
43 4"
163 8"
735 8"
1"
47-9/16" 39-1/4" 21-1/2" 72" 50"
ADJACENT WALLS: A wall perpendicular to and in front of this fireplace's glass door surface must be at least 18 inches from the side edges of the visible glass. A wall at 45° to the glass surface and starting at this Fireplace's outer edge is permitted. Projections behind this wall (in shaded area) are permitted.
CEILING
24" MIN TO SOFFIT
8" MANTEL DEPTH AT HEIGHTS SHOWN 8" DEEP COMBUSTIBLE MANTEL
72" MIN. TO ROOM CEILING
15"
50"
50" MIN. UNIT BASE TO 8" MANTEL 9 " MIN. 4716 ROUGH FRAMING HEIGHT
387 8"
1" HEARTH PAD HEIGHT 12 (MIN R-1 RATING) IS REQUIRED
15" 14" 8"
13"
383 4"
5/8" min. from unit front edge to back edge of hearth pad. Spacer is installed on fireplace.
7" 716 615 16" 63 8"
12" 11"
9"
5" 516 413 16"
8" 7"
1" 44
6" 5"
33 4"
4"
3" 316 211" 1" 16 28
15
3" 2"
0"
0"
DISTANCE FROM FIREPLACE FACE
11" 9 16 16"
15 8"
1"
HEIGHT ABOVE CONVECTION AIR OPENING
10"
57 8"
8
9 4716
46 3/4" TO CENTERLINE OF VENT CAP
APPROVED MANTEL PROFILE
24" min. Non-combustible Hearth protection required [SEE HEARTH PROTECTION PAD R-RATING, PAGE 12]
NOTE: For every 1" this fireplace is raised off the floor, the non-combustible hearth protection pad may be reduced by 2". If this fireplace is raised off the floor more than 12", No hearth protection pad is required.