Preview only show first 10 pages with watermark. For full document please download

Manual 10803125

   EMBED


Share

Transcript

REVISIONS REV DESCRIPTION AF OSS SIZE ADDED 3051CFx AND 2051CFx CHG.NO. APP'D DATE DSI1003150 JR 02/15/10 (SEE TABLE/SHT 2) RF MOUNTING FLANGE & WELD FTG. (SEE TABLE/SHEET 2 FOR SIZES) STUDS, NUTS & GASKET 3 5.50 (19.7) MAX. DIA. 'O' (SEE TABLE/SHT 2) 9.00 (228.6) MAX. HIGH PRESSURE INSTRUMENT VALVE OPTIONAL RTD PORT LOW PRESSURE INSTRUMENT VALVE 3 SENSOR SIZE 1 LOCKING PIN FLOW RF SENSOR FLANGE (SEE TABLE/SHT 2 FOR SIZE) WALL EQUALIZER VALVE ODH ODF VALVE BONNET ASSY ID OW FL INTEGRAL MOUNT HEAD OPTION ODP INTEGRAL MOUNT WITH OPPOSITE SIDE SUPPORT NOTICE FOR ACCURATE FLOW MEASUREMENT THE CORRECT HOLE SIZE IN PIPE MUST BE: 3/4 (150# THRU 600# ANSI SHOWN) (19mm) INCH DO NOT DRILL OVERSIZE DO NOT TORCH CUT HOLE *ALL DIMENSIONS ARE NOMINAL AND ARE FOR REFERENCE ONLY ® TYPE I *UNLESS OTHERWISE SPECIFIED DIMENSIONS IN INCHES (MM) jpaylor DR. BOULDER, COLORADO 4/1/05 TITLE DIMENSION DRAWING, MODEL 485 ANNUBAR APPROVAL M.MONTGOMERY DRAWING TAGGING SPECIALS 6/15/05 SIZE FLOWMETER (3051SFA, 3051CFA 2051CFA, 3095MFA) SENSOR SIZE 1 FLANGED 150# - 2500# ANSI A SCALE: NONE DRAWING NO. 00485-1011 SHEET 1 OF 5 3 NPT THREADED FTG. ODP WELD FTG. ODP OSS SIZE OSS SIZE 3 WELDED OPPOSITE SIDE SUPPORT CUP NPT THREADED OPPOSITE SIDE SUPPORT CUP TIP OPTION 'D' TIP OPTION 'C' EXTENDED TIP/NPT THREADED EXTENDED TIP/WELDED OPPOSITE SIDE SUPPORT OPTIONS ® BOULDER, COLORADO SIZE A FSCM.NO. SCALE: NONE WT. DRAWING NO. 00485-1011 SHEET 2 OF 5 1-1/2". RF MOUNTING FLANGE & WELD FTG. (SEE TABLE/SHT 2 FOR SIZES) GASKETS STUDS & NUTS SENSOR SIZE 1 LOW PRESSURE INSTRUMENT CONNECTION HIGH PRESSURE INSTRUMENT CONNECTION RF SENSOR FLANGE (SEE TABLE/SHT 2 FOR SIZES) 3 3 ODF + BFT +.125(3,2) ODH FLOW ID ODF WALL REMOTE MOUNT HEAD OPTION REMOTE MOUNT FLANGED OPPOSITE SIDE SUPPORT NOTICE FOR ACCURATE FLOW MEASUREMENT THE CORRECT HOLE SIZE IN PIPE MUST BE: 3/4 FLANGED OPPOSITE SIDE SUPPORT ASSY. (19mm) INCH DO NOT DRILL OVERSIZE DO NOT TORCH CUT HOLE ALSO AVAILABLE FOR HIGH PRESSURE APPLICATIONS (150# THRU 600# ANSI SHOWN) ® BOULDER, COLORADO SIZE A SCALE: FSCM.NO. 1:1 WT. DRAWING NO. 00485-1011 SHEET: 3 of 5 3051SMV TRANSMITTER EQUALIZER VALVE 3051SFA, STD HARDWARE TEMP WIDTH WIDTH FLOWMETER HEIGHT WIDTH 2051CFA 7.03 [178,5] 5.50 [139,7] 3051CFA 7.1 (181) 5.67 [144,0] 3051SFA 8.53 (216.7) 5.67 [144,0] 3095MFA 7.1 (181) 5.67 [144,0] TEMP WIDTH 10.09 [256,3] HEIGHT LOW PRESSURE INSTRUMENT VALVE HIGH PRESSURE INSTRUMENT VALVE ® 485/3051SFA/3095MFA INTEGRAL MOUNT HEAD 3051SFA SHOWN BOULDER, COLORADO SIZE A SCALE: FSCM.NO. 1:1 WT. DRAWING NO. 00485-1011 SHEET: 4 of 5 RF MOUNTING FLANGE & WELD FTG. (SEE TABLE/SHT 2 FOR SIZES) STUDS, NUTS & GASKET OSS SIZE RF SENSOR FLANGE (SEE TABLE/SHT 2 FOR SIZE) (SEE TABLE/SHT 2 FOR SIZES) 1/2" SW OR NPT PORTS ABOVE 600# ANSI SHOWN SENSOR SIZE 1 3 900# & ABOVE STYLE HEAD LOW PRESSURE INSTRUMENT CONNECTION HIGH PRESSURE INSTRUMENT CONNECTION ID ODH FLOW ODP ODF WALL W FLO NOTICE FOR ACCURATE FLOW MEASUREMENT THE CORRECT HOLE SIZE IN PIPE MUST BE: 3/4 (19mm) INCH HIGH PRESSURE, REMOTE MOUNT HEAD OPTION 2500# OPPOSITE SIDE SUPPORT HI-PRESSURE REMOTE MOUNT WITH OPPOSITE SIDE SUPPORT DO NOT DRILL OVERSIZE DO NOT TORCH CUT HOLE (900# & ABOVE ANSI SHOWN) ® BOULDER, COLORADO SIZE A FSCM.NO. SCALE: NONE WT. DRAWING NO. 00485-1011 SHEET 5 OF 5