Preview only show first 10 pages with watermark. For full document please download

Manual 13768479

   EMBED


Share

Transcript

OCCUPANCY & PIR DETECTORS Recessed Ceiling Mount Detector Surface Ceiling Mount Detector ●● Building Controls ●● ●● ●● ●● ●● ●● PIR 2kW. 360˚ Recessed. Time lag range: 15 seconds to 30 minutes. Photo cell range: 40-2000 Lux. ●● ●● IP44 Part No Description Ref 449123 Ceiling Mount SSPIROS R Wall Mount Detectors ●● ●● Part No Description 449125 449124 2 Wire (1kW Fluorescent) 3 Wire (neutral required) 2kW (1kW Fluorescent) Surface Mount (IP44) 449122 Ceiling Mount SSPIROS S Ref SSPIROS2W SSPIROS3W ●● ●● ●● ●● ●● ●● ●● Ref Microwave Detector Professional PIR Detectors ●● Description PIR operated wall switch. 2kW. Part No ●● Includes plug-in detector & base to simplify and speed up installation. PIR 2kW. 360˚ Surface. Time lag range 15 seconds to 30 minutes. Photo cell range 40-2000 Lux. Switching Capacity: 2300W resistive 12m detection range with 180˚ area of detection Light ON times adjustable from 5 seconds to 5 minutes. Adjustable light level control. 3 year guarantee. IP55 Part No Description 447626 447627 PIR 180˚ - 2.3kW (Black) PIR 180˚ - 2.3kW (White) 16A Switching regardless of load type. Timing from 2 min to 2 hours. Lux level and Daylight adjustment. A high performance presence detector. 30m range and replaces multiple PIRs. Occupancy sensors in corridors with one easy to mount unit. Part No Description 452212 Microwave Range Detector with Surface Pattress Ref SSMICOS Directional Surface Mount Detectors Ref SNSLB2000 SNSLW2000 PIR Detectors ●● ●● ●● ●● ●● ●● ●● 52 Switching Capacity: 2300W resistive 12m detection range with 180˚ area of detection Light ON times adjustable from 5 seconds to 5 minutes Adjustable light level control. 3 year guarantee. ●● ●● IP55 Part No Description 447607 447608 PIR 140˚ - 1kW Black PIR 140˚ - 1kW White Ref S1000B S1000W Time lag range: 10 secs - 40 mins in 9 steps. Photocell range: 100 - 1000 lux, and inactive. Loading: Up to 6 amps (1500W) of any type of load (including fluorescent lights and fans). Standard Version Detection zone: 120˚, range 5m walking towards, 10m walking across. Long Range Version Ideal for corridors and storage aisles. Detection zone: 6˚, range up to 25m. Part No Description 452041 452042 452040 Direction PIR Standard 1.5kW Direction PIR Long Range 2kW (1kW Fluorescent) Plug In Mounting Base and Socket www.wfsenate.co.uk IP44 Ref SSPIROS DIR SSPIROS DIR LR SSPIROS DIR SK PHOTOCELLS & SECURITY SWITCHES Wireless PIR Detector ●● ●● PIR detector - no mains wiring adjustable 12m detection range with 180˚ detection area. 6 different alarm sounds. Controls plugged in appliances. Part No Description 447635 PIR with RF Transmitter and 400W Plug In Alarm Ref STRXDC1 Photo Electric Cells ●● ●● Building Controls ●● Photo Electric Cells (NEMA Head) ●● ●● Description 451781 449381 20mm Photocell Miniature Unit 20mm Photocell and Remote Unit Part No Description 452043 449384 452044 Photo Electric Head only Photo Electric Cell Kit Part Night Cell Kit Ref SPEC4E SPEC4EKIT SPEC9PN Programmable Security Light Switch Mounts in 20mm dia. aperture. Switch 1kW resistive 600W inductive. Part No Switch 1kW resistive 600W Inductive. Surge protection included. Ref SPEC20 SPEC20/R Time and Lux Adjustable Photo Electric Cells ●● ●● ●● ●● ●● ●● Energy efficient. Integral timeswitch. Allows on at dusk with fixed time off. Part No Description 447957 Variable Photo Electric Cell Ref SVAR04 Easy to install, replaces normal light switch (suitable for 1 way or 2 way). Timer activated switch off. Light ON time programmable up to 8hr approximately. Part No Description 451806 Wall Mount 40W min 300W max Ref S210SS Time Lag Switch Digital Security Light Switch ●● ●● ●● ●● ●● 24 hours, 7 day programmable light switch Easy to install, replaces normal 1 way light switch. Optional dusk start. Max 300W incandescent, 76W fluorescent, 25W low energy, 200W low voltage. 