Preview only show first 10 pages with watermark. For full document please download

Manual

   EMBED


Share

Transcript

2.4GHzWireless Digital Microscope Comprehensive Operating Instruction Contents 1 For your safety 2 2 Anyty Series Line up and Accessories 3 Manual of Anyty Series PC Model P1 How to charge Anyty Wireless Digital Microscope 5 P2 Requirement of using Attached Software(Anyty VIEW) 6 P3 Installation of Anyty VIEW(Windows7/Vista) 7 P4 Installation of Anyty VIEW(Windows8) 12 P5 Simple use of the product 13 P6 Turn the power on and Channel Harmonization 14 P7 About operation of Anyty Digital Microscope 15 P8 Capture with Anyty VIEW 16 P9 Edit images which have been photographed by Anyty VIEW 28 P10 Play movies which have been filmed by Anyty VIEW 30 P11 Spec 31 Manual of Anyty Series TV Model T1 How to charge Anyty Digital Microscope and LCD Monitor 32 T2 Switch on and Channel Harmonization 34 T3 Simple use of the product 37 T4 About operation of Anyty Digital Microscope 38 T5 Capturing still pictures 39 T6 Capturing movie 40 T7 Preview of images/movies 41 T8 Deletion of images/movies 43 T9 About all kinds of setting 44 T10 About all atteched accessory(TV connection・stand) 47 T11 Spec(LCD Monitor) 48 4 Common Fix 49 About the sign of magnification PLEASE NOTE: The signed Magnification is based on exact size of when using 15 inch monitor. Any using other size of monitor or specified monitors for TV model could lead to different magnification. 1 1 For your safety For safety use of the product, prohibition of using and cautions are written. To ensure customer’s safety, PLEASE read this carefully before using. Caution Contents of actions lead to danger to life or serious injury. Attention TV Model has two types of charging adaptors. PLEASE use them properly. DO NOT mix them up. Attention DO NOT leave or use the product under direct sunlight and circumstances of high temperature. Otherwise it would lead to dilation or explosion of the battery. If smoke or smell is emitted, PLEASE stop using the product immediately. DO NOT look straight at the light laze from the product. DO NOT look directly at LED light source. It could damage your Visual Acuity. AVOIDING touching with wet hands DO NOT use the product with wet hands or the product in wet conditions. It could lead to electric shock. Decommissioning prohibited DO NOT decommission or modify the product. It could lead to electric shock or fire hazard. DO NOT use Organic Solvent on Resin body PLEASE note that using of alcohol or thinner for cleaning is prohibited. DO NOT use supply unit in addition to specified supply unit. It has danger of causing fire hazard or electric shock. Caution Other contents that you should be careful about. Unplug the power cable from the Microscope, Monitor when the charging is complete. DO NOT insert fingers in lens part. In addition, DO NOT point strong light to lens part. Rechargeable batteries are In-built. PLEASE follow the instruction of disposal. 2 2 Anyty Series Line UP and Accessory This Comprehensive Operating Instruction is for 2.4GHz Wireless Microscope「Anyty」Series. PLESE NOTE: The combination of Accessory could be different due to the your demanded Model Contents of Accessories in different type of products mentioned below(To see all contents of every models, please go to next page) A. Common Accessories for all models ●Operating Instruction(This book) ●Dedicated Case B. Accessories in Microscope of magnification x 200 ●Model of magnification x 200 ●Three Lens covers (For x60 / 200) (For x80 / 150) (For x100) C. Accessories in Microscope of magnification x 600 ●Model of magnification x 600 ●Two Lens covers (For x500) (For x600) D. Accessories in PC Model ●USB Receiver ●miniUSB Cable ●Simple Scale ●Product Stand ● AC/USB Adaptor ●Microscope Charging Cable ●Holder ●Software CD E. Accessories in TV Model ●Dedicated Monitor ●Stand for Monitor ●AC/USB Transform Adaptor ●AC Charger for Monitor ●miniUSB Cable ●Microscope Charging Cable ●TV Cable 3 Summary of common contents in every type of products Contents and accessories in every Model are noted below. PLEASE check Alphabets in previous page if it contains the right accessories. No 1 2 3 4 5 6 7 