Manual 20129181

   EMBED


Share

Transcript

4.LED indicators, Wires, Auxiliary Input and Output Two-door Installation Guide Vision: 1 . 0 . 1 Notes: Date: Oct. 2010 1.Cautions Please note the following cautions.Mis-operation may lead to personal injury or equipment failure: 1)Meaning of LED indicators: 2)Recommended use of wires: LINK indicator(green): always(green) indicates TCP/IP communication is proper; A Use 2-conducotor power cord ACT indicator(yellow):its flashing indicates data is in transmitting through TCP/IP communication. B Use 6-conductor wire between wiegand reader and control panal (RVVP 6*0.5mm) (To choose the proper cord according to the interface you connect, such as 6,8,10 cord.) TX indicator(yellow):its flashing indicates it is sending data through RS485 communication. C Use 4-conducotor lock power cord (RVV 4*0.75mm) RX indicator(green):its flashing indicates it is receiving data through RS485 communication. 1) Do not energize the system before installation is complete; never carry out installation activities when the system is energized. Auxiliary output indicator(green):always(green) indicates it is in use. 2) All peripheral devices must be grounded. Lock indicator(green):always(green) indicates lock is open. 3) It is preferred that all wires run through PVC or galvanized pipes. POWER indicator(red): always(red) indicates control panel is power on. 4) It is strongly recommended that the length of exposed part of any connection cable should not be longer than 4 mm. Professional clamping tools may be used to avoid unintentional contact of exposed wires to avoid short-circuit or communication failure. D Use 2-conducotor switch power cord(RVV 2*0.5mm) 3)The auxiliary input may be connnected to infrared body detectors, alam switches,etc. 4)The auxiliary output may be connected to door bells,alarms,etc. RUN indicator(green):its flashing indicates the system works normally. CARD indicator(yellow):its flashing indicates card is punched on reader. 5) It is recommended that card readers and buttons should be installed at height of 1.4m-1.5m above ground. 6) It is recommended to use the power supply in case for control panel, and external power supply for each lock. LINK IN GND GND 485485+ EXT IN BUTTON1 5 6 7 8 Backup battery Power supply Control panel Advanced Access Control TX RX D Appearance of case Auxiliary output2 A A Power of Control panel 1 Get through the thread hole 2 Fixed case LOCK POWER Power of lock V+ V+12V GND 1 Door2 LOCK2 Thread hole SEN GND NO COM NC BEEP GLED WD1 WD0 GND +12V BEEP GLED WD1 WD0 GND POWER RUN CARD +12V READER4 C { { IN GND READER3 3.Get through the thread hole BEEP GLED WD1 WD0 GND +12V BUTTON2 Door1 SEN GND NO COM NC 1 C NO COM NC LOCK1 Auxiliary output1 Thread hole NO COM NC AUXOUT2 { { D AUXOUT1 Heat dissipation hole GND BEEP GLED WD1 WD0 GND +12V READER2 PC PC RS485 interface TX RX 485+ 485GND READER1 Key hole Extended RS485 output D 1# Door Button B 1#Door wiegand reader B 1#Door wiegand reader { ON 1 2 3 4 2.Components Dip switch { { { { +12V ACT D Auxiliary input2 { (green) flashes. GND Auxiliary input1 { Ethernet interface D { { LAN Connect the system to the power supply.If the system works properly,the POWER indicator(red) is lit constantly and the RUN indicator AUX2 IN SD card AUX1 Description of normal working state: D 2# Door Button B 2#Door wiegand reader B 2#Door wiegand reader 5.RS485 address setting, Restore factory setting, Terminal resistance setting 7.Equipment communication Set RS485 address through DIP switch: The background PC software is able to communicate with the system according to two protocols(RS485 and TCP/IP) for data exchange and remote management. The communication cable should be away from high-voltage lines as far as possible. Do not keep the communication cable in parallel with power cords or bind them together. 