Preview only show first 10 pages with watermark. For full document please download

Manual Of Barrier (curtain) Sensor

   EMBED


Share

Transcript

Manual of Barrier (Curtain) Sensor Manual of Barrier (Curtain) Sensor BS-200RC / BS-400RC / BS-600RC / BS-800RC BS-200RC: 2 Beams - 57 cm long. BS- X 00RC- Y BS-400RC: 4 Beams - 105 cm long. X =2 or 4 or 6 or 8 beams BS-600RC: 6 Beams - 153 cm long. Y =B or W Standard Installation: BS-800RC: 8 Beams - 201 cm long. SCS 2 SCS 1 Mounting Bracket 8 meter B: Black finish housing W: White finish housing Applications: Indoor / Outdoor perimeter security system Window, Door. When the mounting space is limited WALL Internal / External protection / Terrace / Sliding door WALL WALL Aluminum housing / PC Resin anti-UV cover / ABS Internal View: ABS-Side Upper Cap PC Resin Cover Tamper Switch Terminal Block (Optional) Aluminum Housing ABS-Side Bottom Casing Power LED Indicator (Green) VR1: For tx power adjustment VR1 Tx Beam alignment LED Indicator (Red) SW1Power LED Indicator Response Time Slide Switch (Green) JP1 JP2 Buzzer Rx JP1: Buzzer alarm(for beam alignment) Remove JP1: cancel the function after beam aligned properly JP2 Jumper closed: 1 beam broken alarm (2 sec.) function existed. JP2 Jumper opened: 1 beam broken alarm (2 sec.) function removed. Sensing range V.S. Sunlight Sunlight(Lux) < 30,000 < 40,000 < 50,000 < 60,000 < 70,000 < 80,000 Terminal block connection. side cap. Alarm: Break one or two adjacent beams. Anti-tamper circuit triggers alarm if power is cut or Tx power adjustment: By VR1(ON Tx's side cap). end cap is removed. Sensing range:8 meters (26 ft.) -- outdoor Slim aluminum housing, anti high-low temperature / Rubber ring Mounting Bracket Sensing Range 8meters 7meters 6meters 5meters 4meters 3meters SCS SCS Features: 16 meters (52 ft.) -- indoor Max. fog / rains. N.O./N.C./Common relay output. 2 or 4 / 6 / 8 separate photoelectric beam sensors. Mounting hardware included. Programmable trigger on simultaneous breaking of No synchronizing wires required. any single / 2 adjacent beams or 2 adjacent beams Led alignment indicator. broken only -- selected by JP2 on Rx's side cap Tamper switch. Specifications: Sensing range 8 meters (26 feet) max.-outdoor / 16 meters (52 feet) max.-indoor Input Voltage 10-30VDC Detection method Break one beam or two adjacent beams (1) 1 beam: 2 seconds alarm (2) 2 adjacent beams: immediately ***1 beam broken alarm trigger function can be removed; See (JP2) which located at Rx's side cap; (JP2) Jumper closed: 1 beam broken alarm (2 sec.) function existed. (JP2) Jumper opened: 1 beam broken alarm (2 sec.) function removed. Signal output Normal open / Normal close / Common relay output Response Time (Rx) 50/100/150/200 ms (selectable - by SW1 slide switch-Rx) 1A/120VAC ; 1A/24VDC Contact rating Tx Power Adjustment (by VR1) (a) when turn clockwise: become stronger (b) when turn counter-clockwise: become normal Wiring Connection Terminal block (See page 4) Power Led indicator Green Led (On both Tx/Rx unit) Led indicator for Beam alignment Red Led (On Rx unit) On : when beam is broken ; Off : when beam is aligned properly On : powered Off : no power (a)On : when sensor is connected with DC power & before beam Buzzer Alarm alignment is done. (for beam alignment) (b)Off : when beam aligned properly ; automatically. Black jumper1(JP1)(ON Rx)unit ***This function can be cancelled by JP1 removed*** P4 Tamper Switch 4 pcs/each set ; 2 on both sides of Tx/2 on both side of Rx Operating Temp -45 Dimensions Humidity W: 35 mm / H: 30 mm / L: see following 70% ~55 (-49 ~131 ) P1 Manual of Barrier (Curtain) Sensor Manual of Barrier (Curtain) Sensor Consumption current VR1 (On Tx Side Cap) Response Time One beam broken continued 2 senconds alarm triggered Cancelled. ("JP2" jumper opened) S1 Beam Broken BS-800RC J2 VR1 Tx Rx Tx Rx Tx Rx Tx Rx 45mA 32mA 55mA 35mA 65mA 38mA 75mA 42mA Tx Rx Tx Rx Tx Rx Tx Rx 45mA 40mA 55mA 43mA 65mA 45mA 75mA 48mA Broken one beam Response time: 2 sec pb Broken two adjacent beam Response time: 0.5 sec ("JP2" jumper closed) Conditions B Beam Aligned Beam Broken BS-200RC BS-400RC BS-600RC SW1 SW1 SW1 SW1 ON ON ON ON VR1 Typical Installations 1 2 1 2 50ms 1 2 100ms 1 2 150ms 1 200ms Windows (Internal / External) RX Length TX Side View TX Item 35mm (Width) Correct RX 2 RX TX Door Gate Length Top View Installation Notes TX 3 2 Dimensions 1 Strong BS-800RC Tx Rx Tx Rx Tx Rx Tx Rx 45mA 38mA 55mA 40mA 65mA 43mA 75mA 45mA Tx Rx Tx Rx Tx Rx Tx Rx 45mA 45mA 55mA 48mA 65mA 52mA 75mA 55mA Applications Normal J1 Response Time Adjustment (SW1-Rx) One beam broken continued 2 senconds alarm triggered Existed. GND BS-600RC VIN BS-400RC TP2 A Beam Aligned BS-200RC TP1 Conditions 30mm (Height) RX Beams Length (cm) BS-200RC 2 57 BS-400RC 4 105 BS-600RC 6 153 BS-800RC 8 201 Length In-Correct RX TX Terraces (Sliding Door) TX Response Time Slide Switch - SW1 P-073 V7 E JP1 SW1 ON RX SW1 SW1 SW1 ON ON ON ON 1 2 1 2 1 2 1 2 100ms 150ms 200ms TP2 J2 TP1 JP1 pb GND TX 4 VIN RX JP2 J1 (JP2)Jumper When Jumper closed: One beam broken alarm (2 sec.)function existed. When Jumper opened: One beam broken alarm (2 sec.)function removed. (JP1) Jumper When Jumper closed: Buzzer alarm for beam alignment function existed. When Jumper opened: Buzzer alarm for beam alignment function removed. Sunlight Tx External Protections Correct A P-073 V7 C B RX J2 VR1 pb VIN TX GND In-Correct TX RX TP2 Internal Protections JP2 Right side cap Left side cap Correct TP1 3 SW1 50ms 2 NO 1 COM TX Rx D In-Correct RX NC Windows J1 P2 Left side cap Right side cap A: Tamper Switch B: Tamper Switch C: VR1 Potentiometer for Tx power adjustment D: Tamper Switch E: Tamper Switch P3