Transcript
Shenzhen Sodimax Technology Co,.Ltd
Manual for The Third Generation of Passenger Video counter system This is pure counter system in neutral package. Please follow the instruction below for correct connection, installation and adjustment. The picture below shows the family of pure counter system.
1.Parameter 1.1 Counting camera
Image Sensor:1/3 SONY CCD TV System: PAL/NTSC TV Lines:700TVL Image Output:Synchronous sampling output Lens’ Spacing:5MM Len:960*576 Pixel,3.6 mm (2.8mm/3.6mm/4mm/6mm Optional) Viewing Angle:55 degree Installation height Range:2.1M~2.3M(3.6MM len), 1.9M~2.1M(2.8MM len), 2.3M~2.5M(4MM len) Detecting Door Width Range:0.4M~1.2M White Balance:Auto Shutter:1/50-1/80000(s) 1/60-1/80000(s) Frame rate:25 FTPS Video Output Interface:Composite video output, 75Ω 1Vp-p Aviation
Shenzhen Sodimax Technology Co,.Ltd Gain:Auto SNR:>48db Power Supply:DC12 V Power:≤1W Working Temperature:-30~+55℃ Relative Humidity:10%~90% Not condensed Cooling: no active cooling, passive structure with heat dissipation Product Size:155(L)*50(W)*55(H)MM Weight:0.32KG 1.2 Counter Main Unit
System: Linux CPU: TMS320DM6446 Operation Interface: OSD with mouse and remote control Video Counting input: Max 2 channels Video Counting output: 1 channel Accuracy: 95% up operating voltage: DC 8—36V Operating power: ≤4W Operating temperature: -30°C -- +80°C Operating humidity: 10% -- 95% USB port: Standard 2.0 Counting input port: Aviation 1.3 Door Sensor
Shenzhen Sodimax Technology Co,.Ltd
Contact Way:Connected when touch, disconnected when separate Max Power:10W Min Switch Voltage:100VDC Avalenche Voltage:200VDC Max Switch Current:0.5A Max Load Current:1A Max Contact Resistance:100mΩ Min Insulation Resistance:10~10Ω Moving Time:0.4ms Bounce Time:0.3ms Release Time:0.05ms Max Working Frequency:5000±400HZ Sensitivity:07-10AT Minimum Reset Index:5AT Max Contact Capacity:0.3pF Housing Material:Zinc Alloy Product Color: Gray Working Temperature:-30℃~80℃ Working Relative Humidity:≤95%(40℃) Sense Magnetic /Release Distance:35-45MM 1.4 Alarm Extension Cable
AL1—AL8:alarm input RX/TX:RS232 port 485A/485B:485 port 12V:12V 500mA power output out1/out2 :2 channel alarm output,Can activate the external two independent relay.
Shenzhen Sodimax Technology Co,.Ltd
2. Preparation and Installation 2.1 Prepare installation tool, screws, 2G Sim card(for GPRS Counter only), Computer with RJ45 port, and 1.5 meter internet cable. 2.2 Find suitable place on vehicle to install the mainframe(counter). 2.3 Find suitable place on vehicle to install the counting camera. 2.4 Find suitable point on vehicle to install the door sensor. 2.5 Connect the power cable according to requirement. (Refer to below connection ways) 2.6 Connect the counting camera cable. 2.7 Connect the door sensor cable. 2.8 After finishing the above steps, connect the mainframe to computer with internet cable. Then power up counter system and start to do setting on computer.
3.Installation 3.1 Power connection way There are 2 ways: a.ACC ignition way b.24 hours Powering way. Please double check the below pictures.
Shenzhen Sodimax Technology Co,.Ltd
3.2 Counting camera connection
connect “CAM1” to “AV1” ; connect “CAM2” to “AV2” ; connect “CAM3” to “AV3” ; connect “CAM4” to “AV4” ; Important Notice: Please Do not mix the serial of the connection, must coincide with the above serial number. 3.3. Insert 2G Sim card Use the screwdriver to open the screws onto both panels. Then the top part can be removed and can insert Sim
Shenzhen Sodimax Technology Co,.Ltd card. Finally don’t forget to screw up well.
3.4 Connection way for door sensor Find out the Alarm Extension Cable from the packaging box and focus on AL1 and AL2 white color wire. AL1 is for counting camera No.1. AL2 is for counting camera No.2. AL1 and AL2 are for signal connection. Find out the +12 V wire from the cable harness and connect to counting camera.
