Preview only show first 10 pages with watermark. For full document please download

Manual 8670689

   EMBED


Share

Transcript

D EH U M R EL AY 14 10 5 4 PURPLE 39 5 6 GREEN 38 55 C 460V D/YO Purple/White W1/E D/YO Purple/White W1/E Red/Yellow Y2 Purple A Brown/White Red/Yellow G Orange Y2 Purple Y1 Yellow A Brown/White O/B Blue W2 Brown G Orange Y1 Yellow O/B Blue W2 Brown R Red/White C Black/White L Pink PLUG #2 1 2 3 4 5 6 7 8 9 10 11 12 R Red/White C Black/White L Pink PLUG #2 1 2 3 4 5 6 7 8 9 10 11 12 Temp. and Humidity Controller Part #8403-060 Red 24VAC Black Analog Out "D" THERMOSTAT OPTION Yellow Brown Red Black Yellow Brown Orange Green PLUG #1 1 2 3 4 5 6 Orange Green 4115-100 A CO2 Controller Part #8403-056 "H" THERMOSTAT OPTION 4115-101 A 2 3 12 11 10 9 8 7 6 5 4 3 12 PIN VENT PLUG 2 1 YELLOW 38 C LPC LPC 19 4 5 3 2 1 BLACK/ WHITE 39 45 35 20 35 36 36 1 2 3 BLUE BLACK/WHITE BLUE PURPLE 1 High Speed Solenoid BLACK/WHITE BLUE/WHITE BLUE/BLACK RED 48 27 REMOVE JUMPER WHEN CS2000 ENERGY MONITOR IS INSTALLED Reversing Valve L2 REMOVE WIRE FROM TERMINAL Y2 AND TAPE OFF WHEN LOWER FULL LOAD CFM DESIRED Three way Valve STEPDOWN TRANSFORMER CLASS CC FUSE BLACK L3 H i Pre ssu re C o n tro l YELLOW L o w Pre ssu re C o n tro l L o w Pre ssu re C o n tro l Compressor 4113-301 A 99 NO ERV 3.2 3.2 3.2 5 Step Down Transformer 53 L1 W / ERV 5 5 7 7 ALR 1 OPTIONAL 3 PIN PLUG FOR ERV 27 FOR ANTIFREEZE LOOP APPLICATIONS, CHANGE LOW PRESSURE SWITCH TO YELLOW LEADS ON YELLOW WIRES COMING OFF OF COMPRESSOR CONTROL MODULE "LPC" TERMINALS MODEL QW2S QW3S QW4S QW5S CC Y 39 Compressor Contactor 27 18 Check Light BLACK BLACK/WHITE 460 VOLT PACKAGE UNIT DIAGRAM 1 T3 BLACK 32 BLACK/WHITE Temp. and Humidity Controller Part #8403-060 T2 BLACK 45 RED 39 T1 24 HPC 33 Transformer Purple/White L3 Fuse Block COM L2 38 31 RED 15 L1 R 48 27 GREEN BLACK/WHITE 4115-102 A RED 37 Orange Green Comp. Control Module 43 YELLOW R 34 YELLOW 54 42 YELLOW BLACK RED/ WHITE 38 ORANGE RED/WHITE "X" THERMOSTAT OPTION BLACK GREEN PINK RED/WHITE BLACK/WHITE BROWN/WHITE BROWN BLUE RED/ WHITE BROWN 6 PIN CO2 PLUG 27 41 PINK 44 YELLOW/RED 53 RED/WHITE 33 L2 L3 RED BLACK BLACK 12 LOW VOLTAGE STRIP 2 YELLOW 4 Brown BLACK/WHITE 3 Yellow RED/WHITE 2 Black 1 Red Black Yellow Brown Orange Green 40 C Phase Monitor L1 BLACK/WHITE 10 PINK 1 Y Yout 21 Ground Terminal 4 YELLOW 10 3 34 10 BLUE BROWN RED/WHITE 10 10 RED/WHITE Red GRAY YELLOW ORANGE PURPLE BLUE/BLACK 10 24VAC 30 10 PURPLE 53 BLUE RED/WHITE BLACK/WHITE BLUE Terminal Strip CO2 Controller Part #8403-056 Analog Out BLUE BROWN YELLOW Rotary Disconnect 27 RED Pink BLUE ORANGE YELLOW YELLOW 5 YELLOW 10 RED L D/YO BROWN/WHITE 50 YELLOW L O1 Y Y1 C 9 10 11 12 C Black/White BROWN/WHITE 46 Term. Block RED 8 C RED/YELLOW RED/YELLOW PURPLE PURPLE RED Red/White BLACK 29 YELLOW/BROWN Brown L1 L2 L3 RED 28 RED RED GREEN R 7 W2 R 5 6 W2 3 55 RED Blue ORANGE 54 BROWN/WHITE RED O 5 YELLOW O/B 4 Yellow 3 Y1 53 PURPLE/WHITE 2 Y1 10 460-60-3 POWER SOURCE 5 PIN PLUG FOR INDOOR BLOWER MOTOR 4 BLACK BLACK 12 PIN PLUG FOR THERMOSTAT 10 3 PINK Orange RED/WHITE Brown/White 11 2 10 YELLOW A G YELLOW YELLOW A G 52 51 1 Purple Terminal Block #1 ("A" Ctrl. Opt. Only) BROWN/WHITE C Red/Yellow Y2 O1 Y Y1 C PURPLE NC E Y2 2 BROWN NO C W1/E BLACK/WHITE NC PWR BLACK/WHITE BLACK/WHITE NO HVAC 9 13 BLACK/WIHTE AREA OCCUPIED Low Voltage Terminal Strip 1 10 6 YELLOW Optional CS2000A Energy Monitor (Use With "A" Thermostat Only) FREEZE THRMOSTAT RED/WHITE DEHUM. CONTROL 49 Temp. and Humidity Controller Part #8403-060 14 12 15 3 BLACK BLACK/WHITE 16 PIN PLUG FOR INDOOR BLOWER MOTOR 10 BLACK Wire Identification numbers for Bard use only. ! WARNING USE COPPER CONDUCTORS ONLY SUITABLE FOR AT LEAST 75° C. Factory Field Optional ! DANGER *ELECTRICAL SHOCK HAZARD *DISCONNECT POWER BEFORE SERVICING. High Voltage Low Voltage COMPOSITE WIRING DIAGRAM 460/60-3 Bard Mfg. Co. Bryan, Ohio 4113C301 A