Transcript
© COPYRIGHT 2010 BY INDUSTRIAL FIBER OPTICS, INC. ALL RIGHTS RESERVED.
REVISIONS
STRIP LENGTH 2.00 .079"
ECO
DESCRIPTION
REV
DATE
DWN
APVD
A
Initial Release
6/9/2010
BB
AR
B
Added thru hole diameter tolerance
4/15/2014
BB
AR
25.0 .98"
38.0 1.50"
Ø.57 Ø.50
9.2 .36"
Ø.0224" Ø.0197"
NOTES: 1. SUITABLE FOR .5mm POF WITH 1mm OR 2.2mm JACKET INSTRUCTIONS FOR SH2001: 1. STRIP 2mm OF JACKET FROM FIBER. 2. SLIP BOOT OVER CABLE JACKET. 3. APPLY EPOXY TO BARE FIBER AND INSERT INTO FERRULE; ROTATE FIBER DURING INSERTION TO EVENLY DISTRIBUTE EPOXY. 4. SLIP BOOT DOWN OVER CONNECTOR. POLISH AFTER EPOXY HAS CURED FULLY.
8.0 .31"
53.4 2.10" RECOMMENDED EPOXY: EPO-TEK 301 CRIMP TOOL FOR 2.2mm JACKETED CABLE: IF 370046 USE 2.5 [.10"] HEX CRIMP UNLESS OTHERWISE SPECIFIED DIMENSIONS
MILLIMETERS [IN.]
TOLERANCES
0 PLC: ± 1 1 PLC: ± .25 2 PLC: ± .127 3 PLC: ± .025 4 PLC: ± .013 ANGLE: ± 1/2°
METRIC
SURFACE 0.8 TEXTURE:
REMOVE BURRS AND SHARP EDGES FLATNESS .005mm PER mm ALL DIMENSIONS AFTER FINISH
PRODUCT MATERIAL FINISH DRAWN BY DATE CHECKED BY DATE
51 0072
Industrial Fiber Optics TEMPE, AZ 85281
Stainless Steel NAME
Passivated
500µm SMA
B. Bidwell 6/9/2010 A. Reyes 6/9/2010
SIZE
A
SCALE
1:1
PART NUMBER
REV
B
51 0072
DO NOT SCALE DRAWING
Sheet 1 of 1