8 Product 2.4GHz Wireless Digital Microscope Magnification x 200 PC Model 2.4GHz Wireless Digital Microscope Magnification x 200 TV Model 2.4GHz Wireless Digital Microscope Magnification x 600 PC Model 2.4GHz Wireless Digital Microscope Magnification x 600 TV Model 2.4GHz Wireless Digital Microscope Set of Magnification x 200 PC&TV Model 2.4GHz Wireless Digital Microscope Set of Magnification x 600 PC&TV Model 2.4GHz Wireless Digital Microscope Magnification of x 200/600 PCModel 2.4GHz Wireless Digital Microscope Magnification x 200/600 PC Model Model Contents 3R-WM401PC A、B、D 3R-WM401TV A、B、E 3R-WM601PC A、C、D 3R-WM601TV A、C、E 3R-WM401PCTV A、B、D、E 3R-WM601PCTV A、C、D、E 3R-WM461PC A、B、C、D 3R-WM461TV A、B、C、E 2.4GHz Wireless Digital Microscope 9 Full set of Magnification x 200/600 PC3R-WM461PCTV A、B、C、D、E &TV Model 10 11 12 13 2.4GHz Wireless Digital Microscope Microscope of Magnification x 200 2.4GHz Wireless Digital Microscope Microscope of Magnification x 600 2.4GHz Wireless Digital Microscope A Receiver for PC Model 2.4GHz Wireless Digital Microscope A Monitor for TV model 3R-WM401 A、B 3R-WM601 A、C 3R-WMSOFTSET A、D 3R-WMMOTV A、E Operation of PC Model → See page 5 Operation of TV Model → See page 32 4 P1 How to charge Anyty Wireless Digital Microscope Microscope itself is chargeable. Before start using it, please charge the battery of microscope. Connect charging cable (attached inside) to charging connector on Microscope. Then, connect to USB port on PC or AC/USB Transform Adaptor. During charging period, the dial switch will be shining (blue light). Charging period will be approximately 3 hours. It could last for 5 hours in full power condition. Attention USB Charging Cable is for Microscope ONLY. DO NOT use ANY other charging cable on it.. Charging Connector Charging Connector is on back of Microscope. Dial Switch Power switch is on side face of Microscope. Turn right until you hear the sound of ‘click’ and the power will be turned on. Turn left until the same sound is made. The power will be off. Dial Switch Dial Switch will be lighting up during charge or operation。Patterns of lighting up in each condition are noted below. Charging Blue flash Charging complete Blue light Low power Red light 5 P2 Requirements of using attached Software(Anyty VIEW) Installation of Anyty VIEW will be required in order to be able to use PC Model on PC. Requirements will be mentioned below. ※The software of this product is not officially compatible with Windows8 purchased in 2012. To understand the newest compatibility, please contact: [email protected] ★The minimum specs Compatible OS※ Windows7(32bit / 64bit) Newer than WindowsXPSP2、Vista (Only for 32 bit) CPU CPU above Pentium Ⅲ 600Mhz Optics Drive Essential Memory 256MB or more of Physical Memory Save Area 100MB or more HD space Connection Method USB1.1/2.0 Display Space 15 Inch(XGA)or more of display space Graphics Facility 16bit color or higher graphics facility Practical use authority Installation and using of the software may require ADM ★Recommended specs CPU Pentium 4 1.6Ghz or better CPU Memory 512MB or more memory space Save Area 10GB or more HD space Display Space 17 Inch(SXGA)or more display space Graphics Facility Higher than 16bit color, 64MB or more of Graphics Card 6 P3 Installation of Anyty VIEW(Windows7/Vista) ※The installation could be done irregular if antivirus software is active. PLEASE exit antivirus software for a while refers to its manual during installation. ※ DO NOT connect Receiver to PC until installation is complete. ※ Please press ‘Continue’ if User Account Control(UAC) is activated. ① Insert Software CD into CD-ROM. The option will be shown as below if auto play is activated. Press Autorun.exe to start installation. ※If ‘Auto play’ is not activated. Please double click ‘My computer’ and RIGHT click CD-ROM icon, choose ‘Open’. Then find ‘Autorun.exe’ and double click to start installation. 7 ② The Menu will be shown as below when set up program is activated. Choose ‘Install Software(32bit)’ or ‘Install Software(64bit)’ on the basis of your PC specs. ※Please see 49 page to confirm your PC spec(32bit or 64bit) ③ The image will be shown on screen as below. Please press ‘Next’ 8 ④ ‘License Agreement’ will be shown. To continue installation, please tick ‘I accept'. Then click ‘Next’. ⑤ You could choose which folder to save it at next screen. Normally, click ‘Next’ to start program installation. 