Preview only show first 10 pages with watermark. For full document please download

Manual 12211094

   EMBED


Share

Transcript

EZH2O® Bottle Filling Station Versatile Bi-Level EZ Cooler Models EZSTL8WS & EZSTLDDWS SPECIFICATIONS RATED FOR INDOOR USE ONLY PRODUCT SPECIFICATION Unit shall include electric water cooler with bottle filling station. EZSTL8WS shall deliver 8 GPH of 50°F drinking water at 90°F ambient and 80°F inlet water. EZSTLDDWS shall deliver non-chilled drinking water. Cooler units shall have pushbar activation. Bottle filling unit shall include an electronic sensor for touchless activation with auto 20-second shut-off timer. Shall include Green Ticker™ displaying count of plastic bottles saved from waste. Bottle filler shall provide 1.1-1.5 gpm flow rate with laminar flow to minimize splashing. Shall include integrated silver ion anti-microbial protection in key areas. Unit shall meet ADA guidelines. Unit shall be lead-free design which is certified to NSF/ANSI 61 and 372 and meets Federal and State low-lead requirements. Unit shall be certified to UL399 and CAN/CSA 22.2 No. 120. STANDARD FEATURES *Versatile cooler configuration as shipped • • • • • • • Sanitary, touchless activation with auto 20-second shut-off (Bottle Filler) Easy-Touch front and side pushbar controls (Cooler) Integrated Silver Ion Anti-microbial Protection in key areas Quick Fill Rate: 1.1 gpm (EZSTL8WS); 1.5 gpm (EZSTLDDWS) Laminar Flow provides minimal splash Real Drain System eliminates standing water Visual User Interface display includes: • Innovative Green Ticker™ counts bottles saved from waste • Available with Flexi-Guard® bubbler or Vandal-resistantt bubbler (tincludes “VR” code in model no. see chart below) • Versatile cooler design allows units to be installed either left-hand high and right-hand low or left-low and right high • Cooler panel finishes: Light Gray Granite Vinyl Clad Steel or Stainless Steel *Versatile cooler configuration alternate installation CONSTRUCTION • • • • • • COOLING SYSTEM (Models EZSTL8WS & EZSTL8WSVR only) • • • • • Compressor: hermetically-sealed, reciprocating type, single phase. Sealed-in lifetime lubrication. Condenser: Fan cooled, copper tube with aluminum fins. Fan motor is permanently lubricated. Cooling Unit: Combination tube-tank type. Self-cleansing. Continuous copper tubing with stainless steel tank. Fully insulated with EPS foam which meets UL requirements for self-extinguishing material. Refrigerant Control: Refrigerant R134a is controlled by accurately calibrated capillary tube. Temperature Control: Easily accessible enclosed adjustable thermostat is factory preset. Requires no adjustment other than for altitude requirements. Stainless Steel basin with integral drain Galvanized structural steel cooler chassis provides structural integrity Stainless steel bottle filler wrapper with ABS plastic alcove Cooler cabinet available as Light Gray Granite Vinyl Clad Steel or Stainless Steel (additional cost) construction Flexi-Guard® Safety Bubbler (option) utilizes an infused anti-microbial pliable polyester elastomer to prevent accidental mouth injuries. Flexes on impact. Vandal-resistantt bubbler (option) is one-piece heavy-duty Warranty: 5 year limited warranty on the unit’s refrigeration system. Electrical components and water system are warranted for 12 months from date of installation or 18 months from factory shipment, whichever date falls first. CAPACITIES CHART Voltage / Hertz Chilling** Capacity F.L. Amps Rated Watts Approx. Ship Wt. UL399 and CAN/ CSA 22.2 