WIRING DIAGRAM R6GP-120(C/D) SERIES 208-230/460/575 VOLT NOTES: 1. This wire replaced by autotransformer when used. 2. For “C” Series Models only. For 208 VAC operation remove wire at 240V tap and place on 208V tap. 3. Wires attached to normally open contacts of auxillary switch. GND BL/WH STRIPE L1 YE/BL STRIPE L2 RD/BL STRIPE RD/BL STRIPE RED YE/BL STRIPE BL/WH STRIPE BLOWER TIME-DELAY BK T2 PRI. 3 1 2 4 3 RED 1 LOWER SECONDARY LIMIT YELLOW TYP. INDOOR R THERMOSTAT Y1 TERMINALS Y2 G W2 W1 R Y1 Y2 G W2 W1 C RED GREY BLUE LOW VOLTAGE CONNECTIONS RED FLAME ROLLOUT SWITCH ORANGE BLUE CONTROL WIRING LEADS REFER TO INSTALLATION INSTRUCTIONS FOR CONNECTION TO INDOOR THERMOSTAT ¢710748>¤ 1 2 3 4 5 6 7 8 ECONOMIZER PLUG 9 10 11 12 13 14 15 2 3 4 5 6 7 8 FACTORY JUMPER PLUG SEE ECONOMIZER INSTALLATION INST. FOR DETAILS) L3 RED L2 GND V2 or COM RED GAS VALVE C1 GV2 GV1 C2 3 MIN TDR 1 BK INDUCER MOTOR RELAY BK BLACK 3 6 9 B 1 4 7 A WHITE WHITE BLACK 3 BK AUTOTRANSFORMER (460 AND 575 MODELS ONLY) LEGEND: FIELD WIRING LOW VOLTAGE HIGH VOLTAGE WHITE WHITE 9 10 11 12 13 14 15 BROWN (REMOVE FOR ECONOMIZER OPERATION- WHITE V1 or MV BLACK 1 YELLOW S1 or FS HV BROWN BLACK TH or W WH 230V OR BROWN STG. 1 EVAP FRE-STAT IGNITION CONTROL INDUCER MOTOR 5 2 WHITE L.P. SWITCH 5 6 4 BLACK H.P. SWITCH 3 BLOWER 1 LIMIT-RELAY BROWN GREEN 6 MAX TEMP LIMIT GND BK BR RED BLOWER RELAY 4 2 BLACK BR BLACK RED STG. 2 EVAP FRE-STAT GREEN BR BK FLAME SENSOR BR L.P. SWITCH BR IGNITOR YE BR RED H.P. SWITCH BR T3 RED RED BR T2 T1 24V SEC. T2 BLUE BL BLACK RD/BL STRIPE T1 T1 BLACK SEE NOTE 4 T2 WHITE BK T3 BLACK SEE 1ST NOTE 3 SEE STAGE NOTE 4 COMP. RELAY CCH1 T1 INDOOR BLOWER RELAY BLUE T2 T3 BK BR L1 L1 RED BK T3 T3 R BR T1 L2 L2 RED BR T1 YE S L3 CCH2 RED BK C R T2 L1 BLUE T3 L2 SEE NOTE 2 SEE NOTE 3 L3 BLUE YELLOW S BR L3 BK T1 BK YE BK C BLACK BLACK TRANSFORMER T2 RED BLACK 2ND STAGE COMP. RELAY L1 YELLOW BLACK BLACK BLACK BLACK WHITE RED L2 BLACK WHITE SEE NOTE 1 BLACK RED BLACK L3 OUTDOOR FAN RELAY 7. If any of the original wire as supplied with the furnace must be replaced, it must be replaced with wiring material having a temperature rating of at least 105C. 8. For supply wire ampacities and overcurrent protection, see unit rating label. 4. Wires attached to normally closed contacts of auxillary switch. 5. Disconnect all power before servicing. 6. For supply connections use copper conductors only. BLACK TO FIELD SUPPLIED DISCONNECT (3 PHASE POWER ONLY) THREE PHASE 60 Hz BLACK 7107480 02/08