   EMBED


Share

Transcript

208/230-60-1 POWER SOURCE 11 BLACK COM Optional 3 Pin Plug For ERV R L1 T1 Compressor 19 Contactor S 21 Capacitor L2 19 Compressor Contactor C Compressor 240 208 Transformer T2 Use for 208V operation COM 15 29 10 B 12 10 RED/ WHITE 48 27 240V 208V BLACK/WHITE 55 C COM 31 RED Transformer 10 35 Y C 3 2 4 7 G 6 9 14 DEHUM RELAY 12 PIN VENT PLUG 27 3 Y2 5 4 6 2 Y1 FREEZE T-STAT 4 5 O 1 W R DEHUM LOGIC 58 36 A A2 G1 Yo A1 G Y D 1 7 8 9 C 12 LOW R C VOLTAGE STRIP 10 11 12 27 RED 12 11 10 9 8 7 6 5 4 3 2 1 12 PIN VENT PLUG 1 2 3 27 High Speed Solenoid 27 BLACK/WHITE BLUE PURPLE BLACK/WHITE 48 Reversing Valve Three way Valve CAPACITOR CHART MODEL CAPACITOR QW2S 35/370 QW3S 40/370 QW4S 45/370 QW5S 80/370 BLUE/WHITEFlow Switch BLUE/BLACK YELLOW R 53 S 2 OPTIONAL 3 PIN PLUG FOR ERV BLUE 27 BLACK/WHITE FOR ANTIFREEZE LOOP APPLICATIONS, CONNECT THE LOW PRESSURE SWITCH WITH YELLOW LEADS IN PLACE OF THE LOW PRESSURE SWITCH WITH BLUE LEADS. ONE LEAD WILL CONNECT TO BROWN LEAD FROM THE FLOW SWITCH, AND THE OTHER WILL CONNECT TO THE YELLOW LEAD COMING FROM THE LPC TERMINAL OF THE COMPRESSOR CONTROL MODULE. ALR 1 A E TWV BLACK/ WHITE 39 21 Capacitor 2 18 BLACK/WHITE 39 Check Light 230/208-60-1 VOLT PACKAGE UNIT DIAGRAM R LPC LPC 39 35 32 15 CC 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 6 PIN 27 CO2 PLUG 1 RED RED RED C 1 3 10 12 PIN PLUG FOR THERMOSTAT BLACK 99 BLUE Compressor Hi Pressure Control Low Pressure Control ! YELLOW R 30 38 BLACK/WHITE 6 38 HPC YELLOW 4 5 GREEN T2 B L Compressor 24 Control Module BROWN 3 ORANGE T1 37 YELLOW/RED 19 BLUE 2 39 RED/ WHITE 38 L2 BLUE 1 53 L1 10 LOW VOLTAGE STRIP 38 BLUE/BLACK 54 REVERSING VALVE BROWN A 24 THREE WAY VALVE RED 9 C Compressor Control Module LPC 34 RED 6 7 ALR LPC 2 12 3 1 PINK 34 Compressor Contactor 4 9 Y CC R 27 BROWN RED/WHITE 10 YELLOW 10 3 10 13 14 15 6 HPC Low Pressure Switch 16 PIN PLUG FOR INDOOR BLOWER MOTOR 10 Ground Terminal 4 56 1 19 Compressor Contactor Flow Switch BLACK 53 5 Circuit Breaker BLACK RED BLACK/WHITE 28 YELLOW DEHUM RED/WHITE REMOVE WIRE FROM TERMINAL Y2 AND TAPE OFF WHEN LOWER FULL LOAD CFM DESIRED 3 BLACK 10 YELLOW 3 2 High Pressure Switch PINK BLUE/BLACK PINK FOR 208 VOLT OPERATION, MOVE THIS RED WIRE TO 208 VOLT TRANSFORMER TAP 1 L2 5 Circuit Breaker YELLOW 10 PURPLE 14 RELAY BROWN RED/WHITE BLACK/WHITE 2 RED COM 208V 240V R 10 RED/WHITE 1 4 Ground 24VAC YELLOW BLUE 6 PIN CO2 PLUG 27 GREEN RED/WHITE BROWN BLUE GRAY YELLOW 10 57 10 BLUE RED/WHITE 8 9 10 11 12 RED/WHITE BLACK/WHITE Brown BROWN/WHITE YELLOW 7 BLUE BROWN 50 BROWN/WHITE 5 6 ORANGE YELLOW YELLOW 10 PURPLE 4 BROWN/WHITE RED/YELLOW BROWN 2 3 55 RED/YELLOW PURPLE PURPLE 3 24VAC 3 BLACK/WHITE BLACK/WHITE 1 54 Circuit 5 Breaker Transformer ORANGE PURPLE/WHITE 4 11 5 Pin Plug 5 for Indoor Blower Motor 208/230-60-1 POWER SOURCE BLACK C 53 5 L1 240 208 GREEN 10 4 L1 L2 10 YELLOW 10 3 5 PIN PLUG FOR INDOOR BLOWER MOTOR RED 52 51 12 PIN PLUG FOR THERMOSTAT 10 ORANGE YELLOW YELLOW FREEZE THRMOSTAT PURPLE DEHUM. CONTROL 49 BLACK BLACK/WHITE BLACK 14 12 15 3 1 10 6 9 13 2 RED/WHITE 16 PIN PLUG FOR INDOOR BLOWER MOTOR 10 Low Pressure Control Wire Identification numbers for Bard use only. Factory Field Optional Flow Switch DANGER *ELECTRICAL SHOCK HAZARD *DISCONNECT POWER BEFORE SERVICING. ! WARNING USE COPPER CONDUCTORS ONLY SUITABLE FOR AT LEAST 75° C. High Voltage Low Voltage 4113-104 A