Transcript
REV. E
DESCRIPTION
REVISIONS
REFER TO ECN
ECN
11825
DATE 7/2/13
APPROVED EHN
7.14 181.5
MAXIMUM CHARACTERISTICS
Application: Outdoor, Gigabit Power over Ethernet surge protector. The DC power terminal (+48Vdc or -48Vdc) is connected to the surge side of the shielded RJ45, power pins 1/2, 3/6 and return pins 4/5, 7/8, and provides a means to input or extract +/-48Vdc power. Electrical Performance: Connector Style (data): Shielded RJ45 Protected Pins: All 8 pins & DC pair Maximum Continuous Operating Voltage: +/-70 Vdc Maximum Data Range: 1000Base-T Typical Capacitance: 3pF Typical L-G DC Input: +/-48 Vdc & Return (Pins 1/2, 3/6 and 4/5, 7/8) DC Input Wire Gauge: 16-26 AWG Maximum Surge: 100 A; 10/1000 µs per BELLCORE 1089, L-G Maximum Let-Thru Voltage: <20V @ 100A, 10/1000us Maximum Operating DC Current: 2A @ 85°C Turn On: Surge Side: ±82Vdc L-G Mechanical: Max Dimensions: (H x W x D) in: 7.14 x 5.69 x 1.65 Weight: 0.85lbs
1.65 41.9
5.69 144.5 CUSTOMER APPROVAL: _______________________________________ ALL DIMENSIONS SHOWN ARE FOR REFERENCE ONLY.
Environmental: Operating/Storage temperature: -40 C to +85 C Humidity: 0 TO 95% (Condensing) NEMA 3R
UNLESS OTHERWISE SPECIFIED LEADING DIMENSIONS ARE INCHES DIMENSIONS IN [ ] ARE MILLIMETERS TOLERANCES: FRACTIONS=± ANGLES=±
RoHS Compliant.
1/32 .XX=± 1 ° .XXX=±
.01 .
DRAWN ENG APPD PRODUCT MGR MARKETING APPD
MATERIAL
NOTED . THESE COMMODITIES, TECHNOLOGY OR SOFTWARE WERE EXPORTED FROM THE UNITED STATES IN ACCORDANCE WITH THE EXPORT ADMINISTRATION REGULATIONS. DIVERSION CONTRARY TO U.S. LAW PROHIBITED. © 2013 Smiths Power. All rights reserved.
DATE: __________________
THIRD-ANGLE PROJECTION
PROJECT NO.
BGT
DATE 3/15/11
LC
4/8/11
SD
4/8/11
PB
4/8/11
DD78083
TITLE
SIZE
NOTICE: THE INFORMATION AND DESIGN IN THIS DOCUMENT IS THE PROPERTY OF TRANSTECTOR SYSTEMS. ALL SCALE RIGHTS RESERVED.
B
ALPU GbE PoE INJ
CUSTOMER SPECIFICATION PART NUMBER
CAGE
30992 1:2
PROD CAT
DST
DOCUMENT NAME
REV
E
1101-998 1101-998-C
SHEET
1
OF
1