Transcript
REVISIONS REV
DESCRIPTION
AF
OSS SIZE
ADDED 3051CFx AND 2051CFx
CHG.NO.
APP'D
DATE
DSI1003150
JR
02/15/10
(SEE TABLE/SHT 2) RF MOUNTING FLANGE & WELD FTG. (SEE TABLE/SHEET 2 FOR SIZES) STUDS, NUTS & GASKET
3
5.50 (19.7) MAX.
DIA. 'O' (SEE TABLE/SHT 2) 9.00 (228.6) MAX. HIGH PRESSURE INSTRUMENT VALVE
OPTIONAL RTD PORT
LOW PRESSURE INSTRUMENT VALVE
3 SENSOR SIZE 1 LOCKING PIN
FLOW
RF SENSOR FLANGE (SEE TABLE/SHT 2 FOR SIZE)
WALL
EQUALIZER VALVE
ODH ODF
VALVE BONNET ASSY
ID
OW
FL
INTEGRAL MOUNT HEAD OPTION
ODP
INTEGRAL MOUNT WITH OPPOSITE SIDE SUPPORT
NOTICE
FOR ACCURATE FLOW MEASUREMENT THE CORRECT HOLE SIZE IN PIPE MUST BE:
3/4
(150# THRU 600# ANSI SHOWN)
(19mm)
INCH
DO NOT DRILL OVERSIZE DO NOT TORCH CUT HOLE
*ALL DIMENSIONS ARE NOMINAL AND ARE FOR REFERENCE ONLY
®
TYPE I
*UNLESS OTHERWISE SPECIFIED DIMENSIONS IN INCHES (MM)
jpaylor
DR.
BOULDER, COLORADO
4/1/05
TITLE DIMENSION DRAWING, MODEL 485 ANNUBAR
APPROVAL M.MONTGOMERY DRAWING TAGGING SPECIALS
6/15/05 SIZE
FLOWMETER (3051SFA, 3051CFA 2051CFA, 3095MFA) SENSOR SIZE 1 FLANGED 150# - 2500# ANSI
A
SCALE: NONE
DRAWING NO.
00485-1011
SHEET
1
OF
5
3
NPT THREADED FTG.
ODP
WELD FTG.
ODP OSS SIZE
OSS SIZE
3
WELDED OPPOSITE SIDE SUPPORT CUP
NPT THREADED OPPOSITE SIDE SUPPORT CUP
TIP OPTION 'D'
TIP OPTION 'C'
EXTENDED TIP/NPT THREADED
EXTENDED TIP/WELDED
OPPOSITE SIDE SUPPORT OPTIONS
® BOULDER, COLORADO
SIZE
A
FSCM.NO.
SCALE: NONE WT.
DRAWING NO.
00485-1011 SHEET
2
OF
5
1-1/2". RF MOUNTING FLANGE & WELD FTG. (SEE TABLE/SHT 2 FOR SIZES) GASKETS STUDS & NUTS SENSOR SIZE 1
LOW PRESSURE INSTRUMENT CONNECTION HIGH PRESSURE INSTRUMENT CONNECTION
RF SENSOR FLANGE (SEE TABLE/SHT 2 FOR SIZES) 3
3
ODF + BFT +.125(3,2) ODH
FLOW
ID ODF WALL
REMOTE MOUNT HEAD OPTION REMOTE MOUNT FLANGED OPPOSITE SIDE SUPPORT
NOTICE
FOR ACCURATE FLOW MEASUREMENT THE CORRECT HOLE SIZE IN PIPE MUST BE:
3/4
FLANGED OPPOSITE SIDE SUPPORT ASSY.
(19mm)
INCH
DO NOT DRILL OVERSIZE DO NOT TORCH CUT HOLE
ALSO AVAILABLE FOR HIGH PRESSURE APPLICATIONS (150# THRU 600# ANSI SHOWN)
® BOULDER, COLORADO
SIZE
A
SCALE:
FSCM.NO. 1:1
WT.
DRAWING NO.
00485-1011 SHEET:
3
of
5
3051SMV TRANSMITTER
EQUALIZER VALVE
3051SFA, STD HARDWARE TEMP WIDTH WIDTH
FLOWMETER
HEIGHT
WIDTH
2051CFA
7.03 [178,5]
5.50 [139,7]
3051CFA
7.1 (181)
5.67 [144,0]
3051SFA
8.53 (216.7)
5.67 [144,0]
3095MFA
7.1 (181)
5.67 [144,0]
TEMP WIDTH
10.09 [256,3]
HEIGHT
LOW PRESSURE INSTRUMENT VALVE
HIGH PRESSURE INSTRUMENT VALVE
®
485/3051SFA/3095MFA INTEGRAL MOUNT HEAD
3051SFA SHOWN
BOULDER, COLORADO
SIZE
A
SCALE:
FSCM.NO. 1:1
WT.
DRAWING NO.
00485-1011 SHEET:
4
of
5
RF MOUNTING FLANGE & WELD FTG. (SEE TABLE/SHT 2 FOR SIZES) STUDS, NUTS & GASKET
OSS SIZE
RF SENSOR FLANGE (SEE TABLE/SHT 2 FOR SIZE)
(SEE TABLE/SHT 2 FOR SIZES)
1/2" SW OR NPT PORTS
ABOVE 600# ANSI SHOWN
SENSOR SIZE 1 3
900# & ABOVE STYLE HEAD LOW PRESSURE INSTRUMENT CONNECTION
HIGH PRESSURE INSTRUMENT CONNECTION
ID
ODH
FLOW
ODP
ODF WALL
W
FLO
NOTICE
FOR ACCURATE FLOW MEASUREMENT THE CORRECT HOLE SIZE IN PIPE MUST BE:
3/4
(19mm)
INCH
HIGH PRESSURE, REMOTE MOUNT HEAD OPTION
2500# OPPOSITE SIDE SUPPORT
HI-PRESSURE REMOTE MOUNT WITH OPPOSITE SIDE SUPPORT
DO NOT DRILL OVERSIZE DO NOT TORCH CUT HOLE
(900# & ABOVE ANSI SHOWN)
® BOULDER, COLORADO
SIZE
A
FSCM.NO.
SCALE: NONE WT.
DRAWING NO.
00485-1011 SHEET
5
OF
5