No. 120 Certified ADA COMPLIANT ANSI/NSF 61 and 372 Certified GreenSpec® Listed EZSTL8WS(VR)*K 115V / 60Hz 8 GPH 5.0 370 101 lbs • • • • EZSTL8WS(VR)*2K 220V / 50Hz 6.7 GPH 2.5 370 101 lbs ++ • • • EZSTL8WS(VR)*3K 220V / 60Hz 8 GPH 2.5 370 101 lbs ++ • • • EZSTLDDWS(VR)*K 115V/60 Hz – 1.0 15 91 lbs • • • • EZSTLDDWS(VR)*2K 220V/50Hz – 0.5 15 91 lbs ++ • • • EZSTLDDWS(VR)*3K 220V/60Hz – 0.5 15 91 lbs ++ • • • Model *Color code of (L) Light Gray Granite or (S) Stainless Steel cooler panels. **Based on 80°F inlet water & 90°F ambient air temp for 50°F chilled drinking water. ++Complies; not third party certified. In keeping with our policy of continuing product improvement, Elkay reserves the right to change specification without notice. Please visit elkay.com for the most current version. This specification describes an Elkay product with design, quality and functional benefits to the user. When making a comparison of other producer’s offerings, be certain these features are not overlooked. 2222 Camden Court Oak Brook, IL 60523 630-572-3192 elkay.com © 2014 Elkay SPEC14-72 (06/2014) EZH2O® Bottle Filling Station Versatile Bi-Level EZ Cooler Models EZSTL8WS & EZSTLDDWS IMPORTANT! INSTALLER PLEASE NOTE: These units are designed and built to provide water to the user which has not been altered by materials in the cooler waterway. The grounding of electrical equipment such as telephone, computers, etc. to water lines is a common procedure. This grounding may be in the building but may also occur away from the building. This grounding can cause electrical feedback into a water cooler creating an electrolysis which results in a metallic taste or an increase in the metal content of the water. This condition is avoidable by installing the cooler using the proper materials as shown. ROUGH-IN DIMENSIONS RATED FOR INDOOR USE ONLY NOTICE This water cooler must be connected to the water supply using a dielectric coupling. The cooler is furnished with a non- metallic strainer which meets this requirement. The drain trap which is provided by the installer should also be plastic to completely isolate the cooler from the building plumbing system. Bottle Filler unit will mount on bracket attached to wall by 6 holes (as shown). Water and electrical will connect through pre-punched hole in basin. Model shown with Flexi-Guard® bubbler. ROUGH-IN FOR LEFT-HAND HIGH SIDE MODELS 17 7/8" 454mm 7" 178mm ‰ 19" 483mm 7/16" X 3/4" 11mm X 19mm OBROUND HOLES (6) 7" 178mm 3 9/16" 90mm 18 3/8" 467mm 9/32" Ø 7mm Ø HOLES 12 2" 51mm 6 3/8" 162mm 6 3/8" 162mm 6 3/8" 162mm 6 3/8" 162mm ‰ 18 7/8" 479mm HANGER BRACKET 15" 381mm 2 7/8" 73mm A (ALT. LOCATION) 51 9/16" 1310mm 2" 51mm 2" 51mm 7/8" 22mm E B A PREFERRED LOCATION 38 3/8" 975mm ORIFICE HEIGHT 36 13/16" 936mm RIM HEIGHT E 8 1/16" 205mm F 34 5/16" 872mm D PREFERRED 24 1/2" LOCATION 622mm 22 15/16" 583mm 19 7/16" 494mm D (ALT. LOCATION) 17 7/16" 443mm 28 13/16" 732mm 2" 51mm 13 15/16" 354mm 3 7/8" 98mm 5 3/4" 146mm 7" 178mm 21 7/8" F 19" 556mm 483mm 7" 178mm 32 7/8" 835mm ORIFICE HEIGHT C 31 5/16" 796mm RIM HEIGHT 27" 686mm ADA REQUIREMENT 12 1/2" 318mm 1 7/16" 37mm 3" 77mm FINISHED FLOOR REDUCE HEIGHT BY 3 INCHES FOR INSTALLATION OF CHILDRENS ADA COOLER LEGEND: A = Recommended Water Supply location. Shut-off Valve (not furnished) to accept 3/8” O.D. unplated copper tube. Up to 3” (76mm) maximum out from wall. B = Recommended Waste Outlet location. To accommodate 1-1/2” nominal drain. Drain stub 2” (51mm) out from wall. C = 1-1/2” Trap (not furnished). D = Electrical Supply (3) Wire