Preview only show first 10 pages with watermark. For full document please download

Manual 13028399

   EMBED


Share

Transcript

TYPICAL ECOSYSTEM LOOP DETAIL INPUT FEED TO 0-10VLED DRIVER (BY OTHERS) INPUT FEED FROM DISTRIBUTION PANEL INPUT FEED FROM DISTRIBUTION PANEL INPUT FEED FROM DISTRIBUTION PANEL H3D Txxx x x x xx EC5 Txxxx J UNV x IR OCC +20 Daylight DH SH NEU N/C HOT E1 E2 E1 E2 NEU DH SH E1 E2 HI-LUME 3D BALLAST ECOSYSTEM BALLAST TYPICAL ECOSYSTEM LOOP 62 BALLASTS/INTERFACES MAX Input Feed from Distribution Panel EHD Txxx x x x xx NEU E1 E2 Common NEU DH SH HI-LUME LED INPUT FEED FROM DISTRIBUTION PANEL H-SERIES BALLAST EcoSystem Compact Fluorescent Ballast INPUT FEED FROM DISTRIBUTION PANEL TVI-LMF-2A ECOSYSTEM TO 0-10V INTERFACE DIMENSIONS: 107mm[4.2"] (W) X 76mm[3.0"] (H) X 25,4mm[1.0"](D) LDE5xE1CRN-xxxxx LUTRON LED DRIVER 220-240V CE RATED LED 5 SERIES DRIVER TO ECOSYSTEM BALLASTS/MODULES (64 MAX PER LOOP) ECOSYSTEM DIGITAL LOOP # UP TO 10 WIRELESS (OF EACH TYPE) PER QSM TO NORMAL 3PHASE 4WIRE DISTRIBUTION PANEL CONTRACTOR TO PROVIDE (1) 3P BREAKER. LUTRON PK-3BRL-MAW-LO1 868 MHZ PICO WIRELESS 3 BUTTON CONTROL WITH RAISE/LOWER TRA CERTIFIED, CE MARKED W/ RANIA SQ WALLPLATE LRF3-OCRB-P-WH 868MHZ WIRELESS OCCUPANCY/VACANCY SENSOR 102mm[4.0"] (DIA) X 33mm[1.3"] (D) MAX 10 PER QSM *DEVICE IS SURFACE-MOUNTED AND BATTERY POWERED, DOES NOT REQUIRE POWER FEED PFP-1-B-FAW-M PICO DIMENSIONS: 66mm[2.6"] (H) X 33mm[1.3"] (W) X 8mm[0.31"] (D) W/WALLPLATE: 86mm[3.39"] (H) X 86mm[3.39"] (W) X 9,4mm[0.37"] (D) *SEE SPECIFICATION SHEET FOR MOUNTING INSTRUCTIONS LOCATION TBD LRF3-DCRB-WH 868MHZ WIRELESS DAYLIGHT SENSOR 41mm[1.6"] (DIA) X 17mm[0.7"] (D) MAX 10 PER QSM *DEVICE IS SURFACE-MOUNTED AND BATTERY POWERED, DOES NOT REQUIRE POWER FEED LOCATION TBD LOCATION TBD (OPTION:WITH L-CRMK-WH RECESS MOUNT KIT FOR NON-METALLIC CEILINGS) 5 #12AWG ZONE X Red Red INPUT POWER (230 VAC) PP-230H POWER SUPPLY 59mm[2.33"] (H) X 93,7mm[3.69"] (W) X 34,5mm[1.36"] (D) LUT-ELI-3PH EMERGENCY LIGHTING INTERFACE 197mm[7.75"] (H) X 102mm[4"] (W) X 63,5mm[2.5"] (D) ZONE X ZONE X ECOSYSTEM DIGITAL LOOP # ECOSYSTEM DIGITAL LOOP # ZONE X ZONE X TO ECOSYSTEM BALLASTS/MODULES (64 MAX PER LOOP) ZONE X ZONE X ZONE X TO ECOSYSTEM BALLASTS/MODULES (64 MAX PER LOOP) ZONE X ZONE X TYPICAL WALL CONTROL (OTHER CONFIGURATIONS AVAILABLE) 100V-240V DEDICATED NORMAL/EMERGENCY INPUT FEED CORPORATE WIRELESS NETWORK (BY OTHERS) LINK: A (CONFIGURABLE LINK) E 220-240 V CONTROL POWER INPUT QSM3-4W-C QUANTUM SENSOR MODULE (QSM) WITH (4) UNIVERSAL WIRED INPUTS AND 868MHZ WIRELESS