4.LED indicators, Wires, Auxiliary Input and Output Two-door Installation Guide Vision: 1 . 0 . 1
Notes:
Date: Oct. 2010
1.Cautions Please note the following cautions.Mis-operation may lead to personal injury or equipment failure:
1)Meaning of LED indicators:
2)Recommended use of wires:
LINK indicator(green): always(green) indicates TCP/IP communication is proper;
A Use 2-conducotor power cord
ACT indicator(yellow):its flashing indicates data is in transmitting through TCP/IP communication.
B Use 6-conductor wire between wiegand reader and control panal (RVVP 6*0.5mm) (To choose the proper cord according to the interface you connect, such as 6,8,10 cord.)
TX indicator(yellow):its flashing indicates it is sending data through RS485 communication.
C Use 4-conducotor lock power cord (RVV 4*0.75mm)
RX indicator(green):its flashing indicates it is receiving data through RS485 communication.
1) Do not energize the system before installation is complete; never carry out installation activities when the system is energized.
Auxiliary output indicator(green):always(green) indicates it is in use.
2) All peripheral devices must be grounded.
Lock indicator(green):always(green) indicates lock is open.
3) It is preferred that all wires run through PVC or galvanized pipes.
POWER indicator(red): always(red) indicates control panel is power on.
4) It is strongly recommended that the length of exposed part of any connection cable should not be longer than 4 mm. Professional clamping tools may be used to avoid unintentional contact of exposed wires to avoid short-circuit or communication failure.
D Use 2-conducotor switch power cord(RVV 2*0.5mm) 3)The auxiliary input may be connnected to infrared body detectors, alam switches,etc. 4)The auxiliary output may be connected to door bells,alarms,etc.
RUN indicator(green):its flashing indicates the system works normally. CARD indicator(yellow):its flashing indicates card is punched on reader.
5) It is recommended that card readers and buttons should be installed at height of 1.4m-1.5m above ground. 6) It is recommended to use the power supply in case for control panel, and external power supply for each lock. LINK
IN GND GND 485485+
EXT
IN
BUTTON1
5 6 7 8
Backup battery Power supply Control panel
Advanced Access Control
TX RX
D
Appearance of case
Auxiliary output2
A A Power of Control panel
1 Get through the thread hole
2 Fixed case
LOCK POWER
Power of lock
V+ V+12V GND
1
Door2
LOCK2
Thread hole
SEN GND NO COM NC
BEEP GLED WD1 WD0 GND +12V BEEP GLED WD1 WD0 GND POWER RUN CARD +12V
READER4
C
{ {
IN GND
READER3
3.Get through the thread hole
BEEP GLED WD1 WD0 GND +12V
BUTTON2
Door1
SEN GND NO COM NC
1
C
NO COM NC
LOCK1
Auxiliary output1 Thread hole
NO COM NC
AUXOUT2
{ {
D
AUXOUT1
Heat dissipation hole
GND BEEP GLED WD1 WD0 GND +12V
READER2
PC
PC RS485 interface
TX RX
485+ 485GND
READER1
Key hole
Extended RS485 output
D
1# Door Button
B
1#Door wiegand reader
B
1#Door wiegand reader
{
ON
1 2 3 4
2.Components
Dip switch
{ { { {
+12V ACT
D
Auxiliary input2
{
(green) flashes.
GND
Auxiliary input1
{
Ethernet interface
D
{ {
LAN
Connect the system to the power supply.If the system works properly,the POWER indicator(red) is lit constantly and the RUN indicator
AUX2
IN
SD card
AUX1
Description of normal working state:
D
2# Door Button
B
2#Door wiegand reader
B
2#Door wiegand reader
5.RS485 address setting, Restore factory setting, Terminal resistance setting
7.Equipment communication
Set RS485 address through DIP switch: The background PC software is able to communicate with the system according to two protocols(RS485 and TCP/IP) for data exchange and remote management. The communication cable should be away from high-voltage lines as far as possible. Do not keep the communication cable in parallel with power cords or bind them together.
1) Place 1-6 on DIP switch are for setting the number of control panel when communicating through RS485, it is adopted for binary coding, and little endian, the address represented by place 1-6 are shown as figurue(5-1). 2) Before setting the address, please keep the system is power off, Jump place 1-6 to desired status, and the address number shall not be the same as another one in the network. For example: to set the device number as 39 (39=1+2+4+32), the corresponding RS485 code is 111001, then Jump place 1,2,3 and 6 at “ON” status. ON
1
2
3
4
5
6
7
1.TCP/IP Communication
8
PC
3) Place 7 is for restoring factory default settings, Jump it for three times within 10 seconds and restart the system, then all information in RAM of control panel will be cleared and the system restores factory default settings.
