Preview only show first 10 pages with watermark. For full document please download

Man0532-04

   EMBED


Share

Transcript

DQM701 / 706 12 NOV 2003 Page 1 32 Digital Outputs HE450DQM701 / HE459DQM701 24VDC Out, Negative Logic HE459DQM706 24VDC Out , Positive Logic SmartStix For electronic information including the GSD File, see www.SmartStix.com. This product has a Programming Reference (SUP0552). HE450 denotes a non-removable terminal strip; HE459 denotes a removable terminal strip. 1 SPECIFICATIONS DQM701 / 706 Outputs Number of output points Commons per Module Operating Voltage Rated Load Voltage Maximum Load Current per channel Max. DQM Inrush 701 Current DQM per 706 channel OFF Leakage Current Maximum Voltage Drop during ON circuit Internal power Consumption (mA) General Storage Temperature Operating Temperature Atmosphere Operating and Storage Humidity 32 2 24VDC 24VDC 0.1A Max. per output; 2A per common 0.4A, 10ms. External Power Supply Voltage Current OFF to ON Response ON to OFF Response DQM Output 701 Type DQM 706 Operating Indicator 24VDC ± 10%(ripple voltage: 4Vp-p or less) 30mA (TYP, All points ON) 0-3ms. or less 0-3ms. or less Sinking Sourcing LED turns on during ON state of output External connections Terminal block connector (M3 x 6 screws) 0.1mA or less Common Method 16 points / COM 1.5VDC(0.5A) Isolation methods Photo Coupler 1A, 10ms 380mA -25° to 70° C 0° to 55° C Free from corrosive gases and excessive dust 5 to 95% Noncondensing Weight DQM701 DQM706 Pollution degree Internal power Consumption (mA) Cooling method Weight 8.9oz. (255g) 10.0oz. (285g) 2 or lower 380mA Self-cooling 8.4 (239G) MAN0532-04 Information is subject to change without notice. Page 2 12 NOV 2003 DQM701 / 706 Vibration Occasional Vibration Frequency 10 ≤ f < 57 Hz 57 ≤ f ≤ 150 Hz Acceleration Amplitude - 0.075 mm 9.8 m/s 2 {1G} - Sweep Count 10 times in each direction for X,Y,Z Continuous Vibration Frequency Acceleration Amplitude 10 ≤ f < 57 Hz - 0.035 mm 57≤ f ≤ 150 Hz 4.9 m/s 2 {0.5G} - 10 times in each direction for X,Y,Z Shocks Maximum shock acceleration 147 m/s 2 {15G} Duration Time Pulse Wave Sweep Count 11 ms. Half sine wave pulse (3 times in each of X, Y, Z directions) Noise Immunity AC: ± 1,500VDC DC: ± 900VDC Voltage: 4kV (contact discharge) Square wave impulse noise Electrostatic Discharge Radiated electromagnetic field Fast Transient Burst Noise 27 – 500MHz, 10V/m Severity level Voltage 2 All power modules 2 kV Digital I/Os (Ue ≥24V) 1 kV Digital I/Os (Ue < 24 V) Analog I/Os Communication I/Os 0.25 kV DIMENSIONS 0.18 [4.6mm] 0.31 [7.9mm] 0.31 [7.9mm] 1.62 [41.1mm] 6.61 [167.9mm] 6.95 [176.5mm] Information is subject to change without notice. 1.53 [38.9mm] HExx0- Without Removable Terminal 1.87 [47.5mm] HExx9-With Removable Terminal DQM701 / 706 3 12 NOV 2003 Page 3 WIRING 24+ Pin 24C 24+ Q2 FG Q4 24C Q6 Q1 Q2 Q3 Q4 Q5 Q6 Q7 Q8 Q9 Q10 Q11 Q12 Q13 Q14 Q15 Q16 FG LOAD Q1 LOAD LOAD Q3 LOAD Q5 LOAD Q7 LOAD Q9 LOAD Q11 LOAD Q13 LOAD Q15 LOAD LOAD Q8 LOAD Q10 LOAD 24VDC Q12 LOAD Q14 LOAD Q16 LOAD C1 Q17 LOAD Q18 LOAD Q19 LOAD Q20 LOAD Q21 LOAD Q22 LOAD Q23 LOAD Q24 LOAD Q25 LOAD Q26 LOAD LOAD 24VDC LOAD C1 Q29 Q17 Q18 Q19 Q20 Q21 Q22 Q23 Q24 Q25 Q26 Q27 Q28 Q29 Q30 Q31 Q32 Q30 LOAD Q31 LOAD LOAD Q27 Q28 LOAD Q32 C2 V+ 006DQM006 C2 V+ Information is subject to change without notice. Signal DQM701 24V Power Supply Frame Ground Power Supply Return Output 1 Output 2 Output 3 Output 4 Output 5 Output 6 Output 7 Output 8 Output 9 Output 10 Output 11 Output 12 Output 13 Output 14 Output 15 Output 16 Isolated Common 1 Output 17 Output 18 Output 19 Output 20 Output 21 Output 22 Output 23 Output 24 Output 25 Output 26 Output 27 Output 28 Output 29 Output 30 Output 31 Output 32 Isolated Common 2 Isolator Power Page 4 12 NOV 2003 DQM701 / 706 Pin 24+ FG LOAD Q1 LOAD Q3 LOAD LOAD 24VDC LOAD Q5 LOAD Q7 LOAD Q9 LOAD Q11 LOAD Q13 LOAD Q15 LOAD LOAD 24C 24 FG Q2 24C* Q4 Q6 Q8 Q10 LOAD Q12 LOAD Q14 LOAD Q16 LOAD C1 Q17 LOAD Q18 LOAD Q19 LOAD Q20 