Preview only show first 10 pages with watermark. For full document please download

Manual 13784432

   EMBED


Share

Transcript

Access/Series V Ceiling recess case now. Install screen/roller assembly later at job site by Specifications—Access/Series V Projection screens, size h. x w., for recessed ceiling mounting. Case finished white. Back, top, and front of extruded aluminum. Endcaps are stamped steel. Bottom panel forms slot for passage of viewing surface, easily removable for access. Symmetrical housing to allow for left or right-hand motor location and for viewing surface to unroll from the back or front of the roller. Housing to include bottom flange for trim around edges of ceiling opening. Case may be mounted with 3/8" threaded rod, with lag screws through brackets, or with wire in a grid ceiling. Mounting brackets slide in channels on top of case, allowing brackets to be moved to avoid interference with conflicting building structures. Brackets lock in position by tightening screws. Brackets may also be angled to meet installation requirements. Roller/fabric assembly may be installed in case at factory or job site. Brackets supporting roller/fabric assembly to slide in a track inside the top of the case, allowing viewing surface to be centered in case regardless of screen size. Roller of 3" dia. metal. Viewing surface with black masking Please Mark Appropriate Selections Select Shipping Option: Case Now, Screen Assembly Later 1 Complete Unit Now borders. Each side of surface to have tab-guide cable system for even lateral tension and flat surface. Bottom of surface supported and masked by black extruded aluminum dowel weighted to apply proper vertical tension. Top of viewing surface masked by 12" black drop. Viewing surface flame and mildew resistant. M1300 and HiDef Grey viewing surfaces shall qualify as low emitting and meet all of the requirements of the GREENGUARD for Children and Schools and GREENGUARD certification program. Electrically operated 110-120V AC, 60 Hz. 3-wire motor mounted inside screen roller, 1.1 amp draw, instantly reversible, lifetime lubricated, with internal thermal overload protector and electric brake,and preset limits. Housing to feature internal junction box, allowing it to be installed and wired to building supply wires at an early stage of construction. Junction box to have plug-in style connector, accepting the mating half of the connector from the motorized roller/fabric assembly. 3-position control switch to stop or reverse screen at any point. Switch(es) furnished with cover plate. Patented by Draper, Inc. (U.S. Patent Nos. 6,137,629; 6,421,175; and 6,532,109), other patents pending. Entire unit certified by Underwriters’ Laboratories for the U.S. and Canada. Plenum rated case (UL approved “Suitable for Use in Environmental Air Space”). Downloadable 3-part specifications are available at www.draperinc.com. Dimensions & Data Select Viewing Surface: Size Case Dowel Net Wt. Qty. H xW Length 4 Length (lbs.) Audio Visual Format 50" x 50" 75" 601/8" 58 60" x 60" 86" 711/8" 66 1 70" x 70" 96" 85 /8" 69 1 74 84" x 84" 111¼" 96 /8" 72" x 96" 122" 1081/8" 92 Select Motor and Controls: 96" x 96" 12¾" 1095/8" 92 Standard Voltage Motor and Control Options: 7' x 9' 135¼" 1201/8" 95 110-120V AC (standard) 9' x 9' 136¾" 1221/8" 95 2 Optional Quiet Motor 8' x 10' 148¾" 1335/8" 99 Please Note: These motors come with one 110V-120V AC 3-position wall switch 7 10' x 10' 150½" 135 /8" 109 (silver wall plate with black rocker). 1 9' x 12' 172¾" 158 /8" 110 Total number of 110-120V AC switches (operate independently) 12' x 12' 178½" 1615/8" 121 Substitute white switch(es) for silver wall plate with black rocker Nominal Image Case Dowel Net Wt. Qty. Optional Key Operated Switch Diagonal Area Length 4 Length (lbs.) Power Supply Key Switch (On-off) NTSC Video Format (4:3) 3-Position Key Control 6' 42½" x 56½" 81½" 665/8" 60 3-Position Switch with Hinged Key-Locking Coverplate 7' 50" x 66½" 91½" 765/8" 68 Low Voltage Motor and Control Options: 1 100" 60" x 80" 105" 91 /8" 73 Optional External LVC-III Low Voltage Control Module 1 10' 72" x 96" 122" 108 /8" 92 Optional Motor with Built-in Low Voltage Controller 1 1 11' 78" x 104" 131¼" 116 /8" 98 Optional Quiet Motor 2 with Built-in Low Voltage Controller 1 150" 87" x 116" 143¼" 1295/8" 104 Please Note: Select Control Options for Low Voltage from below. 