Shenzhen Sodimax Technology Co,.Ltd
Door Sensor Installation Reference
Close status
Open status
RX/TX :Baud Rate is 9600,by this port, our device could exchange the data with 3-rd party device, and send out the data to 3rd platform( please check serial port protocol file for more details), this pin will be only used when you need to integrate our deivce with yours.
3.5. Install counting camera on top of the door Find the suitable point on top of the door 3.5.1 If the bus has 2 doors, then use 2 counting cameras. If one door please only connect counting camera No.1. 3.5.2 Vertical principle. It requires to face the counting camera vertical toward the ground. Use the bracket to adjust until it is vertical. The minimum angle for each single adjustment is 2.5 degree for the easiest adjustment purpose.
3.5.3 There are 4 holes on the back of the counting camera for easy fix purse by screw. M2.5 X 5 screw is recommended. This design is for easy fixing by means of other tools such as normal camera bracket, customized boom etc.
Shenzhen Sodimax Technology Co,.Ltd 3.5.4 Make sure the counting camera is fixed on the center of the top with range 220 centimeter (minimum) from top to pedal. 3.5.5 For good performance, the lens should be selected according to target vehicle. Firm and stable feature are high demanded for the camera installation.
.
4.Parameter Configuration
Use computer to run this application ------
Shenzhen Sodimax Technology Co,.Ltd
4.1 Input IP 192.168.0.192. Input port 6008 and press Connect button. 4.2 Press Parameter Setting (below picture) to do setting for door sensor. 4.3 Check the door power output, if more than 5 volt, then set it High Level. (below picture can be example) 4.4 Finally press Set device parameter button to save the setting.
Here is the example for low level.
Shenzhen Sodimax Technology Co,.Ltd If the door power output is less than 5 volt after checking, then it is low level. Set up time zones,delay shutdown ,etc as below:
4.5 2G Sim card setting This is GSM card solution(For GPRS Counter only). Find out the APN, User name and Password for this 2G Sim card by Google, Telephone or other ways. Input the correct information. Below picture is one good example. After setting please press Set Device Parameter button to save setting.
Shenzhen Sodimax Technology Co,.Ltd
4.6 THE MOST IMPORTANT STEP The most important step is to save the image of each counting channel. 4.6.1 Please press Refresh Image button before starting to test the accuracy. 4.6.2 After pressing Save Image button the accuracy test can be started. 4.6.3 The tip is to make sure No block and no other stuffs before pressing the Refresh Image button. 4.6.4 If the environment has no change, no need to press Refresh button anymore after setting, until there are new changes. For example, the owner of the bus fleet wants to add one fixing junk bin inside the counting range.
Shenzhen Sodimax Technology Co,.Ltd
4.6.5 Make sure the CORRECT connection for Channel 1 and Cam 1. The same as to Channel 2, 3, 4 and Cam 2, 3, 4. Make sure no wrong connection. Here is one good example to quickly test whether it is correct. Example: Stand under the counting camera Channel 1 and Channel 2. Then press the Refresh Image button to see whether there is a block(caused by the head of testing person). If yes, then correct. Obviously Channel 2 is correct. Below picture is good example. 4.6.6 Finally make sure the Camera parameter sticker matches the same number showed on setting.
Shenzhen Sodimax Technology Co,.Ltd
Shenzhen Sodimax Technology Co,.Ltd
4.7. server IP ,server port,device ID setting
Notice:
Shenzhen Sodimax Technology Co,.Ltd
Please save background after installation, check videos and make sure if the camera is not shielded by wall, otherwise the counting is not correctly. Please save background when no passenger passing
Check if the installation height is appropriate: When a person stand under the camera, refresh the image and check if it can detect a target block as normal as shown below (see if the lowest ladder and the highest ladder can detect the target block):
Below picture channel1 background is with error, the possible reason is that wrong connection of the cameras(Left or right or camera parameters are not corresponding)
To check if the cameras’ connection is wrong: When a person stand under the camera,refresh the image and
Shenzhen Sodimax Technology Co,.Ltd check if it can detect a target block. See below picture, Channel1 (top part )is not with any target block, it means the cameras’ connection is wrongly made. Channel2(bottom part) is with target block after refreshing, it means the connection is correct.