9 ⑥ Press ‘Finish’ when screen shows as below. It is all complete about installation of Anyty VIEW. Move on to examination of Receiver. ⑦ Connect Receiver to USB port on PC with miniUSB cable. Windows will detect the device automatically. Installation will be done when the message shows as below. ※ The name will be shown in Device Manager as images shows as below ※ To confirm by Device Manager, please left click on ‘Start’ and right click on ‘Computer’. Then find ‘Manage’ and left click on it. 10 ※ During the Device installation, please press ‘Install this driver software anyway’ to continue installation. 11 P4 Installation of Anyty VIEW(Windows8) ※The software of this product is not officially compatible with Windows8 purchased in 2012. To understand the newest compatibility, please contact us at: [email protected] ※In case of using Windows8 32bit version to install, insert install CD into CD-ROM. Then click the icon of computer on Desktop so the explorer will be shown. Thirdly, open (click) CD-ROM icon and run ‘Autorun.exe’. In the follow-up processing, please go to page 7 of Installation of Windows7/Vista. During the Device installation, please press ‘Yes’ to continue installation 12 P5 Simple use of the product ※Detailed manual of step of use will be showing below ① Connect Receiver to PC and tune the ② channel ③ Install a lens cover and turn the power on. Launch software ‘Anyty VIEW’ ④ Adjust luminance Magnification dial. of As LED you and press shutter button, the image will be saved in the PC. 13 P6 1. Turn the power on and Channel Harmonization Connect specified Receiver to PC with miniUSB cable. Once they have been connected, please set the channel from one of ‘1, 2, 3, 4’ Switch of Channel (Channel of 1、2、3、4) 2. Then adjust the switch on Anyty Wireless Microscope as same number as on Receiver。 Switch of Channel (Channel of 1、2、3、4) 3. Once the channel has been tuned, please turn dial switch right on Anyty Wireless Microscope Sound of ‘click’ is the sign of power on. Dial switch ※ Dual-purpose switch to Adjust luminance of LED and power 14 P7 About operation of Anyty Microscope ※Magnification dial should be facing you when you use Microscope 1. Load the lens cover The product is monofocal. Lange from object to Microscope will be different according to different magnification you have selected. Figure of magnification is printed on attached lens cover. Please use switch to lens cover with the corresponding figure of magnification when you take picture. It will be the right focal length as the lens cover and object touch each other. Trimming could be done with Magnification dial. Magnification dial Lens dial 2. To shoot under untouched and unknown magnification condition, the lens cover could be removed from Microscope. In the condition of untouchable between object and lens cover, or in case of shooting without lens cover, you could turn magnification to desired figure first. Then adjust distance between object and Microscope. ※PLEASE DO NOT touch built- in LED and lens. Pull lens cover to direction of arrow to remove it. 15 P8 Capture with Anyty VIEW ●Launch Anyty VIEW software The icon of Anyty VIEW will be established in ‘Program’ and ‘Desktop’ ※ In some case, icon would not be established on desktop. Desktop icon Double click to launch Anyty VIEW.。 You are also able to open it from ‘Start’ → ‘(All)Program’→ ‘3R Anyty VIEW 40101’ Please left click ‘3R Anyty VIEW 40101’ to launch it ●Main Window Once the program is launched, the Main window will be shown. 