RECEIVER 18.29m[60'] RADIUS RF COVERAGE (9.14m[30'] THROUGH WALLS) 102.6mm[4.04"] (DIA) X 29.7mm[1.17"] (D) LOCATION TBD E E Q Q 220-240 V CONTROL POWER INPUT 220-240 V CONTROL POWER INPUT Q Q QSWSE-5BRLN-WH 5-BUTTON SCENE SELECT WITH RAISE/LOWER REQUIRES EBB-1-SQ(RD) WALLBOX CONTROL DIMENSIONS: 86mm[3.375"] (H) X 86mm[3.375"] (W) X 6mm[0.25"] (D) WALLBOX DIMENSIONS: SQ: 71mm[2.81"] (H) X 71mm[2.81"] (W) X 47mm[1.87"] (D) RD:71mm[2.81"] (DIA.) X 61mm[2.375"] (D) LOCATION TBD QP3-1PL-100-240 QUANTUM LIGHT MANAGEMENT HUB CONTAINING (1) QUANTUM PROCESSOR WITH (2) CONFIGURABLE LINKS ENCLOSURE DIMENSIONS: 286mm[11.25"] (H) X 191mm[7.50"]) (W) X 80mm[3.16"] (D) INSTALLING CONTRACTOR TO COORDINATE ALL NETWORK CONNECTIONS AND COMMUNICATION REQUIREMENTS WITH IT CONTRACTOR AND OWNER (LUTRON Q-CONTROL+ APPLICATION AVAILABLE FOR CLIENT DOWNLOAD) ZONE X LUTRON Q LINK: B (CONFIGURABLE LINK) TO NETWORK (QS-EO OR QS-LO) ZONE X QSNE-4S10-D INTERNATIONAL ENERGI SAVR NODE w/ (4) SWITCH OUTPUTS DIN RAIL MOUNTED 89,7mm[3.5"] (H) X 161,7mm [6.38"] (W) X 60,6mm[2.38"] (D) LOCATION TBD QSNE-2ECO-D INTERNATIONAL ENERGI SAVR NODE w/ (2) ECOSYSTEM DIGITAL LINKS DIN RAIL MOUNTED 89,7mm[3.5"] (H) X 161,7mm [6.38"] (W) X 60,6mm[2.38"] (D) LOCATION TBD Q QSNE-4T10-D INTERNATIONAL ENERGI SAVR NODE w/ (4) 0-10V / SWITCH OUTPUTS DIN RAIL MOUNTED 89,7mm[3.5"] (H) X 161,7mm [6.38"] (W) X 60,6mm[2.38"] (D) LOCATION TBD QSNE-4A-D INTERNATIONAL ENERGI SAVR NODE w/ (4) PHASE-ADAPTIVE OUTPUTS CE RATED DIN RAIL MOUNTED 90mm[3.55"] (H) X 216mm[8.5"] (W) X 76mm[3"] (D) LOCATION TBD TO ADDITIONAL QS DEVICES (MAX OF 99 DEVICES / QS LINK) LOCATION TBD ALTERNATIVE OCCUPANCY/VACANCY SENSORS FOR SPECIFIC APPLICATIONS OPTIONAL IPAD CONTROL REFER TO LOAD SCHEDULE SHEET FOR FEEDER INFORMATION REFER TO LOAD SCHEDULE SHEET FOR FEEDER INFORMATION REFER TO LOAD SCHEDULE SHEET FOR FEEDER INFORMATION QS-LO: QUANTUM LOCAL AREA NETWORK LUTRON ONLY. THE QUANTUM INTER-PROCESSOR AND SERVER NETWORK IS A DEDICATED LAN FOR THE LUTRON SYSTEM. THE QUANTUM SERVER OR PC AND ALL NODES ON THE LAN ARE LIMITED TO LUTRON QUANTUM PROCESSOR AND LUTRON QUANTUM SERVER OR PC. ALL NETWORK EQUIPMENT INCLUDING ROUTERS, SWITCHES, AND NETWORK CABLES ARE SUPPLIED BY OTHERS TO LUTRON SPECIFICATIONS. APPLE IPAD (BY OTHERS) W/ LUTRON Q-CONTROL + APPLICATION (AVAILABLE FOR CLIENT DOWNLOAD FOR FREE AT ITUNES) REQUIRES MOBILE CONTROL AND PROGRAMMING SOFTWARE LICENSE (QSW-MC-PS-A) (1) LICENSE REQUIRED PER IPAD P E CONTROL FEED REFER TO CONTROL CKT. NOTE Softswitch P X XP SOFTSWITCH PANEL DIMENSIONS: 1499mm[59"] (H) X 406mm[16"] (W) X 