15' 108" x 144" 172¾" 1581/8" 110 24 Volt 3-Button Switch Number of 24V switches: 200" 118" x 158" 187¾" 1737/8" 135 Radio Frequency Remote Control (only with 24v) HDTV Format (16:9) Infrared Remote Control (only with 24v) 92" 45" x 80" 105" 901/8" 76 Optional Key Operated Switch 100" 49" x 87" 111" 971/8" 80 Power Supply Key Switch (On-off) 1 106" 52" x 92" 117" 102 /8" 80 3-Position Key Control 1 110" 54" x 96" 121" 107 /8" 80 3-Position Switch with Hinged Key-Locking Coverplate 119" 58" x 104" 129" 1151/8" 85 MC1/Serial or Network Communication (please see and complete a 133" 65" x 116" 142" 1271/8" 89 Serial and Network Screen and Lift Control Planning Sheet) 161" 79" x 140" 167¼" 1521/8" 106 3 Optional Video Interface Control (not compatible with other controls) 184" 90" x 160" 187¾" 1735/8" 133 VIC-115 Override Switch Override Switch (VICs are compatible only 16:10 Format VIC-12 Override Switch not available if with the Override Switch, 1 94" 50" x 80" 104" 90 /8" 76 VIC-6 Override Switch VIC is built-in. and not with any other 109" 57½" x 92" 117" 1031/8" 80 wall switches or controls) 1 Select Motor Location: 123" 65" x 104" 129" 115 /8" 85 Left end (standard) 137" 72½" x 116" 142" 1281/8" 89 Right end 165" 87½" x 140" 167½" 1535/8" 106 Optional Accessories: 189" 100" x 160" 187½" 1735/8" 153 Additional set of mounting brackets for alternate mounting (see page 2) Custom Size 4 Additional Drop (Beyond standard 12") 4 Total Drop (Standard 12" + Additional drop) Extra drop will increase case and dowel length. Specify at time of order and conBlack (standard) tact Draper if this dimension is critical. Case sizes include 1" flange on each end of Same color as viewing surface case. Subtract 2" for rough ceiling cutout size. 1 2 Please note: When ordering a motor with Quiet Motor Size Limitations built-in Low Voltage Controller, if the case ships AV NTSC HDTV 16:10 Also available in 1.85:1, 2.35:1 and 15:9 Formats. Contact Draper. separate from the "guts," the case includes the 96" x 96" 11' 119" 123" 25' cable and special low voltage switch. PROJECT: GREENGUARD for Children and Schools certified M1300 (1.0 gain) M2500 (1.5 gain) (Thru 9' x 12' AV, 15' NTSC, 184" HDTV & 189" 16:10) GREENGUARD for Children and Schools certified HiDef Grey (0.9 gain) (Thru 9' x 12' AV, 200" NTSC, 184" HDTV & 189" 16:10) Optional Cineflex Rear Projection (1.3 gain) Optional Low-Gain Cineflex Rear Projection (0.8 gain) Optional Uniflex White Front (0.5 gain) and Rear (0.7 gain) Projection 3 4 Factory-installed VIC will not increase overall case lengths shown at right. Extra drop increases case and dowel length. Contact Draper if dimension is critical. ® ARCHITECT: CONTRACTOR: SUPPLIER: Copyright © 2010 Draper Inc. Form AccessV_Sub10 Printed in U.S.A. DATE: REVISED: Access/Series V by Draper Page 2 of 2 Case Dimensions and Methods of Installation Typical Installation* Mounting brackets slide left and right as needed. 9" 1" 11 /16" 7" 65/8" 11 /16" 65/8" 21/8" slot L 8" L=varies 1 With typical installation, brackets may be angled to meet installation requirements. Mounting Bracket Dimensions 3 /8" Alternate Installation (additional set of brackets required but not included) 3 11/2" 1 /2" 1 R /4" 5 /16" 3 /16" /16" 1 /8" 13/8" 11/8" 1 /4" 5 1 R /8 " 41/2" /16" 11/4" 1 /4" 413/16" 73/4" 9" Wiring Diagrams2 110-120V Motor and Quiet Motor Internal Screen Wiring White (Common) Black (Down) Red (Up) Green (Ground) Red Blue Single Low Voltage Control Multiple Low Voltage Controls Internal Screen Wiring White (Common) Black (Down) Red (Up) Green (Ground) Internal Screen Wiring White (Neutral) Black Internal Screen Wiring White (Neutral) Black Green (Ground) Green (Ground) Cap off with wire nut and tape Dashed wiring by electrician Control switch 110-120V Motor and Quiet Motor with Built-in Low Voltage Controller Multiple Station Control Single Station Control Single gang box by others Min. 4" x 2 1/8" x 1 7/8" deep Red Dashed wiring by electrician Blue Black Black Blue Red To 110-120V Line Data Cables Wall Switch, RF or IR Receiver, or integrated control system Blue Location of key operated on-off switch if furnished Dashed wiring by electrician Dashed wiring by electrician Black Red Data Cable To 110-120V Line Single gang box by others Min. 4" x 2 1/8" x 1 7/8" deep. 3 shown. More or less equally feasible. Black To 110-120V Line Wall Switches, RF or IR Receivers, or integrated control systems Location of key operated on-off switch if furnished 2 To 110-120V Line Please Note: For external low voltage (LVC-III), serial (MC1) and network (MC1 & LS100) wiring diagrams, please consult instructions for those modules. For more information and wiring diagrams for serial and network communication, please see the Serial and IP Screen and Lift Control Planning Sheet, Draper Screens and Lift Controls Wiring Manual and wiring diagrams supplied with individual items. PROJECT: SUPPLIER: DATE: REVISED: www.draperinc.com (765) 987-7999