Transcript
DK802A/B Series
DK
DK
High resolution and High accuracy compact digital gauges.
• Measuring range : 2 mm • Accuracy : 1 μm, 1.5 μm • Resolution : 0.1 μm, 0.5 μm • Max.respose speed : 80m/min (Resolution : 0.1 μm)
• Magnetic principle • Excellent resistance to workshop conditions. Resistant to oil, water, dust, vibration, and shock. • Accuracy : 1 μ m, 1.5 μ m • Resolution : 0.1 μ m, 0.5 μ m • Measuring range: 5 mm • Low measuring force • Spindle can be moved vertically with an air pressure device • Easy installation. Flange type gauges also available.
250m/min (Resolution : 0.5 μm) Built-in reference point Excellent resistance to workshop conditions. Robust design for harsh environments.
•
DK802
CE29
High accuracy, compact, and slim gauges suitable for installation on machines.
LY71,LY72
DK805
CE29
DK805ALR/DK805BLR DK805ALR5/DK805BLR5
LY71,LY72
DK802AR/DK802AR5/ DK802BR/DK802BR5 LT30
LT30
MG series
DK802AR/DK802AR5/ DK802BR/DK802BR5
79.6/31.3
φ0.08 deep0.1
71.6/2.82
DK805AR/DK805BR DK805AR5/DK805BR5
φ12/0.47
71.6/31.3 5.3/0.21 21.2/0.83
8.7/0.34
79.6/31.3
4/0.26
φ8/0.31
Unit : mm/inch
M9 x P0.5
21.2/0.83
4-φ2.1 deep2.5/
Specifications DK802 Series
Output
DK802BR, DK802BLR
High-resolution models
0.1 μ m
DK805AFR, DK805AFLR, DK805AR, DK805ALR
2 mm (0.08") 1 μm
"Accuracy (at 20˚C / 68˚F)"
Output Signal pitch Resolution Measuring range Accuracy (at 20˚C/68˚F)
1.5 μ m Downward: 0.45 ± 0.25 N Horizontal: 0.40 ± 0.25 N Upward: 0.35 ± 0.25 N
Measuring force (at 20˚C / 68˚F)
80 m/min
42 m/min
250 m/min
Vibration resistance (10 to 2000 Hz)
100m/s2
Impact resistance (11 ms)
1000m/s2 IP66 (not including interpolation box and connectors)
Protective structure
0˚C to 50˚C/32˚C F to 122˚F
Operating temperature
–20˚C to 60˚C/_4˚CF to 140˚F
Storage temperature
DC +5 V ±5%
Power supply voltage
1W
Power consumption
2.5 m/8.2'
Cable length
φ”8 / 0.31”dia.
Diameter of stem Mass*1
Approx. 20 g/0.7 oz Provided with a carbide ball tip (DZ-123) Mount screw M2.5
Accessories "Output cable length(up to the electronic section)" *1: The mass indicated is the total mass excluding the cable and interpolation box.
Provided with a steel ball tip Mount screw M2.5
+P M4x5 screw (2pcs.). Installation spacer, Instruction Manual, Supplement 22 m/72.2' max.
Downward: 0.45 ± 0.25 N Horizontal: 0.40 ± 0.25 N Upward: 0.35 ± 0.25 N
100 m/min
Vacuum suction (DK802ALR / DK802ALR5 / DK802BLR / DK802BLR5)
Air driving
Reference point Maximum response speed Air driving Vibration resistance (10 to 2000 Hz) Shock resistance (11 ms) Protective structure Operating temperature Storage temperature Power supply voltage Power consumption Cable length*1 Diameter of stem Mass*2 Feeler Accessories Output cable length (up to the electronic section)
DK805BFR, DK805BFLR, DK805BR, DK805BLR DK805AFR5, DK805AFLR5, DK805AR5, DK805ALR5 DK805BFR5, DK805BFLR5, DK805BR5, DK805BLR5
A/B/Z phase voltage-differential line driver output (compliant with EIA-422) *Please see P17 Output Signal Phase Difference. 40 μm 0.1 μm 0.5 μm 5 mm (0.19") 1 μm 1.5 μm
Measuring force (at 20˚C/68˚F)
One location (at 1 mm/0.04" position of spindle movement)
Reference point
General-purpose resolution model
Model
0.5 μ m
Measuring range
10
Specifications DK805 Series
40 μ m
Resolution
Feeler
DK802BR5, DK802BLR5
A/B/Z phase voltage-differential line driver output (compliant with EIA-422)
Signal pitch
Maximum response speed
DK802AR5, DK802ALR5
Unit : mm/inch *Please refer to p54 for the details of the screw.
