Transcript
QUICKSTART “BASIC” GUIDELINES FOR MODEL 6003 - FOR GATES UP TO 10 FEET, 300LBS AND “OPENING TO THE INSIDE” Mounting System and Adjusting Open/Close Position Gate Hinge Pivot Point
Front Bracket Pivot Point
Model 6003 is intended for installation only on swing gates used for vehicles. Pedestrians must be supplied with a separate access opening. 120 Glasgow Avenue Inglewood, California 90301
For safety and installation instructions, please refer to the owner’s manual.
Rear Bracket Pivot Point
U.S.A.
40.5” Fixed Position
Board Adjustments
Manual Key Release
Front Bracket
SW1 1. Reverses direction primary arm opens.
Rear Bracket (Adjustable, See Manual)
Closed Position
A
CLOSE
Note: This illustration shows NO gate hinge inset. If gate hinge is inset on wall, refer to manual for rear bracket configurations (Page 12).
7” OPEN
7”
90° H KEY SWITCH BUTTON: Cycles operator when pressed. I RESET BUTTON: Resets circuit board.
Limit Sensors Slow Down
to a
dju
Clo
se
Un scr ew 4
st l
imi
Limitt
t se
nso
r.
Se
J Circuit board power
nso
r
scr
ew
s to
ove
en
cov
er.
Open to the Inside Position
Loop Detectors 9410
C
A
Se
nso
r
Radio Receiver D Not included - Refer to a specific Radio
B
Do not install the actuator arm in fully extended (Bottomed out) position. This will damage the arm, refer to manual page 12 for more information.
Battery Connection CAUTION
1 2 3 4 5 6 7
G
J
E Do not connect the battery to the circuit
D
board until power is needed to test the actuator arm.
AC
H Coaxial Cable Antenna (Not Supplied)
4302
Power Switch
115 VAC Connection
F 9 10 11 12 13 14 15 16 17 18 19 20
N.O.
7 8
Com
4 Open Input 5 Open Input
6
Mounting Hole
Power
Actuator Cable Coaxial Cable Antenna (Not Supplied)
G Actuator Cable Circuit Board Connections
Copyright 2008 DoorKing, Inc. All rights reserved.
1. Brown 2. Blue 3. Orange 4. Red 5. Yellow 6. Green 7. Green/White
Conduit
C
RED
Com Relay 24V
5
RED 24V
2 3 4
BLK 115V WHT
1
BOX MUST BE DANGER CONTROL PROPERLY GROUNDED!! F HIGH VOLTAGE!
Actuator Cable Loops
Receiver Manual (available from www.dkaccess.com) for more information on radio receivers and antenna installation.
E
Securely mount control box near the actuator arm with appropriate hardware (not supplied).
A support bar must be installed the entire length of the gate to support the pickets.
and Loop Information Manual (available from www.dkaccess.com) for more information on loops and loop detectors.
I
Control Box
Actuator arm and brackets MUST be level!
C Not included - Refer to the Owner’s manual
9409
C
must be on to adjust limit sensors, LEDs will light.
Op
rem
Auto Close Timer When SW1, switch 4 is turned ON, automatic timer can be set from 0-23 0 23 seconds to automatically close gate.
Mounting Holes
12 V 3 Amp/Hr Battery
nut
12 V 3 Amp/Hr Battery
Loo sen
B
2. Reverses direction secondary arm opens. 3. OFF 4. Auto Close Timer. 5. OFF 6. OFF 7. OFF 8. OFF
Alarm Reset
Chassis Ground
Loop Wires Tip: Do not drill any extra holes in the control box. Components must stay dry.
Tip: It is recommended that a surge suppressor be installed on the high voltage power lines. Note: To turn-off ALL power to the operator, the AC power switch must be turned off and the battery plug must be disconnected from the circuit board. High Voltage Conduit Tip: Never run high voltage and low voltage wires in the same conduit. Keep them in separate conduits. 6003-066-G-5-08