1) Place 1-6 on DIP switch are for setting the number of control panel when communicating through RS485, it is adopted for binary coding, and little endian, the address represented by place 1-6 are shown as figurue(5-1). 2) Before setting the address, please keep the system is power off, Jump place 1-6 to desired status, and the address number shall not be the same as another one in the network. For example: to set the device number as 39 (39=1+2+4+32), the corresponding RS485 code is 111001, then Jump place 1,2,3 and 6 at “ON” status. ON 1 2 3 4 5 6 7 1.TCP/IP Communication 8 PC 3) Place 7 is for restoring factory default settings, Jump it for three times within 10 seconds and restart the system, then all information in RAM of control panel will be cleared and the system restores factory default settings. Switch 4) Place 8 is for setting terminal resistance when communicating through RS485. Jump it at “ON” status, then it is equivalent to have a terminal resistance of 120 ohm between 485+ and 485-. 1# control panel n# control panel 2# control panel Diagram of places of DIP switch. LINK LINK LINK AUX2 AUXOUT1 NO COM NC IN GND READER4 GND POWER RUN CARD +12V GND READER3 LOCK POWER BEEP GLED WD1 WD0 V+ V+12V BUTTON2 LOCK2 BEEP GLED WD1 WD0 GND +12V BEEP GLED WD1 WD0 GND +12V 1 LOCK1 SEN GND NO COM NC 1 AUXOUT2 READER4 NO COM NC SEN GND NO COM NC IN GND BEEP GLED WD1 WD0 GND +12V READER2 PC 485+ 485GND GND 485485+ READER1 TX RX BUTTON1 Advanced Access Control EXT 5 6 7 8 BEEP GLED WD1 WD0 GND POWER RUN CARD +12V ON READER3 GND ACT TX RX BUTTON2 LOCK POWER READER4 V+ V+12V 1 2 3 4 READER2 IN GND AUX1 LAN BEEP GLED WD1 WD0 GND +12V BEEP GLED WD1 WD0 GND +12V 1 LOCK2 SEN GND NO COM NC 1 LOCK1 SEN GND NO COM NC BEEP GLED WD1 WD0 GND +12V READER1 AUXOUT2 NO COM NC BUTTON1 AUXOUT1 NO COM NC EXT ON GND TX RX 485+ 485GND PC READER3 GND POWER RUN CARD +12V GND IN Advanced Access Control TX RX BUTTON2 1 BEEP GLED WD1 WD0 V+ V+12V 5 6 7 8 READER2 GND BEEP GLED WD1 WD0 GND +12V 1 2 3 4 BEEP GLED WD1 WD0 GND +12V IN 1 GND POWER RUN CARD +12V GND BEEP GLED WD1 WD0 GND +12V GND 485485+ ACT READER4 LOCK POWER BEEP GLED WD1 WD0 V+ V+12V LOCK POWER BEEP GLED WD1 WD0 GND +12V SEN GND NO COM NC IN GND GND IN GND +12V READER3 LOCK2 Restore factory setting IN GND BUTTON2 LOCK1 SEN GND NO COM NC GND +12V 1 NO COM NC SEN GND NO COM NC 1 AUXOUT2 RS485 terminal resistance BEEP GLED WD1 WD0 READER2 AUXOUT1 32 16 8 4 2 1 NO COM NC SEN GND NO COM NC LOCK2 TX RX NO COM NC LOCK1 8 NO COM NC AUXOUT2 7 AUXOUT1 6 BEEP GLED WD1 WD0 GND +12V READER1 5 PC 4 TX RX 485+ 485GND GND BUTTON1 5 6 7 8 3 Advanced Access Control IN EXT ON 1 2 3 4 2 GND 485485+ GND 485485+ READER1 TX RX +12V ACT TX RX 485+ 485GND BUTTON1 Advanced Access Control PC IN GND AUX2 LAN GND AUX1 IN SD card 1 ACT 5 6 7 8 LINK IN SD card +12V EXT ON 1 2 3 4 ON GND IN GND AUX2 +12V AUX1 IN SD card LAN IN GND AUX2 LAN GND AUX1 IN SD card 2.RS485 Communication figure(5-1) GND 485- 6.Connection of lock 5、门锁连接 485+ 485 serial line Converter 1) Control panel provides lock control output interfaces. For NO lock ,it is open when power is on, and closed when power is off, so COM and NO interfaces