Preview only show first 10 pages with watermark. For full document please download

Mains Isolation Relays K-ry

   EMBED


Share

Transcript

Mains Isolation Relays K-RY General • 2 NO-contact*, 1 NO/NC-contact*, 2 NC-contact * Mains isolation - relay with 3mm contact gap for full switching off • Upright version • 35 mm version for standard rail mounting • Ambient temperature – 25 … + 55 °C • Soldering heat resistance 260 °C/5s • RoHS compliance Connections • Soldering pins for PCB • 6.3 mm Faston plug Drive • Direct current, monostable • AC-current, monostable Approvals • cULus (Version with 2 NO-contact) Standards • IEC 61810-1 Technical Data mechanical Technical Data electrical Dimensions L x W x H (in mm) 50,2 x 31,2 x 28,7 Shock resistance Vibration resistance 5 g, 11 ms Half sinus 5 g, 10 – 55 Hz Operating time Releasing time typical 15 ms typical 3 ms Mechanical service life (without load) Weight >10 7 cycles 55 g Max. switching capacity Max. switching current Version with 2 NO-contact AC 3.680 VA, DC *W 16 A Max. switching capacity Max. switching current version with contactset 110 or 020 AC 2.300 VA, DC *W 10 A Max. switching voltage Electrical service life (with nominal load) * see DC-switching capacity Insulation Over voltage category (Ü) III Degree of pollution (V) 2 Insulating material group II Insulation between Contact – Contact Contactset – Drive 106 Relay catalogue AC 230/240, DC *V >100.000 cycles B-I = Basic insulation V-I = Reinforced (double) insulation Nominal voltage network system AC 120/240 V AC 230/400 V V-I B-I V-I V-I Air-/ creeping distance > 3 mm > 8 mm Test voltage 50Hz/60s AC 2.500 V AC 4.000 V Mains Isolation Relays K-RY Dimensions K-RY (for PCB) K-RY (with 6,3 mm Faston plug) KOO-_3RY/11 KOO-_4RY/11 K-RY (6,3 mm and tab screen mounting) K-RY (6,3 mm for standard rail mounting) KOO-_4RY/12 KOO-_4RY/13 Standard rail Type key Special Features O Standard Drive 0 DC, neutral, monostable 1 AC, monostable Special version 1 Standard 2 tab screen mounting on housing 3 for standard rail mounting 35 mm Version 00 Standard 01 Special version K O O - 0 3 R Y _ / 1 1 - 0 0 1 0 1 4 - 2 0 0 / 0 0 1 . 0 0 Housing 0 dustproof (RTII) Contactset table Connections 3 Soldering pins for PCB 4 Faston plug 6,3 mm Number of contacts NO/NC/CO-contacts 200 (16 A) 110 (10 A) 020 (10 A) Coils See coil table NC-contact Size 1 Standard CO-contact AgCdO AgCdO AgCdO AgCdO Soldering pin Faston plug Soldering pin Faston plug DC-Coil 001 003 002 DC-Coil 007 009 008 Contactset-number See contactset table NO-contact AC-Coil 004 006 possible AC-Coil 010 012 011 AgCdO + 10 µm A Soldering pin DC-Coil 014 possible possible Relay catalogue W Soldering pin Contact DC-Coil material 013 015 possible contact set number 107 Mains Isolation Relays K-RY All values at ambient temperature Tu = 20 °C Coil table Number of contacts 200 Coil-No. 001028 001026 001021 001014 001068 001009 001006 DC-Drive Coil-No. Number of contacts 110 und 020 001031 001028 001022 001016 001012 001011 001006 DC-Drive Coil-No. Number of contacts 200, 110 und 020 001136 001128 001121 001116 001114 001111 001106 AC-Drive Resistance R/Ω 17 28 80 440 1.380 2.780 6.700 Resistancetolerance ± 15% 15% 15% 15% 15% 23% 23% U1/V Resistance R/Ω 12 17 63 260 1.050 1.730 6.700 Resistancetolerance ± 15% 15% 15% 15% 15% 15% 23% U1/V Resistance R/Ω 5 17 80 260 445 1.730 6.700 3,9 4,9 8,7 19,3 35,2 51,3 81,7 U2/V Urück/V 7,4 9,6 16,2 38,3 67,5 93,0 144,4 U2/V 3,5 4,4 8,5 17,7 34,4 43,4 92,6 0,8 1,0 1,7 3,8 6,8 9,0 14,2 Urück/V 6,2 7,4 14,4 29,3 58,8 75,5 144,4 Umin/V Umax/V 4,8 9,6 19,2 33,6 48,0 88,0 184,0 6,6 13,2 26,4 45,0 66,0 121,0 253,0 0,2 0,3 0,6 1,2 2,4 3,0 5,7 Printing Unom/V 5 6 12 24 48 70 110 Printing Unom/V 5 6 12 24 48 60 115 Printing Unom/V 6 12 24 42 60 110/115 220/230 Coil designed for 50 Hz, 100% ED at Tu +20 °C U 1: U 2: U rück: Minimum operating voltage with consideration of coil self heating Thermal restricted maximum coil voltage Releasing voltage Further coils are possible and available Running types Article-No. RY_-4407 RY_-4412 RY_-4417 RY_-4800 RY_-4801 RY_-4802 RY_-4806 RY_-4808 RY_-4820 RY_-4824 RY_-4839 RY_-5664 108 Relay catalogue Type key KOO-04RY_/12-001014-200/001.00 KOO-03RY_/11-001014-200/001.00 KOO-14RY_/12-001106-200/010.01 KOO-14RY_/11-001106-200/010.00 KOO-03RY_/11-001014-200/001.00 KOO-13RY_/11-001106-200/004.00 KOO-04RY_/11-001014-200/007.00 KOO-03RY_/11-001021-200/001.00 KOO-04RY_/12-001014-200/007.00 KOO-04RY_/13-001014-200/007.00 KOO-03RY_/11-001026-200/014.00 KOO-14RY_/12-001106-200/010.00 Printing Unom DC 24 V DC 24 V AC 230 V AC 230 V DC 24 V AC 230 V DC 24 V DC 12 V DC 24 V DC 24 V DC 6 V AC 230 V U1/V 19,3 19,3 184,0 184,0 19,3 184,0 19,3 8,7 19,3 19,3 4,9 184,0 U2/V 38,3 38,3 253,0 253,0 38,3 253,0 38,3 16,2 38,3 38,3 9,6 253,0 Urück/V 3,8 3,8 3,8 3,8 1,7 3,8 3,8 1,0 Mains Isolation Relay K-RY 2 NO (200), 16 A Connection grid View on soldering side 2 NC (020), 10 A 1 NO / 1 NC (110), 10 A current (A) Contactgap: Arc duration 0 Switching voltage DC-switching capacity current (A) Diagrams 0 Switching cycles Electrical service life Relay catalogue 109