Preview only show first 10 pages with watermark. For full document please download

Manual 11648688

   EMBED


Share

Transcript

150W DC-AC Inverter Pure Sine Wave Model S150-112 12 VDC-110 VAC S150-124 24 VDC-110 VAC Design Features -- Pure sine wave output (THD < 6%) -- Switch selectable output frequency: 50 / 60 Hz -- Remote on/off control using external mechanical / transistor switch -- Input and output are fully isolated -- Advanced micro-controller -- Load controlled cooling fans save power consumption -- Tri-color LED for display of operational status and fault indications -- Protections: overload, short-circuit, leakage, low and high DC input voltages, high temperature and reverse polarity -- Safety: Listed to UL Standard UL-458 -- EMC: Complies with FCC Part 15(B), Class B 2 YEAR WARRANTY Model No. OUTPUT INPUT OUTPUT VOLTAGE OUTPUT FREQUENCY TYPE OF OUTPUT WAVEFORM TOTAL HARMONIC DISTORTION OF OUTPUT WAVEFORM CONTINUOUS OUTPUT POWER (At Power Factor = 1) SURGE OUTPUT POWER (At Power Factor = 1) PEAK EFFICIENCY (At full load) AC OUTPUT CONNECTIONS NOMINAL DC INPUT VOLTAGE DC INPUT VOLTAGE RANGE DC INPUT CURRENT AT NO LOAD S150-112 110 VAC, +/- 5% 50 / 60 Hz +/- 0.3% (Selected by Switch) Pure Sine Wave < 6% 150 W 150 W 200 W 200 W 87% 88% Dual NEMA5-15R receptacles with GFCI protection 12 VDC 24 VDC 10.5 to 15 VDC 21 to 30 VDC 0.3 A 0.35 A Detachable pair of wires with Anderson Power Pole Connectors on inverter side DC INPUT CONNECTIONS DISPLAY REMOTE OPERATION COOLING COMPLIANCE ENVIRONMENT DIMENSIONS WEIGHT STATUS OF OPERATIONS & PROTECTIONS WIRED ON/OFF CONTROL LOW DC INPUT VOLTAGE SHUTDOWN HIGH DC INPUT VOLTAGE SHUTDOWN SHORT CIRCUIT SHUTDOWN OVERLOAD SHUTDOWN GROUND FAULT SHUTDOWN OVER TEMPERATURE SHUTDOWN REVERSE POLARITY ON DC INPUT SIDE FORCED AIR COOLING SAFETY EMI / EMC OPERATING TEMPERATURE RANGE STORAGE TEMPERATURE RANGE (L X W X H), MM (L X W X H), INCHES KG LBS S150-124 By steady / flashing patterns of 3 - color LED By external contact closure through mechanical / transistor switch 10.5 VDC 15.3 VDC 21.0 VDC 30.6 VDC Yes Yes GFCI protected dual NEMA5-20R receptacles Yes Yes. Internal fuses will blow Thermostatically controlled fan UL listed to UL-458 Meets FCC Part 15(B), Class A 0 oC to + 40 oC - 30 oC to 70 oC 200 x 132 x 72 7.9 x 5.2 x 2.8 2.7 5.6 NOTE: Specifications are subject to change without notice To view a full selection of Samlex products visit our website at www.samlexamerica.com or contact us: 1(800) 561-5885 or [email protected]