16 ●About icons on Main Window The icons in the image of below will be shown at upper side of Window. To understand name and function of each icon, please look at images shown below ●Function of each icons Photographing still picture Filming/Stop Continuous shooting of still picture Attach to E-mail Save ●Thumbnail of image and movie Icon of summary of image/movie Data of image and movie will be shown as thumbnail on left side of main window. Click the icons shown above to switch between thumbnail of images and movies. Data of image/movie will be saved in ‘3R files’ in ‘My Document’ so you are able to browse those data through ‘Exploler’ 17 ●Condition of thumbnail The frames as shown below will be occurred according to its condition at the moment. Thumbnail of selected at the moment. ~ Pink and Green frame Saved thumbnail ~ Green frame at right down corner The images saved in another file through using ‘Save’ icon ~ No frame ●Taking still picture Three ways of taking still picture. ① Press icon on tool bar ② Press keyboard button F2 ③ Press round button on Microscope Image data will be saved in folder, ‘3R Files’ in ‘My Document’ as name of Still pic_year-month-day hour minute second_(magnification)_number.bmp Magnification will be the figure that you have entered in main window. See scale Magnification dial to enter magnification.(→page 23) 18 ●Film movies Two ways of film movies ① Press icon on tool bar ② Press keyboard button F3 The setting window as below will be showing through two steps above. Set each option and press ‘OK’. Filming will start. Frame Rate(1~30) To set how many images will be saved per second. Higher number will make quality of the movie higher but size of data and load will be larger too. Normally, please use it under default condition. (Reference Analogue TV: Approx 30 fps Movies on Mobile phone: 15~24fps) Time limit Check the box to set filming time (in seconds ) and stop filming automatically※ Click to start or stop filming manually. When stop filming, the data will be saved automatically. ※Little error could be possible depend on condition or codec Codec You are able to choose different kind of codec (External Software) of movie to watch by PC. You might need to install specific codec depend on your PC. Please go to ‘4 Common Fix(→page 49)’to see how to install the codec. 19 ●Continuous shooting of still picture You could use this function to shoot still pictures continually. to display window (Setting menu) as an image below. Press ‘Start’ to start photographing Click after finish setting each option. Start Time・・・Set start later year, month, day, hour ,minute, second by now Interval・・・Setting shooting time interval in seconds. Next shooting will be done in time you have set after current shooting. Capture・・・Set how many pictures you want to take and save. File size・・・It shows the size of pictures based on your settings. ●Attach to Email Select thumbnail of images or movies and press this icon, or choose 「Attach to email」 from Menu bar. After that, the defaults Email software in your PC will be opened automatically with selected data adjust. ●Saving Select thumbnail of images or movies and press . The window for saving will be shown so you could resave data in any file you want. Press same icon when you want to save edited data. 20 ●About options on Main bar ■File Contains the same functions of icons on the Main Window (Save edited data in any file you want in your PC, Delete chosen images/movies or all data). ■Settings You are able to change each setting or make it display scales. Two kinds of resolution of saved pics Changing options of display (see page 22) Mainly changes the measurement functions settings Shows scale and circle.etc on the screen (see page 22) Change the language of the software. ■Capture Contains the same functions of icons on the Main Window (Taking still picture or filming movie and taking Continuous picture) ■Help Display the software version and our website. 21 ●Settings of image quality You are able to set quality of Microscope in this option. Change resolution of the saving picture. Adjust Brightness of captured image Adjust Contrast of captured image Adjust Saturation of captured image Adjust Sharpness of captured image Adjust Hue of captured image ●Display cross line and others You are able to set cross line on screen during shooting. It is useful when you want to aim the place and check the time. You can find them in ‘Settings’ Cross line Display a cross line at the center of screen Scale Display scale horizontally and vertically. It will overlap cross line. Dial gauge will not change due to change of magnification. Circle Use center of