Recessed Box Duplex Outlet. E = Insure proper ventilation by maintaining 6” (152mm) minimum clearance from cabinet louvers to wall. F = 7/16” (11mm) Bolt Holes for fastening to wall. NOTE: Installations Must Use Ground Fault Circuit Interrupter (GFCI). Page 2 2222 Camden Court Oak Brook, IL 60523 630-572-3192 elkay.com Job Name: ____________________________________ Model: _______________________ Qty. ____________ Contact: ______________________________________ Approval Signature: _____________________________ Notes: Printed in U.S.A. © 2014 Elkay EZH2O® Bottle Filling Station Versatile Bi-Level EZ Cooler Models EZSTL8WS & EZSTLDDWS ROUGH-IN DIMENSIONS RATED FOR INDOOR USE ONLY NOTICE This water cooler must be connected to the water supply using a dielectric coupling. The cooler is furnished with a non- metallic strainer which meets this requirement. The drain trap which is provided by the installer should also be plastic to completely isolate the cooler from the building plumbing system. IMPORTANT! INSTALLER PLEASE NOTE: These units are designed and built to provide water to the user which has not been altered by materials in the cooler waterway. The grounding of electrical equipment such as telephone, computers, etc. to water lines is a common procedure. This grounding may be in the building but may also occur away from the building. This grounding can cause electrical feedback into a water cooler creating an electrolysis which results in a metallic taste or an increase in the metal content of the water. This condition is avoidable by installing the cooler using the proper materials as shown. Bottle Filler unit will mount on bracket attached to wall by 6 holes (as shown). Water and electrical will connect through pre-punched hole in basin. Model shown with Flexi-Guard® bubbler. ROUGH-IN FOR RIGHT-HAND HIGH SIDE MODELS 17 7/8" 454mm 7/16" X 3/4" 11mm X 19mm OBROUND HOLES (6) 7" 178mm ‰ 19" 483mm 7" 178mm 3 9/16" 90mm 18 3/8" 467mm 18 7/8" 479mm 6 3/8" 162mm 6 3/8" 162mm 15" 381mm 6 3/8" 162mm 9/32" Ø 7mm Ø HOLES 12 6 3/8" 162mm HANGER BRACKET 2" 51mm 2 7/8" 73mm ‰ 2" 51mm A PREFERRED LOCATION E 51 9/16" 1310mm 2" 51mm 7/8" 22mm E B 36 13/16" 936mm RIM HEIGHT 28 13/16" 732mm 2" 51mm F 21 7/8" 556mm 19" 483mm 17 7/16" 443mm 13 15/16" 354mm 3 7/8" 98mm A (ALT. LOCATION) D PREFERRED LOCATION 38 3/8" 975mm ORIFICE HEIGHT 34 5/16" 872mm F 24 1/2" 622mm 5 3/4" 146mm 7" 178mm 7" 178mm 22 15/16" 583mm 19 7/16" 494mm D (ALT. LOCATION) 8 1/16" 205mm 32 7/8" 835mm ORIFICE HEIGHT C 31 5/16" 796mm RIM HEIGHT 27" 686mm ADA REQUIREMENT 1 7/16" 37mm 12 1/2" 318mm 3" 76mm FINISHED FLOOR REDUCE HEIGHT BY 3 INCHES FOR INSTALLATION OF CHILDRENS ADA COOLER LEGEND: A = Recommended Water Supply location. Shut-off Valve (not furnished) to accept 3/8” O.D. unplated copper tube. Up to 3” (76mm) maximum out from wall. B = Recommended Waste Outlet location. To accommodate 1-1/2” nominal drain. Drain stub 2” (51mm) out from wall. C = 1-1/2” Trap (not furnished). D = Electrical Supply (3) Wire Recessed Box Duplex Outlet. E = Insure proper ventilation by maintaining 6” (152mm) minimum clearance from cabinet louvers to wall. F = 7/16” (11mm) Bolt Holes for fastening to wall. NOTE: Installations Must Use Ground Fault Circuit Interrupter (GFCI). Page 3 Job Name: ____________________________________ Model: _______________________ Qty. ____________ Contact: ______________________________________ Approval Signature: _____________________________ Notes: 2222 Camden Court Oak Brook, IL 60523 630-572-3192 elkay.com Printed in U.S.A. © 2014 Elkay