Switch
4) Place 8 is for setting terminal resistance when communicating through RS485. Jump it at “ON” status, then it is equivalent to have a terminal resistance of 120 ohm between 485+ and 485-. 1# control panel
n# control panel
2# control panel
Diagram of places of DIP switch. LINK
LINK
LINK
AUX2
AUXOUT1
NO COM NC
IN GND
READER4
GND POWER RUN CARD +12V
GND
READER3
LOCK POWER
BEEP GLED WD1 WD0
V+ V+12V
BUTTON2
LOCK2
BEEP GLED WD1 WD0 GND +12V
BEEP GLED WD1 WD0 GND +12V
1
LOCK1
SEN GND NO COM NC
1
AUXOUT2
READER4
NO COM NC SEN GND NO COM NC
IN GND BEEP GLED WD1 WD0 GND +12V
READER2
PC
485+ 485GND
GND 485485+
READER1
TX RX
BUTTON1
Advanced Access Control
EXT
5 6 7 8
BEEP GLED WD1 WD0 GND POWER RUN CARD +12V
ON
READER3
GND
ACT
TX RX
BUTTON2
LOCK POWER
READER4
V+ V+12V
1 2 3 4
READER2
IN GND
AUX1
LAN
BEEP GLED WD1 WD0 GND +12V
BEEP GLED WD1 WD0 GND +12V
1
LOCK2
SEN GND NO COM NC
1
LOCK1
SEN GND NO COM NC
BEEP GLED WD1 WD0 GND +12V
READER1
AUXOUT2
NO COM NC
BUTTON1
AUXOUT1
NO COM NC
EXT
ON
GND
TX RX
485+ 485GND
PC
READER3
GND POWER RUN CARD +12V
GND
IN
Advanced Access Control
TX RX
BUTTON2
1
BEEP GLED WD1 WD0
V+ V+12V
5 6 7 8
READER2
GND BEEP GLED WD1 WD0 GND +12V
1 2 3 4
BEEP GLED WD1 WD0 GND +12V IN
1
GND POWER RUN CARD +12V
GND
BEEP GLED WD1 WD0 GND +12V
GND 485485+
ACT
READER4
LOCK POWER
BEEP GLED WD1 WD0
V+ V+12V
LOCK POWER
BEEP GLED WD1 WD0 GND +12V
SEN GND NO COM NC
IN GND
GND IN GND +12V
READER3
LOCK2
Restore factory setting
IN GND
BUTTON2
LOCK1
SEN GND NO COM NC
GND +12V
1
NO COM NC SEN GND NO COM NC
1
AUXOUT2
RS485 terminal resistance
BEEP GLED WD1 WD0
READER2
AUXOUT1
32 16 8 4 2 1
NO COM NC
SEN GND NO COM NC
LOCK2
TX RX
NO COM NC
LOCK1
8
NO COM NC
AUXOUT2
7
AUXOUT1
6
BEEP GLED WD1 WD0 GND +12V
READER1
5
PC
4
TX RX
485+ 485GND
GND
BUTTON1
5 6 7 8
3
Advanced Access Control
IN
EXT
ON
1 2 3 4
2
GND 485485+
GND 485485+
READER1
TX RX
+12V ACT
TX RX
485+ 485GND
BUTTON1
Advanced Access Control PC
IN GND
AUX2
LAN
GND
AUX1
IN
SD card
1
ACT
5 6 7 8
LINK
IN
SD card
+12V EXT
ON
1 2 3 4
ON
GND IN GND
AUX2
+12V
AUX1
IN
SD card LAN
IN GND
AUX2
LAN
GND
AUX1
IN
SD card
2.RS485 Communication
figure(5-1)
GND 485-
6.Connection of lock 5、门锁连接
485+
485
serial line
Converter
1) Control panel provides lock control output interfaces. For NO lock ,it is open when power is on, and closed when power is off, so COM and
NO interfaces should be used; For NC lock, it is open when power is off, and closed when power is on, so COM and NC interfaces should be
485+
485+
485+
used.
485-
485-
485-
GND
GND
GND
PC
2 3 4 5
1
2) Control panel supports “dry mode” and “wet mode” by setting the jumper, it is “wet mode” when connecting “V+ V-” Input interfaces to supply power for locks, please shorten 2-3 and 4-5
. Equipment factory default setting is dry mode. For setting “dry mode” and
1# control panel
2# control panel 8# control panel
“wet mode”, please refer to <>.