screen as a baseline to display circle 22 ●Full Screen Mode Click Maximization icon to view ‘Anyty View’ in full screen. To terminate full screen mode, please press ’ESC’ button on keyboard. ●Input magnification. There is a blank for entering magnification at top of right side of the main window during shooting period. Please see magnification dial gauge and the number printed on lens cover to enter, the measuring function will calculate the data automatically based on figure in the blank. (go to page 26) See Magnification dial gauge and enter. ●Change of direction Click the icons on the menu bar to change screen direction. ■Flip horizontal Icons of changing direction ■Flip Vertical ●Color modification Click icons which have functions of Negative, Vampix and Color Incalidation. ■Negative ■Vampix ■Color Invalidation 23 Color Invalidation Icons (choose two) Negative and Vampix ●Measurement functions Icons at right side of menu bar are for measuring. Each icon has its specific measurement method. Icons of measurement ●Operation of Measurement functions(e.g. Linear size) ① Click the icon on menu bar. Measurement of Linear size 24 ② Next, please click two points of what you want to measure. For example, click bottom and top part of the ‘L’ when you want to measure height of it. Click twice at the point of red arrow ③ At last, click anywhere you want to display the value. It will be displayed Please click ‘Save’ icon to save the value you have measured if you want. Click once more and the measured value will be displayed 25 Attention ※ The figures are calculated based on shooting magnification at top right side of the Main window. If you want to obtain more accurate numerical value, please see page 26 or page 27 (Additions and Corrections). ※ You might need to click more than twice depend on some specific measurement. ●Additions and Corrections Use ‘Additions and Corrections’ to calculate more accurate value. Steps are shown below. ①First, capture attached simple scale ore micro meter with Microscope. Then, click the icon on top right side as picture shows below. Calibration ②Next, please click two side of the scale that already clear of size (same as calculate Linear size). Click two sides ③The window shows as below will be displayed. Please enter the size and click ‘OK’. 26 ④Value will be filled in left side of ‘magnification’. From then on, the measurement will be done based on the calibration value. ●Clear the measurement function If you want to renewal the measurement or delete it, please click the icon at right side of correction icon’▼’. Click ‘Undo’ to delete previous measurement. Also, click ‘Delete All’ to delete all value you have entered. ●Pen settings(Setting of measurement functions) Click ‘Setting’ in setting on menu bar or click setting in ▼ icon to display Pen setting menu. You are able to set font of letter (Linear size. etc). 27 P9 Use Anyty VIEW to edit captured still picture Click thumbnail of still picture to open editing window。 You are able to measure and input words here as you have done in capture screen. Open Open named picture which are captured by Anyty VIEW only. Save You are able to save the picture as another name after editing. Paint You are able to paint line and figure in picture. Measure Enter magnification to enable measurement and editing. ※Operation steps are same as in page 24 Pen setting You are able to change color of painting and line of measurement. ※Screen and control are same as manual on page 27 28 Text setting You are able to input text on picture. Please enter texts in black. Change font of texts ※ Font will be different between vertical writing and horizontal writing. Press ‘OK’ when finish entering Left click to insert text on part of images where you wish to put Undo Return to previous status during editing. Redo Redo of what you have done before ‘Undo’ Enter magnification at capture period. You must do this when you measure size. Calibration Use this to improve accuracy of measurement. ※To understand control step, please see page 26 29 P10 Playing captured movies with Anyty Double click the movies you have captured in main window to open movie player and start playing it. 30 P11 Spec Spec of 