6 x on/off switching programmes. ●● ●● ●● Part No Description 451807 24 Hour - 7 Day Digital Time Switch Ref SZ700 Easy to fit - replaces existing lighting control. For fluorescent 3A and incandescent 5A lighting. Adjustable time delay from 20 secs to 25 mins. Part No Description 452210 452207 Electronic Time Lag Switch Pneumatic Time Lag Switch www.wfsenate.co.uk Ref S400E S400A 53 TIMERS & CONTROLLERS Electronic Time Delay Switches Hard Wired Mechanical Time Switches ●● Building Controls ●● ●● ●● ●● ●● ●● ●● ●● Master: 2 wire connection Neutral not required. Slave: 3 wire connection Neutral not required. Neon button highlights switch in dark areas. Replaces any conventional single gang (ON/OFF) light switch. Adjustable light ON times from 10 secs to 10 mins approx. via a tamperproof potentiometer. For use with incandescent lighting up to 1.5kw and 20-200W of low voltage lighting (not suitable for fluorescent and low energy lighting). Wall mounted. Part No Description 451805 451804 Time Delay Switch - Master (Wall) Time Delay Switch - Slave (Wall) ●● ●● ●● Industry standard 20A 3 pin round pattern timer switch. Can be used as a direct replacement for single channel On/Off switching. 24 On/Off programmes in 24 hours. Half day(s) and day(s) omit unlimted over a 7 day period. Permanent on facility and a manual override. Round Pattern Timer Part No Description 449182 3 Pin 20A 24 On/Off + Day Omit Ref SRTS113 Ref SDS1MASTER SDS1SLAVE ●● ●● ●● Plug-In Time Switches ●● Ideal for Immersion Heaters Minimum setting time is 15 mins. Minimum On/Off period 30 mins. 13A resistive - 2A inductive. Thermal fuse included. General Purpose Tappet Pin Timer ●● ●● ●● ●● Minimum setting 30 mins. Self cancelling override switch. 13A resistive - 5A inductive. Manual override until next programme change. Part No Description Ref 449172 24 Hr Timer S24GPIHT ●● ●● Ref ●● S24NCT ●● Description Tappet Pins Timer 449175 Plug-In Timer Part No ●● Up to 4 On/Off programmes per day. Shortest switching time 1 minute. Automatic Summer/Winter changeover. 720 hr Rechargeable memory backup. Switches up to 750W incandescent or halogen lighting. Fused Connection Unit with Timer General Purpose Digital Timeswitch ●● ●● ●● ●● ●● ●● 54 Up to 4 on/off programmes per day. Switched and switched/ timed outputs. Simple two button timing. Self cancelling override. 1000 hour rechargeable memory Fits 1 gang 25mm deep box. Part No Description 451808 451809 24 Hour 7 Day Part No Description 568501 568502 24hr Slimline Electronic General Purpose Timeswitch 7 Day Slimline Electronic General Purpose Timeswitch ●● ●● ●● Ref SFST11 SFST17 Ref SNTT06 SNTT07 Ideal for Immersion Heaters Switches on and off at preset times. 30 min minimum switching permanent On/ Off control. Fits 1G 32mm deep box. Compact Segment Timer Part No Description 568500 24 Hr Timer 16A / 8A www.wfsenate.co.uk Ref SNTT01 ELECTRICITY METERS & CTs Current Transformers for CT Meters ●● ●● Split core clips around existing cables without disconnection Up to 300A Dims 89x109x40 - Cable hole 21x32 From 400A Dims 115x145x51 -Cable hole 50x80. Accuracy Class1 @2.5VA (100A model Class3 @1.5VA). Description Split Core CTs (5A secondary) 451759 5A / 100A CT 451761 5A / 200A CT 451763 5A / 300A CT 451765 5A / 400A CT Ref SCT100SPLIT SCT200SPLIT SCT300SPLIT SCT400SPLIT Current Transformers for CT Meters ●● ●● ●● ●● Building Controls Part No Current measuring device for use with CT operated meters. Cable feeds through solid core Up to 300A Dims 45x65x30 - Cable hole 