102mm[4"] (D) LOCATION TBD TO BACNET BUILDING MANAGEMENT NETWORK (BY OTHERS) DEDICATED ETHERNET ENVIRONMENT REFER TO LOAD SCHEDULE SHEET FOR FEEDER INFORMATION P X GP DIMMER PANEL DIMENSIONS: 940mm[37"] (H) X 711mm[28"] (W) X 305mm[12"] (D) LOCATION TBD P X LP DIMMER PANEL DIMENSIONS: 1499mm[59"] (H) X 381mm[15"] (W) X 102mm[4"] (D) LOCATION TBD P TO ADDITIONAL QUANTUM PANELS (MAX OF 32 PANELS / PANEL LINK) X CCP DIMMER PANEL DIMENSIONS: 1499mm[59"] (H) X 381mm[15"] (W) X 102mm[4"] (D) LOCATION TBD LOCATION TBD (OPTION:WITH L-CRMK-WH RECESS MOUNT KIT FOR NON-METALLIC CEILINGS) LRF3-OKLB-P-WH 868MHZ WIRELESS CORNER MOUNTED OCCUPANCY/VACANCY SENSOR 110mm[4.35"] (H) X 46mm[1.8"] (W) X 34mm[1.35"] (D) MAX 10 PER QSM *DEVICE IS SURFACE-MOUNTED AND BATTERY POWERED, DOES NOT REQUIRE POWER FEED LOCATION TBD CONTROL CIRCUIT NOTE: SUPPLIES POWER FOR INTERNAL OPERATION. LUTRON RECOMMENDS A DEDICATED 120V OR 277V, 20A 1 PHASE 2 WIRE FEED TO POWER THE CONTROL CIRCUIT IN THE PANEL. IF THE CONTROL CIRCUIT IS TAPPED FROM A CIRCUIT THAT POWERS A RELAY IN THE PANEL, IT DRAWS A MAXIMUM OF 1.5A TOWARD THE TOTAL LOAD FOR THAT CIRCUIT. LRF3-OHLB-P-WH LRF3-DCRB-WH 868MHZ WIRELESS 868MHZ WIRELESS HALLWAY MOUNTED DAYLIGHT SENSOR OCCUPANCY/VACANCY SENSOR 41mm[1.6"] (DIA) X 17mm[0.7"] (D) 110mm[4.35"] (H) X 46mm[1.8"] (W) X 34mm[1.35"] (D) MAX 10 PER QSM MAX 10 PER QSM *DEVICE IS SURFACE-MOUNTED AND *DEVICE IS SURFACE-MOUNTED AND BATTERY POWERED, DOES NOT BATTERY POWERED, DOES NOT REQUIRE POWER FEED REQUIRE POWER FEED LOCATION TBD LOCATION TBD LRF3-VCRB-P-WH 868MHZ WIRELESS VACANCY SENSOR 102mm[4.0"] (DIA) X 33mm[1.3"] (D) MAX 10 PER QSM *DEVICE IS SURFACE-MOUNTED AND BATTERY POWERED, DOES NOT REQUIRE POWER FEED LOCATION TBD (OPTION:WITH L-CRMK-WH RECESS MOUNT KIT FOR NON-METALLIC CEILINGS) LUTRON Q TO ADDITIONAL ENERGI SAVR NODES & SENSOR MODULES TO DUPLEX RECEPTACLE BY OTHERS QSM RULES 4 WIRED DEVICES MAX (OF ANY COMBINATION) 10 WIRELESS OCCUPANCY SENSORS 10 WIRELESS DAYLIGHT SENSORS 10 WIRELESS PICOS OPTIONAL GREEN GLANCE UPS UNINTERRUPTIBLE POWER SUPPLY BY LUTRON QS-A-CMP-S/R QUANTUM LIGHTING MANAGEMENT SYSTEM DEDICATED SERVER. TOWER CASE OR RACK MOUNT CAN BE PROVIDED. CUSTOMER PROVIDED SERVER MUST MEET SPECIFICATION DETAILED IN QS-A-CMP-BO-0 SPEC. SHEET. TO BE LOCATED IN CUSTOMERS CORPORATE DATA CENTER. INSTALLATION TO MEET SPECIFICATIONS AND REQUIREMENTS IN QS-A-CMP-R-0 SPEC SHEET. LRF3-OCRB-P-WH 868MHZ WIRELESS OCCUPANCY/VACANCY SENSOR 102mm[4.0"] (DIA) X 33mm[1.3"] (D) MAX 10 PER QSM *DEVICE IS SURFACE-MOUNTED AND BATTERY POWERED, DOES NOT REQUIRE