2.4GhzWireless microscope Anyty PC Model Image sensor 350 thousand pixel CMOS sensor Still picture size 720x480,640x480,320x240 Movie size 720x480,640x480,320x240(maximum 30fps) Light source 8 adjustable LED white light Wireless type 2.4Ghz wireless 4 channels(Transmitter/receiver) Transmission distance Approx 5m PC interface (receiver) USB 2.0/1.1 Magnification(x200) x10~200(15 inch LCD screen) Magnification(x600) x450~600(15 inch LCD screen) Power source Charging(Li-ON Battery) Full charge time Approx 3 hours Max working time Maximum 5 hours Life Approx 500 cycle Power consumption Maximum 0.75W Focus range x200 model: 8~300mm x600 model: Close-up photography only Body size 135mm (L)x36mm (R) 31 T1 Charging Anyty Microscope and LCD Monitor Before using Microscope, please charge battery of Microscope. Connect attached charging cable to charging connector on Microscope. Connect other side of cable to USB port on PC or AC/USB transform adaptor. During charging period, dial switch flashes blue Charging period will be approx 3 hours. Maximum 5 hours of working time in full power condition. Attention USB charging cable is specialized to Microscope. Please DO NOT use it for charging LCD monitor. It could be the cause of breakdown or heating. Charging connector Dial switch Turn it right until it sounds ’click’ and the power will be on. Charging Blue flash Charging complete Blue light Low power Red light 32 Next, please charge battery of monitor. Connect attached adaptor to the charging port on left side of the LCD Monitor, and then connect other side to household wall outlet. (100V) A part of monitor at left up side will light red during charging period. The red light will turn off when the charging is complete. Charging time will be about 3 hours. It lasts about maximum 2hours in full power condition. Attention AC adaptor is only for LCD Monitor. Please, DO NOT use it on Microscope. It could be the cause of breakdown or heating. During charge period Red light Charge complete Light off Press power button at top side of LCD Monitor to turn the power on. Light on top left side will be green and monitor will be turned on. Please press power button longer to turn the power of. 33 T2 Turn on the power and tuning radio channel Insert MicroSD card in to LCD Monitor. Confirm that the MicroSD card is inserted properly. Then choose one of four channels. After tuning, turn the dial switch right on the Microscope until it sounds ‘click’ to turn on the power. Dial switch ※ Dual-purpose switch to Adjust luminance of LED and power Then turn of the power of the LCD Monitor. 34 The monitor will shows screen as described below Channel will be shown on top right side of the screen. Radio Channel Press ▼ button to do the tuning in case of mismatching channel. ▼button Setting is complete if the picture is displayed. 35 ■ Language setting ※This manual is based on English. 【Steps】 ① Press button(≡) for about 2 seconds and release in condition of power on. ② Setting menu will be displayed Select ‘SYSTEM SETTING’ with ▲, ▼ button and press ‘OK’ to confirm. ③Each setting will be displayed Select ‘Language’ with ‘▲’, ‘▼’ button and press ‘OK’ to confirm. ④The language will be set Select ‘English’ with ‘▲’, ‘▼’ button and press ‘OK’ to confirm ⑤Press(≡)button 3 times to back to main screen That is all about language setting. 36 T3 Simple use of the product ※See more details about operation steps. ① Turn the both power of Microscope and ② LCD monitor on. ③ Press ‘▲’ button on the monitor to Load lens cover and adjust magnification and focal point. ④ Press ‘OK’ button to save the data. select image/movie to capture. 