Transcript
! Important Safety Notice Please read this note carefully before using the product.
Warning • The module should be disconnected from the power supply before handling. • The power supply should be switched off before connecting or disconnecting the power or interface cables. • The module contains electronic components that generate high voltages (approx.65V) which may cause an electrical shock when touched. • Do not touch the electronic components of the module with any metal objects. • The VFD used on the module is made of glass and should be handled with care. When handling the VFD, it is recommended that cotton gloves be used. • The module is equipped with a circuit protection fuse. • Under no circumstances should the module be modified or repaired. Any unauthorized modifications or repairs will invalidate the product warranty. • The module should be abolished as the factory waste.
[Important Safety Notice]
GP1128A01A REV.A
1. FEATURES FUTABA GP1128A01A is a graphic display module using a FUTABA 160×64dots VFD. It consists of a control ASIC with internal Static-RAM of 2320bytes and power source. The module can be connected directly to the bus-line of the host system CPU. 2. GENERAL DESCRIPTION 2-1. DIMENSIONS, WEIGHT (Refer to FIGURE-4) Item Outer dimensions Weight
Specification (W) 125±1 (H) 56.3±1 (T) 29.6 MAX. Approx. 150
Table-1 Unit mm g
2-2. SPECIFICATIONS OF THE DISPLAY PANEL Item Display Area Number of Dots Dot Size (H×W) Dot Pitch (H×W) Color Illumination Luminance
Specification 71.9(W)×28.7(H) 160×64 0.35×0.35 0.45×0.45 Green (λp=505nm) 500 (Typ)
Table-2 Unit mm Dot mm mm − cd/m2
Note) By using a filter, uniform color range from blue to orange (including white) can be obtained.
2-3. ENVIRONMENT CONDITIONS Item Operation Temperature Storage Temperature Operating Humidity Storage Humidity Vibration (10 ∼ 55Hz) Shock
Symbol Topr Tstg Hopr Hstg − −
Min. -20 -30 20 20 − −
Max. +70 +80 85 90 4 40
Note) Avoid operations and or storage in moist environmental conditions.
[1/12]
Table-3 Unit °C °C % % G G
GP1128A01A REV.A
2-4. ABSOLUTE MAXIMUM RATINGS Item Supply Voltage Input Signal Voltage
Symbol Vcc VIS
Min. -0.3 -0.3
Max. 6.0 Vcc+0.3
Table-4 Unit Vdc V
2-5. RECOMMEND OPERATING CONDITIONS Item Supply Voltage H-Level Input Voltage L-Level Input Voltage
Symbol Vcc VIH VIL
Min. 4.5 2.6 −
Typ. 5.0 − −
Table-5 Unit Vdc V V
Max. 5.5 − 0.7
2-6. ELECTRICAL CHARACTERISTICS Item Supply Current (Note1) Power Consumption Luminance
Symbol Icc - L
H-Level Output Voltage
VOH
L-Level Output Voltage
VOL
Condition Vcc=5.0Vdc All on Vcc = 4.5Vdc IOH = -2mA Vcc = 4.5Vdc IOL = 3.2mA
Table-6 Max. Unit 1000 mA 5.0 W cd/m2 −
Min. − − 250
Typ. 750 3.75 500
3.6
−
−
V
−
−
0.5
V
Note) The surge current can be approx. 5 times the specified supply current at power on.
[2/12]
GP1128A01A REV.A
3. BASIC FUNCTION 3-1. Function Table 3-2. Function of Signal Lines 3-3. Command Table 3-4. Relationship of The Display Area to Address and Data 3-5. Function of Commands 3-1. Function Table Table-7 CS
WR
RD
L L L L
↑ ↑ H H
H H L L
C/ D H L H L
MODE Command Write-in Data Write-in - Data Read-out
3-2. Function of Signal Lines Table-8 Signal I/O Function D0~D7 I/O 8bit Data Bus I Write Signal WR I Read Signal RD I Chip Select Signal CS Command / Data Select Signal C/ D I C/ D ="H" : Command C/ D ="L" : Data Write and Data Read INT O Frame Signal (One output pulse per one display frame) Vcc - +5V - GND GND
[3/12]
GP1128A01A REV.A
3-3. Command Table The followings are all commands of this module. Command Setting Data Function (C/ D ="H") (C/ D ="L") 00H Screen 1 & Screen 2 are Displayed off ─ 01H Screen1 is Displayed on ─ 02H Screen2 is Displayed on ─ 03H Screen 1 & Screen 2 are Displayed on ─ 04H Read/Write address is automatically incremented ─ 05H Read/Write address is held ─ 08H D0~D7 Display data write-in 09H D0~D7 Display data read-out 0AH D0~D7 Setting lower address for Screen 1 started 0BH D0~D3 Setting upper address for Screen 1 started 0CH D0~D7 Setting lower address for Screen 2 started 0DH D0~D3 Setting upper address for Screen 2 started 0EH D0~D7 Setting lower address of Read/Write 0FH D0~D3 Setting upper address of Read/Write 10H OR display of Screen 1 & 2 ─ 11H EX-OR display of Screen 1 & 2 ─ 12H AND display of Screen 1 & 2 ─ 13H D0~D7 Brightness Adjustment 14H D0~D7 Internal function set Note) "─" in the above table is shown that the setting data is not needed.