AUX1 AUX2
AUXOUT1
NO COM NC
7 8
READER4
BEEP GLED WD1 WD0 GND POWER RUN CARD +12V
READER3
LOCK POWER
GND
IN
BEEP GLED WD1 WD0 GND +12V
BUTTON2
LOCK2
V+ V+12V
BEEP GLED WD1 WD0 GND +12V
GND
1
LOCK1
SEN GND NO COM NC
1
AUXOUT2
NO COM NC SEN GND NO COM NC
READER2
TX RX
IN GND BEEP GLED WD1 WD0 GND +12V
READER1
485+ 485GND
GND 485485+
BUTTON1
TX RX
EXT
Advanced Access Control PC
READER4
BEEP GLED WD1 WD0 GND POWER RUN CARD +12V
READER3
GND
BEEP GLED WD1 WD0 GND +12V
BUTTON2
LOCK POWER
V+ V+12V
IN GND
1
LOCK2
SEN GND NO COM NC
1
LOCK1
SEN GND NO COM NC
BEEP GLED WD1 WD0 GND +12V
ACT
5 6 7 8
AUXOUT2
NO COM NC
ON
AUXOUT1
NO COM NC
READER2
PC
TX RX
BEEP GLED WD1 WD0 GND +12V
READER1
TX RX
485+ 485GND
IN GND
BUTTON1
5 6 7 8
Advanced Access Control
1 2 3 4
GND 485485+
ACT
GND IN GND +12V
EXT
ON
GND POWER RUN CARD +12V
READER4
GND
READER3
BEEP GLED WD1 WD0
V+ V+12V
BUTTON2
LOCK POWER
GND BEEP GLED WD1 WD0 GND +12V
1
LOCK2
READER3 READER4
BEEP GLED WD1 WD0 GND POWER RUN CARD +12V
BUTTON2
BEEP GLED WD1 WD0 GND +12V
READER2
IN
IN
1
LOCK1
GND BEEP GLED WD1 WD0 GND +12V
BEEP GLED WD1 WD0 GND +12V
1 2 3 4
AUXOUT2
SEN GND NO COM NC
READER1
GND
BUTTON1
V+ V+12V
EXT
+
-
SEN GND NO COM NC
IN
GND
1
+ Lock power input
NO COM NC
GND 485485+
BEEP GLED WD1 WD0 GND +12V 1
FR107
SEN GND NO COM NC
LOCK POWER
-
NC Lock
NC
SEN GND NO COM NC
LOCK2
+
Diode
NO COM NC
LOCK1
-
NO COM NC
AUXOUT2
COM
AUXOUT1
GND NO
LOCK
TX RX
485+ 485GND TX RX
SEN
+
Advanced Access Control PC
-
ACT
5 6 7 8
-
Enlarged diagram of lock ports
Diode
ON
LOCK
+
1 2 3 4
FR107
NO Lock
AUXOUT1
+12V
NO COM NC
BEEP GLED WD1 WD0 GND +12V
READER2
TX RX
IN GND
READER1
PC
IN GND
AUX2
LAN
GND
AUX1
IN
SD card
TX RX
485+ 485GND
GND 485485+
BUTTON1
5 6 7 8
LINK
Advanced Access Control
IN
SD card
+12V EXT
ON
1 2 3 4
ACT
GND IN GND
LAN
+12V
AUX2
SD card LAN
IN GND
AUX2
LAN
GND
AUX1
SD card
IN
ON
LINK
LINK IN
1 2 3 4 5 6
LINK
AUX1
3) When the Electrical Lock is connected to the Access Control System, you need to parallel one FR107 diode (equipped in the package) to prevent the self-inductance EMF affecting the system, do not reverse the polarities.
DIP switch
LED 1
2 3 4 5 Jumper terminal
Notes: 1) Internationally accepted RVSP(shielded twisted-pair) wires should be used for communication to effectively avoid interference. RS485 communication wires should be connected by means of bus cascade connection. 2)Considering stability of communication, it is recommended the length of RS485 bus is less than 600m 3) One RS485 BUS may hold 63 units of control panel, but it is not recommended to connect with more than 32 units access control panels.. 4)When the bus is longer than 300m, to enhance the stability of communication, it is necessary to keep place 8 of DIP switches of the first and the last control panel at “ON” status. As shown in the figure above, place 8 of the DIP switches of units 1# and 8# ON
is placed at "ON
“Wet mode” wiring diagram of lock connecting with external power supply.
1 2 3 4 5 6 7 8
" status.