37 T4 About operation of Anyty Microscope ※Shutter button would not be used in TV model ※Magnification dial should be facing you when you use Microscope 1. Load the lens cover The product is monofocal. Lange from object to Microscope will be different according to different magnification you have selected. Figure of magnification is printed on attached lens cover. Please use switch to lens cover with the corresponding figure of magnification when you take picture. It will be the right focal length as the lens cover and object touch each other. Trimming could be done with Magnification dial. Magnification dial Lens dial 2. To shoot under untouched and unknown magnification condition, the lens cover could be removed from Microscope. In the condition of untouchable between object and lens cover, or in case of shooting without lens cover, you could turn magnification to desired figure first. Then adjust distance between object and Microscope. ※PLEASE DO NOT touch built- in LED and lens. Pull lens cover to direction of arrow to remove it 38 T5 Capture the still picture The images captured by Anyty Wireless Microscope will be saved in SD card in the LCD screen. In order to capture still pictures, please turn on the power of LCD Monitor first and press ‘▲’ button. It will be still picture mode. ・ Saving still picture Residual amount of a battery Icon of Channel still picture mode Icon of Micro SD card Savable number of pictures Current Time Time stamp Press ‘OK’ button at left side of the LCD monitor in Saving Still Picture Mode to save current screen. The icon of MicroSD will be marked ‘F’ if the SD card is full. 39 T6 Capture movie The Initial State (first time turn the power on) of the LCD Monitor will be Movie capture mode. Or press ‘▲’ at Still picture mode. It will be switched to Movie capture mode ・ Saving movie mode Residual amount of a batter Icon of Movie mode Icon of Micro SD card Possible recording time or recording time Current Time Time stamp Press ‘Ok’ button at left side of the LCD monitor in Movie capture mode and recording will be starting. During capturing period, a round icon at top of the screen will flash. Capturing time will be shown at bottom right side of the screen. Press ‘OK’ again to stop recording. The icon of MicroSD will be marked ‘F’ if the SD card is full 40 T7 Preview (Images/Movies) Press ‘≡’ button at right side of the LCD monitor to activate Preview of Images/Movies Mode. Index of folders will be shown. They are separated by different capturing date. Press ‘▲’, ‘▼’ button to select and ‘OK’ to confirm. Then, the index of selected file will be shown. Press ‘▲’, ‘▼’ to choose Data of what you want to view and press ‘OK’ to confirm. Movie data Image data ※ Difference between Image/Movie data: Data with double quotation mark ・・・ Image data Data with no quotation mark ・・・ Movie data Preview images Press ‘OK’ to display the image on screen. Press ‘OK’ again to back to previous screen. 41 Preview of movies Press ‘OK’ to play the movie. Halt : Press ‘OK’ when the movie is playing. Forwarding : Press ‘▲’ when the movie is playing Rewind : Press ‘▼’ when the movie is playing End : Press ‘≡’ to end 42 T8 Delete images/movies Select the file that you want to delete with ‘▲’, ‘▼’ button. Then, press ‘≡’ button for 2 seconds. It will ask you if you confirm. Select ‘Yes’ and press ‘OK’ to delete the file. 43 T9 About each settings You are able to change each setting of LCD Monitor. Turn on the LCD monitor and Press ‘≡’ button for 2 seconds Setting menu will be showing up as below. Press ‘▲’, ‘▼’ button to select and press ‘OK’ to confirm. ● Language setting ⇒Please go to page 36 ● Video type setting ※ Normally, unnecessary to change from NTSC to another. ① Select ‘SYSTEM SETTING’ in setting menu. ② Select ‘Video System’ ③ Select one from ‘NTSC’ and ‘PAL’ and press ‘OK’ to confirm ● Formatting ※ All data in SD card will be deleted after formatting ① Select ‘SYSTEM SETTING’ in setting menu. ② Select ‘Format’. ③ Choose ‘Yes’ to format MicroSD card. ● Initialize the config ※ All setting will be reset after initializing the config. ① Select ‘SYSTEM SETTING’ in setting menu. ② Choose ‘Default Setup’. ③ Select ‘Yes’ to initialize the config. 44 ● Version information Confirm a version of the internal software. ① Select ‘SYSTEM SETTING’ in setting menu. ② Select ‘Version’. ③ Current software version will be displayed. ● Frame rate Change the frame rate of the movie ① Select ‘RECORDER SETTING’ in setting menu. ② Select ‘Frame Rate’. ③ You are able to change frame rate from 10 to 30fps. ● Time stamp Changing having time stamp or not ① Select ‘RECORDER SETTING’ in setting menu. ② Select ‘Time Stamp’. ③ Select one from ‘ON’, ‘OFF’ and press ‘OK’ to confirm. ● Capturing type You are also able to switch between still/video from setting ① Select ‘RECORDER SETTING’ from setting menu. ② Select ‘Recording Type’. ③ Select one from ‘Still’, ‘Video’ and press ‘OK’ to confirm. ● Preview You are also able to find preview function from setting. ① Select ‘EVENT PLAYBACK’ from setting menu. ② You are able to preview still/video. 