[4/12]
Table-9 Default Select ○
○
00H 00H 00H 00H 00H 00H ○
FFH 00H
8-1
2 3 4
090F 090E 090D 090C 090B 090A 0909 0908
0007 0006 0005 0004 0003 0002 0001 0000
000F 000E 000D 000C 000B 000A 0009 0008
[5/12]
FIG. 2 Indicate the map at start address to set to 0900H
DATA
ADDRESS
08FF 08FE 08FD 08FC 08FB 08FA 08F9 08F8 290
08F7 08F6 08F5 08F4 08F3 08F2 08F1 08F0 289
08EF 08EE 08ED 08EC 08EB 08EA 08E9 08E8 288
04F7 04F6 04F5 04F4 04F3 04F2 04F1 04F0 161
04EF 04EE 04ED 04EC 04EB 04EA 04E9 04E8 160
04E7 04E6 04E5 04E4 04E3 04E2 04E1 04E0 159
04DF 04DE 04DD 04DC 04DB 04DA 04D9 04D8 158
1
0907 0906 0905 0904 0903 0902 0901 0900
D0-D7 D0-D7 D0-D7 D0-D7 D0-D7 D0-D7 D0-D7 D0-D7
64-57 56-49 48-41 40-33 32-25 24-17 16-9
8-1
2 3
000F 000E 000D 000C 000B 000A 0009 0008 0017 0016 0015 0014 0013 0012 0011 0010
159 160 161
288 289 290
04F7 04F6 04F5 04F4 04F3 04F2 04F1 04F0 04FF 04FE 04FD 04FC 04FB 04FA 04F9 04F8 0507 0506 0505 0504 0503 0502 0501 0500
08FF 08FE 08FD 08FC 08FB 08FA 08F9 08F8 0907 0906 0905 0904 0903 0902 0901 0900 090F 090E 090D 090C 090B 090A 0909 0908
04EF 04EE 04ED 04EC 04EB 04EA 04E9 04E8 158
1
0007 0006 0005 0004 0003 0002 0001 0000
D0-D7 D0-D7 D0-D7 D0-D7 D0-D7 D0-D7 D0-D7 D0-D7
64-57 56-49 48-41 40-33 32-25 24-17 16-9
GP1128A01A REV.A
3-4. Relationship of The Display Area to Address and Data The following map is shown in case of 0000H on display start address. The actual display area is the part of enclosing with the solid line of FIG.1 and FIG.2. FIG.1 & FIG.3 indicate the map at start address to set to 0000H.