POWER FEED QSM3-4W-C QUANTUM SENSOR MODULE (QSM) WITH (4) UNIVERSAL WIRED INPUTS AND 868MHZ WIRELESS RECEIVER 18.29m[60'] RADIUS RF COVERAGE (9.14m[30'] THROUGH WALLS) 102.6mm[4.04"] (DIA) X 29.7mm[1.17"] (D) LOCATION TBD Q TO ADDITIONAL ENERGI SAVR NODES & SENSOR MODULES TO QUANTUM SERVER OR LIGHTING MANAGEMENT NETWORK SWITCH E DVI DIGITAL SIGNAL WIRING LEGEND: QS-A-CMP-D-0 GREEN GLANCE CLIENT PC (CUSTOMER SUPPLIED PC MUST MEET MINIMUM SPECIFICATION OF MODEL QS-A-CMP-DB0-0) LOCATION TBD USER-SUPPLIED GREEN GLANCE DISPLAY (MINIMUM RESOLUTION 1024 X 768) Q WIRING NOTES: QS CONTROL LINK (SEE WIRE DESCRIPTION BELOW) Q QS CONTROL LINK (SEE WIRE DESCRIPTION BELOW) (CONNECT WIRES 1, 3 AND 4. DO NOT CONNECT WIRE # 2) QS WIRING AS REQUIRED BY CONTROL LINK LENGTH (REFER TO QS SMART PANEL POWER SUPPLY WIRING GUIDE FOR SHADE WIRING NOTES): TOTAL CONTROL LINK LENGTH Wire Gauge AVAILABLE FROM LUTRON IN ONE CABLE: INPUT POWER (NORMAL) QS LINK RULES: THE FOLLOWING LINK RULES MUST BE OBSERVED FOR PROPER OPERATION: INPUT POWER (NORMAL-EMERGENCY) 2 #12AWG (4 mm2) THIS IS A TOPOLOGY-FREE LINK (T-TAP, HOME-RUN, ETC. IS OK); REFER TO TABLE BELOW FOR WIRE RUN LIMITS. IF WIRED DIFFERENTLY THAN WHAT IS SHOWN, POWER DRAW UNIT REQUIREMENTS NEED TO BE CONFIRMED; SEE POWER DRAW UNITS (PDUs) SPECIFICATION SHEET INCLUDED IN THIS SUBMITTAL. MAXIMUM OF 512 OUTPUTS (BALLASTS, SHADES, CONTACT CLOSURES, ETC). MAXIMUM OF 100 OCCUPANCY SENSORS, 100 DAYLIGHT SENSORS/RADIO SHADOW SENSORS AND 100 KEYPADS. 3 #12AWG (4 mm2) 0-10V SIGNAL: 2 #18AWG (1.0 mm 2) 2 #18AWG (1.0 mm 2) POWER (TERMINALS 1&2): LESS THAN 500ft (153 m) DATA (TERMINALS 3&4): 3 #18AWG (1.0 mm 2) GRX-CBL-346S OR GRX-PCBL-346S TWISTED AND SHIELDED* 500ft (153 m) TO 2,000ft (600 m)** MAXIMUM OF 100 ZONES - SUCH AS A SIVOIA QS SHADE / DRAPERY DRIVE UNIT, OR A LIGHTING ZONE ON A GRAFIK EYE QS (DOES NOT APPLY TO QUANTUM SYSTEMS). THE 10 OUTPUTS ON A QSPS-Px-10-60 CANNOT EXCEED A COMBINED LENGTH OF 2,000 ft (600 m). LUTRON SENSOR CABLE C-CBL-522S OTHERWISE USE 3 #18 AWG (1.0 mm2) LUTRON SENSOR CABLE C-CBL-522S OTHERWISE USE 4 #18 AWG (1.0 mm2) ECOSYSTEM BUS/LOOP RULES: THE FOLLOWING LOOP RULES MUST BE OBSERVED FOR PROPER OPERATION: POWER (TERMINALS 1&2): DATA (TERMINALS 3&4): GRX-CBL-46L OR GRX-PCBL-46L TWISTED AND SHIELDED* *ALTERNATE DATA-ONLY CABLE: USE APPROVED DATA LINK CABLE (22 AWG [0.5 mm ] TWISTED/SHIELDED) FROM BELDEN (MODEL # 9461). **TOTAL LENGTH OF THE QS LINK MUST NOT EXCEED 2,000 ft (600 m). THIS IS TOPOLOGY-FREE AND POLARITY FREE WIRING (T-TAP, HOME-RUN, ETC. IS OK). KEEP ALL THE BALLASTS/MODULES IN