Preview only show first 10 pages with watermark. For full document please download

Mains Cable - Elfa Distrelec

   EMBED


Share

Transcript

Mains cable Mains cable Copper unshielded , 300/500 V white Features: Class 5 flexible copper conductor For internal wiring or supply cords For use in high temperature zones Not suitable for outdoor use Specification: Cable type Mains cable Wire Code H05V2V2-F Conductor Copper Sheath colour white Shielding unshielded Conductor insulation PVC Original packaging 50 m Sheath PVC Min. bending radius, not moving 6 x line ø Temperature range 0...+90 °C Product range: Art. no. Cross-section Cores Core colours ø Sheath RND 475-00001 0.75 mm² 2 blue/brown 6.3 mm RND 475-00002 0.75 mm² 3 green/yellow/blue/brown 6.7 mm RND 475-00003 1.00 mm² 3 green/yellow/blue/brown 7 mm RND 475-00004 1.50 mm² 3 green/yellow/blue/brown 8.1 mm RND 475-00005 2.50 mm² 3 green/yellow/blue/brown 9.7 mm RND 475-00006 0.75 mm² 4 green/yellow/brown/black/grey 7.3 mm RND 475-00007 1.00 mm² 4 green/yellow/brown/black/grey 7.9 mm RND 475-00008 1.50 mm² 4 green/yellow/brown/black/grey 9 mm RND 475-00009 0.75 mm² 5 green/yellow/brown/black/grey/blue 8.1 mm Distrelec Group AG, Grabenstrasse 6, 8606 Nänikon, Switzerland, T +41 44 944 99 11, [email protected], distrelec.com