Preview only show first 10 pages with watermark. For full document please download

Manual 11524141

   EMBED


Share

Transcript

© COPYRIGHT 2010 BY INDUSTRIAL FIBER OPTICS, INC. ALL RIGHTS RESERVED. REVISIONS STRIP LENGTH 2.00 .079" ECO DESCRIPTION REV DATE DWN APVD A Initial Release 6/9/2010 BB AR B Added thru hole diameter tolerance 4/15/2014 BB AR 25.0 .98" 38.0 1.50" Ø.57 Ø.50 9.2 .36" Ø.0224" Ø.0197" NOTES: 1. SUITABLE FOR .5mm POF WITH 1mm OR 2.2mm JACKET INSTRUCTIONS FOR SH2001: 1. STRIP 2mm OF JACKET FROM FIBER. 2. SLIP BOOT OVER CABLE JACKET. 3. APPLY EPOXY TO BARE FIBER AND INSERT INTO FERRULE; ROTATE FIBER DURING INSERTION TO EVENLY DISTRIBUTE EPOXY. 4. SLIP BOOT DOWN OVER CONNECTOR. POLISH AFTER EPOXY HAS CURED FULLY. 8.0 .31" 53.4 2.10" RECOMMENDED EPOXY: EPO-TEK 301 CRIMP TOOL FOR 2.2mm JACKETED CABLE: IF 370046 USE 2.5 [.10"] HEX CRIMP UNLESS OTHERWISE SPECIFIED DIMENSIONS MILLIMETERS [IN.] TOLERANCES 0 PLC: ± 1 1 PLC: ± .25 2 PLC: ± .127 3 PLC: ± .025 4 PLC: ± .013 ANGLE: ± 1/2° METRIC SURFACE 0.8 TEXTURE: REMOVE BURRS AND SHARP EDGES FLATNESS .005mm PER mm ALL DIMENSIONS AFTER FINISH PRODUCT MATERIAL FINISH DRAWN BY DATE CHECKED BY DATE 51 0072 Industrial Fiber Optics TEMPE, AZ 85281 Stainless Steel NAME Passivated 500µm SMA B. Bidwell 6/9/2010 A. Reyes 6/9/2010 SIZE A SCALE 1:1 PART NUMBER REV B 51 0072 DO NOT SCALE DRAWING Sheet 1 of 1