ONE ROOM ON THE SAME LOOP WHENEVER POSSIBLE. WIRE DAYLIGHT SENSORS, OCCUPANCY SENSORS AND PERSONAL CONTROLS TO THE CLOSEST ECOSYSTEM BALLAST/ SENSOR MODULE IN THE SAME ROOM. ECOSYSTEM LOOPS ARE SHOWN ON THE LIGHTING PLANS. IF THERE IS A DISCREPANCY, AND ROOMS ARE WIRED TO A DIFFERENT LOOP THAN THE ONE SHOWN, LUTRON NEEDS TO BE NOTIFIED. THIS INFORMATION IS IMPORTANT FOR PROGRAMMING THE SYSTEM. UP TO 64 BALLASTS/MODULES PER ECOSYSTEM LOOP UP TO 64 IR CONTROLS PER LOOP UP TO 16 DAYLIGHT SENSORS PER LOOP UP TO 32 OCCUPANT SENSORS PER LOOP E CAT5E OR BETTER CABLE FOR LUTRON NETWORK TERMINATED WITH RJ45 CONNECTORS (TO BE PROVIDED BY OTHERS). 328 ft (100 m) MAXIMUM RUN. F FIBER OPTIC CABLE FOR LUTRON NETWORK TERMINATED WITH APPROPRIATE FIBER OPTIC CONNECTORS (TO BE PROVIDED BY OTHERS). NOTE: REQUIRES DEDICATED FIBER OPTIC LINK (SINGLE-MODE OR MULTI-MODE). D DMX CONTROL ECOSYSTEM BUS/LOOP: LUTRON CABLE C-CBL-216-GR-1 (2 #16 CONDUCTOR NON-PLENUM) OR C-PCBL-216-CL-1 (2 #16 CONDUCTOR PLENUM RATED). OTHERWISE USE 2 #16 AWG (1.5 mm 2) BY OTHERS. QUANTUM NETWORK TYPICAL QUANTUM WITH WIRELESS SENSORS WHEN A LIGHTING MANAGEMENT NETWORK (LMN) IS REQUIRED TO ENABLE COMMUNICATIONS BETWEEN INDIVIDUAL LIGHT DALI LINK THE LMN. 1-WAY RF COMMUNICATION THE NUMBER OF ETHERNET HOPS/SEGMENTS BETWEEN THE SERVER/DESKTOP/LAPTOP (Q-MANAGER) AND ANY LMN NODE SHALL 2-WAY RF COMMUNICATION CONCEPT DRAWING IF LONGER RUNS ARE REQUIRED, MULTI-MODE FIBER OPTIC CABLE CAN BE USED INSTEAD WITH APPROPRIATE FIBER OPTIC RULES FOR DISTANCE AND SEPARATION AS WELL AS FOR PLACEMENT OF SWITCHES, ROUTERS, HUBS, ETC. FOR MORE INFORMATION REGARDING NETWORK EQUIPMENT REQUIREMENTS AND NETWORK CONFIGURATION, PLEASE REFER TO THE QUANTUM LIGHTING MANAGEMENT NETWORK SPECIFICATION SHEET OR CONTACT LUTRON. P PANEL LINK (SEE WIRE DESCRIPTION BELOW) P PANEL LINK (SEE WIRE DESCRIPTION BELOW) (CONNECT WIRES 1, 2, 3 AND 4. DO NOT CONNECT WIRE # 5) NOT FOR CONSTRUCTION LUTRON CABLE GRX-CBL-46L (5 CONDUCTOR NON-PLENUM) OR GRX-PCBL-46L (5 CONDUCTOR PLENUM RATED). Concept Drawing Notes: Control system drawing is provided for conceptual purposes only and is not intended for verified in accordance with the most up-to-date lighting/electrical reflected ceiling plans, equipment should be verified in accordance with architectural plans, specifications and window schedules/details. Project Number: EMERGENCY SENSING CABLE BY OTHERS. Drawn By: N/A MLG 0 Drawing Revision: Drawing Date: 7.8.13 Sheet: 1 OF 1 Lutron Electronics Co., Inc. 7200 Suter Road | Coopersburg, PA 18036 | USA (610) 282-3800 | fax: (610) 282-1146