Transcript
YELLOW
39
5 ORANGE
6 GREEN 38
Temp. and Humidity Controller Part #8403-060 D/YO
Purple/White
W1/E
D/YO
Purple/White
W1/E
Red/Yellow
Y2
Purple
A
Brown/White
Red/Yellow
G
Orange
Y2
Purple
Y1
Yellow
A
Brown/White
O/B
Blue
W2
Brown
G
Orange
Y1
Yellow
O/B
Blue
W2
Brown
R
Red/White
C
Black/White
L
Pink
PLUG #2 1 2 3 4 5 6 7 8 9 10 11 12
R
Red/White
C
Black/White
L
Pink
4115-102 A
PLUG #2 1 2 3 4 5 6 7 8 9 10 11 12
Temp. and Humidity Controller Part #8403-060 Red 24VAC Black Analog Out
"D" THERMOSTAT OPTION
Yellow Brown
Red Black Yellow Brown Orange Green
PLUG #1 1 2 3 4 5 6
Orange Green
4115-100 A
CO2 Controller Part #8403-056
"H" THERMOSTAT OPTION
4115-101 A
32
2 3
12 11 10 9 8 7 6 5 4 3
2 1
BLACK/WHITE
LPC LPC
RED
YELLOW 19
4 5
3 2 1
BLACK/ WHITE 39 45
35
35
20
36
36
High Speed Solenoid
BLACK/WHITE
BLUE
PURPLE
BLACK/WHITE
REMOVE WIRE FROM TERMINAL Y2 AND TAPE OFF WHEN LOWER FULL LOAD CFM DESIRED
L2
Step Down Transformer
BLACK
53 Three way Valve
STEPDOWN TRANSFORMER CLASS CC FUSE
1
BLUE/WHITE BLUE/BLACK RED
48
Reversing Valve
L1
L3
Hi Pressure Control
YELLOW
Low Pressure Control
Low Pressure Control
Compressor 4113-301
99
NO ERV 3.2 3.2 3.2 5
2 3
BLUE
27
REMOVE JUMPER WHEN CS2000 ENERGY MONITOR IS INSTALLED
1
OPTIONAL 3 PIN PLUG FOR ERV
27
FOR ANTIFREEZE LOOP APPLICATIONS, CHANGE LOW PRESSURE SWITCH TO YELLOW LEADS ON YELLOW WIRES COMING OFF OF COMPRESSOR CONTROL MODULE "LPC" TERMINALS
W / ERV 5 5 7 7
C 1
38
27
18 Check Light
12 PIN VENT PLUG
MODEL QW2S QW3S QW4S QW5S
ALR
Y
39
Compressor Contactor
BLACK 45
RED
BLACK/WHITE
460 VOLT PACKAGE UNIT DIAGRAM
1
T3
BLACK
BLACK
39
T2
CC
33 Transformer
Purple/White
T1
24
HPC
Fuse Block
COM
L3
38
31 460V RED
15
L2
YELLOW
C
L1
YELLOW
55
Comp. Control Module
R
48
27
GREEN
BLACK/WHITE
Green
34
37
BLUE
R
42
BLUE
54
41
PINK
44
L3
YELLOW
RED/ WHITE
38
BROWN
RED/WHITE
L2
43
BLACK
Orange
"X" THERMOSTAT OPTION
BLACK
GREEN
PINK
RED/WHITE
BLACK/WHITE
BROWN/WHITE
BROWN
BLUE
RED/ WHITE
RED/WHITE
6 PIN CO2 PLUG 27
L1
YELLOW/RED
53
RED/WHITE
33
C
Phase Monitor
21
RED BLACK
BLACK
12 LOW VOLTAGE STRIP
2
BLACK/WHITE
4
Brown
40
Y
Yout
YELLOW
4
34
10
RED
DEHUM RELAY
5
PURPLE
3
Yellow
GRAY
ORANGE
PURPLE
YELLOW 1
14
10 56
2
Red Black Yellow Brown Orange Green
Black Analog Out
10
PINK
10
10
RED/WHITE
Red
4115-105
3
10
24VAC
"K" THERMOSTAT OPTION
BROWN RED/WHITE
10
PURPLE
53
BLUE/BLACK
1
Orange
BLUE
Terminal Strip
CO2 Controller Part #8403-056
Green
RED/WHITE BLACK/WHITE
30
YELLOW
Ground Terminal 4
Rotary Disconnect
27
RED
Pink
BLUE BROWN
5 YELLOW
YELLOW
L
BLUE
ORANGE YELLOW YELLOW
46 Term. Block
10
RED
L D/YO
BROWN/WHITE
50
YELLOW/BROWN
C
Black/White
BROWN/WHITE
RED
Red/White
RED/YELLOW
RED/YELLOW PURPLE PURPLE
RED
C
PLUG #1 1 2 3 4 5 6
YELLOW
YELLOW
Brown
BLACK 29
RED
Brown
R
RED 28
BLACK/WHITE
Analog Out
W2
R
3
55
BLACK BLACK
Black Yellow
W2
ORANGE 54
RED RED GREEN
24VAC
Blue
9 10 11 12
Red Black Yellow Brown Orange Green
Red
O
8
CO2 Controller Part #8403-056
O/B
53
YELLOW
Pink
Yellow
5
L1 L2 L3
460-60-3 POWER SOURCE
5 PIN PLUG FOR INDOOR BLOWER MOTOR
4
BROWN/WHITE
PINK
Black/White
L
Y1
7
C
Y1
10
PURPLE/WHITE
RED/WHITE
Red/White
12 PIN PLUG FOR THERMOSTAT 10
5 6
R
Orange
4
Brown
W2
Brown/White
3
Blue
O
A G
YELLOW
Yellow
A G
3
10
BROWN/WHITE
Y1
PLUG #2 1 2 3 4 5 6 7 8 9 10 11 12
52
51
2
Orange
Purple
1
Brown/White
Red/Yellow
Y2
PURPLE
Purple
A G
E
Y2
BROWN
Y2
W1/E
BLACK/WHITE
Red/Yellow
BLACK/WHITE BLACK/WHITE
E
Terminal Block #1 ("A" Ctrl. Opt. Only)
11
2
O1 Y Y1 C
9 13 2
BLACK/WIHTE
Low Voltage Terminal Strip
Low Voltage Terminal Strip
1 10 6
YELLOW
2
FREEZE THRMOSTAT
RED/WHITE
DEHUM. CONTROL 49
Temp. and Humidity Controller Part #8403-060
14 12 15 3
BLACK
BLACK/WHITE
16 PIN PLUG FOR INDOOR BLOWER MOTOR 10
BLACK
Wire Identification numbers for Bard use only.
! WARNING USE COPPER CONDUCTORS ONLY SUITABLE FOR AT LEAST 75° C.
Factory Field Optional !
DANGER
*ELECTRICAL SHOCK HAZARD *DISCONNECT POWER BEFORE SERVICING.
High Voltage Low Voltage
COMPOSITE WIRING DIAGRAM 460-60-3
Bard Mfg. Co. Bryan, Ohio
4113C301 B