General-purpose resolution Flange models
High-resolution Flange models DK802AR, DK802ALR
0.34/ 8.6
φ0.08 deep0.1
Model
φ0.39
φ10/ φ035
0 −0.009/ 0 −0.004
Option : Extension cable (CK-T12:1m/3.3’, CK-T13:3m/9.8’, CK-T14:5m/16’, CK-T15:10m/32.8’)
0 −0.009/ 0 −0.004
φ9/
φ0.35
DK805AFR/DK805BFR DK805AFR5/DK805BFR5 0 φ0.37 −0.004
5.5/0.22
0.34/ 8.6
71.6/2.82
0
30.5/1.2 41.5/1.63
56.2/2.21
φ95 −0.009/
13.6/0.54
21.2/0.83
φ9/
21/0.83
M9 x P0.5 4-φ2.1 deep2.5/
ø9/ø0.35
Cable length 1,3,5,10m (39.37"/118.11"/196.85"/393.70")
13.6/0.54
ø11.8/ø0.46 ø10/ø0.39
46.2/1.82
61.6/2.43
4/0.16
21/0.83
8.6/0.34
21.2/0.83
8.7/0.34
φ10/
12.2/0.48
64.2/2.53
5.5/0.22 14/0.55
5.3/0.21
φ0.39
12.2/0.48 8.6/0.34
79.6/3.13
61.6/2.43
0
64.2/2.53
Z – Z Option : Extension cable (CE22-01:1m/3.3’, CE22-03:3m/9.8’, CE22-05:5m/16’, CE22-10:10m/32.8’)
24.3/0.96 35.5/1.4 49.5/1.95
φ9.5 −0.009/ 0 φ0.37 −0.004
B – B
DK805ALR/DK805BLR DK805ALR5/DK805BLR5
φ12/0.47
13.6/0.54
Cable length 1,3,5,10m (39.37"/118.11"/196.85"/393.70")
Cable color Red White Blue Yellow Orange Gray Green Violet
ø10/ø0.39
Signal +Vcc 0V A – A
DK805AFLR/DK805BFLR DK805AFLR5/DK805BFLR5
DK802ALR/DK802ALR5/ DK802BLR/DK802BLR5
21/0.83
50/1.97
41.5/1.63
13/0.51
Digital Gauge
Dimensions
55.5/2.19
4.8/0.16 6.2/0.24
MG series
Digital Gauge
Dimensions
13/0.51
DK805AFLR/DK805BFLR DK805AFLR5/DK805BFLR5
DZ-801 air lifter (optional) or tubing for compressed air device can be attached.
φ8/0.31
• •
DK805A/B Series
80 m/min
One location (at 1 mm/0.04" position of spindle movement) 42 m/min 250 m/min Vacuum suction ( DK805AFLR / DK805AFLR5 / DK805BFLR / DK805BFLR5 / DK805ALR / DK805BLR / DK805ALR5 / DK805BLR5 )
100 m/min
100 m/s2 1000 m/s2 IP66 (not including interpolation box and connectors) 0˚C to 50˚C/32˚F to 122˚F -20˚C to 60˚C/-4˚F to 140˚F DC +5 V ±5% 1W 2.5 m/8.2' 0 0 ø 9.50 -0.009 /0.37"-0.0004 dia. Approx. 30 g/1.06 oz Provided with a carbide ball tip (DZ-123) Mount screw M2.5 Installation spacer, Instruction Manual, Supplement
Provided with a steel ball tip Mount screw M2.5
22 m/72.2' max.
*1 : Please refer to P10 DK 802 A/B about the extension cable (Option). *2 : The mass indicated is the total mass excluding the cable and interpolation box.
11