should be used; For NC lock, it is open when power is off, and closed when power is on, so COM and NC interfaces should be 485+ 485+ 485+ used. 485- 485- 485- GND GND GND PC 2 3 4 5 1 2) Control panel supports “dry mode” and “wet mode” by setting the jumper, it is “wet mode” when connecting “V+ V-” Input interfaces to supply power for locks, please shorten 2-3 and 4-5 . Equipment factory default setting is dry mode. For setting “dry mode” and 1# control panel 2# control panel 8# control panel “wet mode”, please refer to <>. AUX1 AUX2 AUXOUT1 NO COM NC 7 8 READER4 BEEP GLED WD1 WD0 GND POWER RUN CARD +12V READER3 LOCK POWER GND IN BEEP GLED WD1 WD0 GND +12V BUTTON2 LOCK2 V+ V+12V BEEP GLED WD1 WD0 GND +12V GND 1 LOCK1 SEN GND NO COM NC 1 AUXOUT2 NO COM NC SEN GND NO COM NC READER2 TX RX IN GND BEEP GLED WD1 WD0 GND +12V READER1 485+ 485GND GND 485485+ BUTTON1 TX RX EXT Advanced Access Control PC READER4 BEEP GLED WD1 WD0 GND POWER RUN CARD +12V READER3 GND BEEP GLED WD1 WD0 GND +12V BUTTON2 LOCK POWER V+ V+12V IN GND 1 LOCK2 SEN GND NO COM NC 1 LOCK1 SEN GND NO COM NC BEEP GLED WD1 WD0 GND +12V ACT 5 6 7 8 AUXOUT2 NO COM NC ON AUXOUT1 NO COM NC READER2 PC TX RX BEEP GLED WD1 WD0 GND +12V READER1 TX RX 485+ 485GND IN GND BUTTON1 5 6 7 8 Advanced Access Control 1 2 3 4 GND 485485+ ACT GND IN GND +12V EXT ON GND POWER RUN CARD +12V READER4 GND READER3 BEEP GLED WD1 WD0 V+ V+12V BUTTON2 LOCK POWER GND BEEP GLED WD1 WD0 GND +12V 1 LOCK2 READER3 READER4 BEEP GLED WD1 WD0 GND POWER RUN CARD +12V BUTTON2 BEEP GLED WD1 WD0 GND +12V READER2 IN IN 1 LOCK1 GND BEEP GLED WD1 WD0 GND +12V BEEP GLED WD1 WD0 GND +12V 1 2 3 4 AUXOUT2 SEN GND NO COM NC READER1 GND BUTTON1 V+ V+12V EXT + - SEN GND NO COM NC IN GND 1 + Lock power input NO COM NC GND 485485+ BEEP GLED WD1 WD0 GND +12V 1 FR107 SEN GND NO COM NC LOCK POWER - NC Lock NC SEN GND NO COM NC LOCK2 + Diode NO COM NC LOCK1 - NO COM NC AUXOUT2 COM AUXOUT1 GND NO LOCK TX RX 485+ 485GND TX RX SEN + Advanced Access Control PC - ACT 5 6 7 8 - Enlarged diagram of lock ports Diode ON LOCK + 1 2 3 4 FR107 NO Lock AUXOUT1 +12V NO COM NC BEEP GLED WD1 WD0 GND +12V READER2 TX RX IN GND READER1 PC IN GND AUX2 LAN GND AUX1 IN SD card TX RX 485+ 485GND GND 485485+ BUTTON1 5 6 7 8 LINK Advanced Access Control IN SD card +12V EXT ON 1 2 3 4 ACT GND IN GND LAN +12V AUX2 SD card LAN IN GND AUX2 LAN GND AUX1 SD card IN ON LINK LINK IN 1 2 3 4 5 6 LINK AUX1 3) When the Electrical Lock is connected to the Access Control System, you need to parallel one FR107 diode (equipped in the package) to prevent the self-inductance EMF affecting the system, do not reverse the polarities. DIP switch LED 1 2 3 4 5 Jumper terminal Notes: 1) Internationally accepted RVSP(shielded twisted-pair) wires should be used for communication to effectively avoid interference. RS485 communication wires should be connected by means of bus cascade connection. 2)Considering stability of communication, it is recommended the length of RS485 bus is less than 600m 3) One RS485 BUS may hold 63 units of control panel, but it is not recommended to connect with more than 32 units access control panels.. 4)When the bus is longer than 300m, to enhance the stability of communication, it is necessary to keep place 8 of DIP switches of the first and the last control panel at “ON” status. As shown in the figure above, place 8 of the DIP switches of units 1# and 8# ON is placed at "ON “Wet mode” wiring diagram of lock connecting with external power supply. 1 2 3 4 5 6 7 8 " status.