FIG.1 Position of display dot to address and data
D7
D6
D5
D4
D3
D2
D1
D0 0 0 0 0 H 0 0 0 8 H 0 0 1 0 H 0 0 1 8 H 0 0 2 0 H
1 F H
2 4 H
4 4 H
2 4 H
1 F H
0 0 2 8 H 0 0 3 0 H
FIG.3 Data Write-in 0 0 3 8 H
GP1128A01A REV.A
3-5. Function of Commands 3-5-1. Screen Display on / off Control (00H, 01H, 02H, 03H) The latest command becomes effective. At power on, screen 1 and 2 are set to Display off mode. Therefore, the Display on mode command should be written in, after display pattern data input. In case of executing Display on mode before display data input at initial, random pattern may be displayed. 3-5-2. Setting of Write Address Mode (04H, 05H) These commands select either the write or read address is incremented by single step automatically or is held after data write and data read. When a memory address is set to 090FH, next memory address is set to 0000H. 3-5-3. Data Write (08H) After executing the Write address setting command, this command shall be executed. The following indicate the display data 55H, AAH and 01H write-in. C/ D
CS
WR DATA ADDRESS
08H
-
55H
AAH
n
n+1
01H
n+2
3-5-4. Data Read (09H) After executing the Read address setting command, this command shall be executed. Dummy read is necessary. The correct data can be read from the second byte. The following indicate the display data read out. C/ D CS
WR RD
DATA ADDRESS
09H
Dummy
Valid
Valid
-
n
n
n+1
[6/12]
GP1128A01A REV.A
3-5-5. Setting of Display Start Address (0AH, 0BH, 0CH, 0DH) The display start address is just pointed to the left and top line of the display area. Screen 1 and 2 can be independently set the display start address each other. This address is divided to the two portions with upper (five bits) and lower (eight bits) address, and lower address shall be set first, then set the upper address. The smooth scroll of displaying can be achieved by synchronizing with the change of display address by the INT signal at every frame. The following indicate the display start address of screen1 to set to 023EH. C/ D CS
WR DATA
0AH
3EH
0BH
02H
3-5-6. Setting of Write/Read Address (0EH, 0FH) This command is set the write/read address of displaying data. This address is divided the two portions with upper (five bits) and lower (eight bits) address, and lower address shall be set first, then set the upper address. Only the upper address is available to be changed independently. When the lower address is changed, it is required to change the both address. 3-5-7. Screen OR / EX-OR / AND Display Select (10H、11H、12H) The latest command becomes effective. 3-5-8. Luminance Adjustment (13H) Write-in data (00H~50H) allows luminance to be adjusted. When the module is turned on, it is set to dimming level 0%.
Input Data 00H 0AH 14H 1EH 28H 32H 3CH 46H 50H 64~FFH
Table-10 Luminance 100% (Max.) 90% 80% 70% 60% 50% 40% 30% 20% 0% (Display blank)
Note1) Write-in data (64H~FFH)allows luminance to be 0%. Note2) Write-in data is available from 00H to 50H. Note3) Write-in data (51H~63H) prohibits.
[7/12]
GP1128A01A REV.A
3-5-9. Internal Function Set (14H) When the module is turned on, it has to be written 20H after this command data (14H) is sent to a module. Note) Do not write an other data instead of 20H.
4. INTERFACE CONNECTION
Pin No. 1 3 5 7 9 11 13 15 17 19
Description D0 D2 D4 D6 GND WR CS Vcc Vcc GND
Pin No. 2 4 6 8 10 12 14 16 18 20
[8/12]
Table-11 Description D1 D3 D5 D7 INT RD C/ D Vcc GND N.C
GP1128A01A REV.A
5. TIMING CHART 5-1. Write-in timing
C/D Min.40nS
Min.10nS
CS Min.40nS
Min.60nS
Min.10nS
WR Min.60nS
Min.10nS
DATA 1) The time of each one byte access is neccessary with 1us min.
5-2. Read-out timing C/D Min.40nS
Min.10nS
Min.40nS
Min.10nS
CS
RD Max.50nS
Min.0nS
DATA 1) The time of each one byte access is neccessary with 1us min.
5-3. INT timing The module generates 80usec of INT signal at every 6.56msec of refresh timing. Display start address should be executed during period of INT="H" for smooth scroll. 80uS. INT 6.56mS.
[9/12]
GP1128A01A REV.A
6. OUTER DIMENSION FIGURE-4
[10/12]
8
~
[11/12]
GND
+5.0V
D7
D0
C/D
DC/DC CONVERTER
Internal Static-RAM 2320bytes
INT
CS
CONTROL ASIC
WR
RD
Ef
VH
GRID CONTROL
ANODE CONTROL
OSC
GP1128A01A REV.A
7. CIRCUIT BLOCK DIAGRAM FIGURE-5
160 x 64 DOTS GRAPHIC DISPLAY
GP1128A01A REV.A
8. CAUTIONS FOR OPERATION 8-1. Applying lower voltage than the specified may cause non activation for selected pixels. Conversely, higher voltage may cause non-selected pixel to be activated. If such a phenomenon is observed, check the voltage level of the power supply. 8-2. The DC/DC converter generates approximately 65Vdc, avoid touching it with bare hands, or to other circuits. 8-3. Avoid using the module where excessive noise interface is expected. Noise affects the interface signal and causes improper operation. Keep the length of the interface cable less than 30cm. (When the longer cable is required, please confirm there is no noise affection.) 8-4. When power is turned off, the capacitor will not discharge immediately. Avoid touching IC and others. The shorting of the mounted components within 30 sec., after power off, may cause damage. 8-5. When fixed pattern is displayed for a long time, you may see uneven luminance. It is recommended to change the display patterns sometimes in order to keep best display quality. 8-6. DC/DC converter is equipped on the module, the surge current may be approximately 5 times the specified supply current at the power on.
[12/12]