LOAD 24VDC Q21 LOAD Q22 LOAD Q23 LOAD Q24 LOAD Q25 LOAD Q26 LOAD Q27 LOAD Q28 LOAD Q29 LOAD Q30 LOAD Q31 LOAD LOAD Q32 C2 0V 006DQM008-R1 Note: If desired, C1 and C2 can use a single supply. Q1 Q2 Q3 Q4 Q5 Q6 Q7 Q8 Q9 Q10 Q11 Q12 Q13 Q14 Q15 Q16 C1 Q17 Q18 Q19 Q20 Q21 Q22 Q23 Q24 Q25 Q26 Q27 Q28 Q29 Q30 Q31 Q32 C2 0V Information is subject to change without notice. Signal DQM706 24V + Frame Ground 24V Common (*Do not Connect) Output 1 Output 2 Output 3 Output 4 Output 5 Output 6 Output 7 Output 8 Output 9 Output 10 Output 11 Output 12 Output 13 Output 14 Output 15 Output 16 Isolated Common 1 Output 17 Output 18 Output 19 Output 20 Output 21 Output 22 Output 23 Output 24 Output 25 Output 26 Output 27 Output 28 Output 29 Output 30 Output 31 Output 32 Isolated Common 2 Isolated Power Negative DQM701 / 706 12 NOV 2003 4 INTERNAL WIRING a. DQM701 I/O Connector Page 5 SmartStix V+ Field Side Q32 From Controller Q17 From Controller Isolated C2 Q16 From Controller Q1 From Controller Isolated C1 Information is subject to change without notice. Page 6 b. 12 NOV 2003 DQM701 / 706 DQM706 I/O Connector SmartStix C1 From Controller Field Side Q17 – Q32 Typical C2 From Controller Q1 – Q16 Typical 0V Information is subject to change without notice. DQM701 / 706 5 12 NOV 2003 Page 7 SWITCHES Setting Address Switches: Profibus addresses are set using the decimal number system from 1 to 99. Set a unique Network ID by inserting a small Phillips screwdriver into the two identical switches as shown in the example. Use this switch to set the Low Digit – has an x1 multiplier. Use this switch to set the High Digit –has an x10 multiplier. Power and Diagnostic LEDs SmartStix I/O HI (x10) 7 5 6 6 7 8 9 10 I/O Status LEDs 9 12 13 14 15 006DIM001 1 2 3 8 2 3 8 7 0 7 9 1 4 4 5 6 0 11 4 5 2 3 4 4 3 0 1 8 2 3 2 9 0 1 8 1 LO (x1) 7 ERR 9 RDY 5 6 RUN 5 6 Close-up of Switches 6 LEDs Communication LED MEANING RUN Displays the status of the power RDY Displays the communication status of the communication module ERR Displays abnormal condition of communication module Information is subject to change without notice. 16 Page 8 7 12 NOV 2003 DQM701 / 706 NETWORK CABLE For detailed network information, refer to www.profibus.org. a. A SmartStix module uses a 9-pin D-sub plug connector for its DP port. The pin assignment of the plug connector and the wiring are shown below. Station 1 Rx/TxD-P V+ DGND Rx/TxD-N 3 6 5 8 Station 2 Line B 3 6 5 8 Line A Shielding Protective Ground b. It is necessary to terminate both ends of the network. Both terminations must have power to them to insure proper operation of the network. The following diagram illustrates the correct connection for the termination resistors. The diagram is for illustrative purposes only. Note: Cabling and connectors need to be PTO-approved to achieve the desired performance results. VP(6) Line Termination 390 Ohm B-Line (3) 220 Ohm Internal A-Line (8) 390 Ohm GND(5) c. The shield braiding (and if present, the shield foil) must be connected to protective ground on both sides and must have good conductivity via shield clamps that cover as large an area as possible. In addition, it is recommended that the data lines be kept separate from all high-voltage cables. 8 INSTALLATION / SAFETY a. b. All applicable codes and standards need to be followed in the installation of this product. For I/O wiring (discrete), use the following wire type or equivalent: Belden 9918, 18 AWG or larger. c. For detailed installation information, refer to www.profibus.org. Warning: Consult user documentation. Information is subject to change without notice. Warning: Electrical Shock Hazard. DQM701 / 706 9 12 NOV 2003 TECHNICAL ASSISTANCE For assistance, contact Technical Support at the following locations: North America: (317) 916-4274 www.heapg.com Europe: (+) 353-21-4321-266 www.horner-apg.com Information is subject to change without notice. Page 9 Page 10 12 NOV 2003 NOTES Information is subject to change without notice. DQM701 / 706