45 ● Time setting Change the setting of the internal date and time ① Select ‘Date / Time’ in setting menu ② Set ‘Year-month-day’ and ‘Hours’ Use ‘Up’ and ‘Down’ button to change value and move to the next item by the ‘Confirm’ button ③ Push the menu button if you have set all values and finish. 46 T10 About accessories (TV connection・stand) ● Loading of Magnet stand for LCD monitor. The LCD Monitor could not only be held by hand to use it, but also can be fixed with a magnet stand. Attach stand to LCD monitor to put it on the desk or fix it with magnet power. Caution Please be careful not to fix it to device which could be affected by its magnetic force. ● TV output function It is able to display video in LCD Monitor on TV. Please connect picture input of TV to the picture output of the LCD monitor with an attached video cable. A picture will be output to TV without a screen being displayed when you switch on the LCD monitor ● Use USB cable to connect(Optional) Please use miniUSB cable (sold at market) to connect with PC when you want to view data on PC. Connect LCD Monitor and PC with miniUSB cable and turn on the monitor. You are able view the data of the card of the MicroSD slot with a PC as a removable disk. ● The animation will be saved in XviD Codec. Please set up the animation software corresponding to the XviD form. 47 T11 Spec(LCD Monitor) 2.4Ghz Wireless Microscope Anyty TV Model Spec of the LCD Monitor ※Please refer to the detail of the specifications of the PC model for the specifications of the main body of Anyty microscope ※The magnification will be based on the size of images which are displayed on 15 inches monitor. The magnification of when it is displayed it with a attached monitor of the TV model will be different. Thank you for your understanding beforehand. LCD 3.5 inches TFT LC Resolution 320x240 Video format PAL/NTSC Frequency 2414MHz、2432MHz、2450MHz、2468MHz Power supply 5VDC Consumption current(max)500mA Charging time About 3 hours Working time Maximum 2 hours Resolution of still/video 640x480 Movement size 27MB/min Frame rate Maximum 30fps Output signal level 0.91.3VP-P@75ohm Receiver sensitivity 《-85dbm External form 100x75x25mm Weight 140g Workable temp -10℃~50℃ Workable humidity 15~85%RH 48 4 A Common Fix If Anity VIEW device or Anyty VIEW software were working OK but suddenly stops working properly, Please try the following. B 1 Close Anyty VIEW software and unplug receiver. 2 After waiting for 3 minutes, plug on receiver. 3 Power on the Microscope and re-open Anyty VIEW program. After PC resume from standby or hibernate Anyty VIEW might not work properly, please close it and re-open to try. C If it does not work even if you connect a microscope and re-start Anyty VIEW, please uninstall Anyty VIEW once, and install Anyty VIEW once again and try. D When there is wireless LAN or Bluetooth in the environment using the microscope, it may have an influence on operation of the microscope. E When you could not operate an LCD monitor in TV model, please push the reset button of the backside with a former thin thing and switch it on again F Please try the following operation to confirm the number of the bits of the system by Windows7 and Vista Please right click the ‘Computer’ and click ‘Property’ Please look at ‘System Option’ in ‘System’. G Please follow the steps to install codec for saving animation. Insert a software CD into CD-ROM of the PC and open ‘My Computer’ of the start button. Next, right click the CD-ROM and choose ‘Open’. Then find ‘Autorun.exe’ to activate install program. Install the software according to the instructions of the screen. After installation is complete, ‘MJPG_MainConcept Video V3.2.4’ will be available in the column of ‘codec’. 49 Manufactured and sold by 3R SYSTEMS CORP. HQ No.5-8-11 Naka, Hakata-ku, Fukuoka City, Japan +81-92-441-4056 Official website 50 +81-92-441-4077