21dia. From 400A Dims 85x108x50 - Cable hole 45dia. Accuracy Class1 @ 2.5VA. Higher currents available on request. Part No Description Solid Core CTs (5A secondary) 451753 5A / 100A CT 451754 5A / 200A CT 489419 5A / 300A CT 451755 5A / 400A CT Ref SCT100SOLID SCT200SOLID SCT300SOLID SCT400SOLID Current Transformers for CT Meters ●● ●● ●● ●● Measures all three phases with one CT Cable feeds through solid core Can fit next to switch in distribution board. Dims 105x70x53. Three cable holes 21x25. Accuracy Class1 @ 2.5VA. Part No Description 3 in1 Solid Core CTs (5A secondary) 451760 5A / 100A CT 451762 5A / 200A CT 451764 5A / 300A CT 489420 5A / 400A CT Ref SCT100THREE SCT150THREE SCT200THREE SCT250THREE Prepayment Meters ●● ●● ●● ●● ●● Secure system - no unattended cash left in meter. 230 AC Voltage 50Hz. Emergency credit facility. Utilising non re-usable cards. 1, 5,10 and 20 meter cards available in £ and €. Part No Description Electronic kWh Card Meter 451775 100A New 451766 100A Recon Electronic kWh Dual Coin Meter 451773 100A £1 and £2 Coin Operated Time Switch 451776 100A £1 and 20p Ref SCARDMETER/N SCARDMETER SM100 SM100/T www.wfsenate.co.uk 55 ELECTRICITY & PRE-PAYMENT METERS Conventional Electricity Meters Panel and DIN Rail Mounted Meters Building Controls ●● ●● ●● ●● ●● ●● Direct Connection of cable (CT’s not required). 230V AC 50-60Hz 20-100A or 415V AC 50-60Hz 20-100A. Pulsed output for datalogger use. Single Phase Digital kWh Single Phase DIN Rail Mount Part No Description 447852 CTs Required - Max 400A 447853 100A, Direct Connection Three Phase DIN Rail Mount Part No Description 451769 100A, Direct Connected Part No Description Ref 451767 451752 100A New 100A Recon SEM100/N SEM100 Ref SDR45A/1 SDR100A/1 Ref ●● SDR100A/3 ●● ●● ●● ●● Multi Function kWh Meter Requires Current Transformers (CTs 5A secondary). 240V AC 50-60Hz 4 Wire Three Phase and Neutral Din Rail Mount. Pulsed output for datalogger use. ●● Description 451772 CTs Required - Max 400A ●● ●● ●● ●● 451774 CTs Required - Max 400A Description 451770 451768 100A New Dir Con 100A Recon Dir Con ●● ●● ●● Three Phase CT operated Panel Mount Description Part No Requires Current Transformers (CT’s / 5Amp) 2x230/415V AC 50-60Hz Sealable case and terminal cover. OFGEM approved and certified. Pulsed output for connection to a datalogger. Three Phase CT operated kWh Ref Part No Description SPR215A 451771 CTs Required - Max 400A Mobile SIM Card Smart Meters ●● ●● ●● Built in mobile phone technology transmits readings over GSM network. Meter owner can open own remote reading account on Meteronline website. OFGEM approved and certified for billing & Solar PV feed in tariff. Part No Description Single Phase kWh Direct Connected with Sim Card 489163 100A Recon Three Phase kWh Direct Connected with Sim Card 451777 100A New Three Phase kWh CT operated with Sim Card 451778 100A New (5A CTs extra) 56 Ref S3P100/N S3P100 Ref SDR215A Multi Function kWh Meter Requires Current Transformers (CTs 5A secondary). 240V AC 50-60Hz 4 Wire Three Phase and Neutral Standard Panel mount 96x96 Shows kWh, Amps, Volts, kW, kVA, kvar, PF etc. Pulsed output for datalogger use. Part No Direct Connection of cable (CT’s not required) 2x230/415V AC 50-60Hz 20-100A Sealable case and terminal cover. New meter extra features include OFGEM approved and certified. Pulsed output for connection to a datalogger. Three Phase Direct Connected kWh Three Phase CT operated DIN/Panel Rail Mount Part No Direct Connection of cable (CT’s not required) 230V AC 50-60Hz 20-100A Sealable case and terminal cover. New meter extra features include OFGEM approved and certified. Pulsed output for connection to a datalogger. Ref SEM100/SIM S3P100/SIM S3P5CT/SIM+ www.wfsenate.co.uk Ref S3P5/CT+