Manual: Part 2: Adjustment & Operation Standard Signal

   EMBED


Share

Transcript

® ProMinent Operating Instructions DULCOMETER® D1C Part 2: Adjustment and Operation, Measured Variable Standard Signal D1C2-mA-001-GB mA 12.3 % DULCOMETER STOP START mA 12.3 % DULCOMETER STOP START Type D D1C A Type W ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ Please enter the identity code of your device here! Please completely read through operating instructions! · Do not discard! The warranty shall be invalidated by damage caused by operating errors! Part no. 987528 ProMinent Dosiertechnik GmbH · D-69123 Heidelberg · Germany BA_DM_147_04_07_GB.p65 1 BA DM 147 04/07 GB 11.04.2007, 11:02 Uhr 1 D1C A Device Identification / Identity Code DULCOMETER® Controller Series D1C / Version A D W Type of mounting Control panel installation 96 x 96 mm Wall mounting Operating voltage 0 230 V 50/60 Hz 1 115 V 50/60 Hz 2 200 V 50/60 Hz (only with panel installation) 3 100 V 50/60 Hz (only with panel installation) 4 24 V AC/DC Measured variable S Standard signal 0/4-20 mA Connection of measured variable 1 Terminal standard signal 0/4-20 mA Correction variable 0 None Feed forward control 0 None 1 As standard signal 0/4-20 mA 2 As frequency 0-500 Hz 3 As frequency 0-10 Hz Control input 0 None 1 Pause Signal output 0 None 1 Standard signal 0/4-20 mA measured value 2 Standard signal 0/4-20 mA control variable 4 2 standard signal 0/4-20 mA outputs, free programmable Power control G Alarm and 2 limit value/timer relays M Alarm and 2 solenoid valve relays R Alarm relay and servomotor with feedback Pump control 0 None 2 Two pumps Control characteristics 0 None 1 Proportional control 2 PID control Log output 0 None Language D German E English F French I Italian N Dutch S Spanish P Polish A Swedish B Portuguese U Hungarian G Czech D1C A Please enter the identity code of your device here! 2 BA_DM_147_04_07_GB.p65 2 11.04.2007, 11:02 Uhr 2 General User Information Page 1 Device Identification / Identity Code ..................................................................................................... 2 2 General User Information ...................................................................................................................... 3 3 Device Overview / Controls ................................................................................................................... 4 4 Functional Description .......................................................................................................................... 5 5 Display Symbols .................................................................................................................................... 6 6 Operation diagram ................................................................................................................................. 7 7 Restricted Operating Menu ................................................................................................................... 8 Layout .............................................................................................................................................. 8 Description ...................................................................................................................................... 9 8 Complete Operating Menu .................................................................................................................. 12 Overview ........................................................................................................................................ 12 Description .................................................................................................................................... 13 9 Faults/Notes/Troubleshooting ............................................................................................................. 24 General User Information These operating instruction describe the technical data and function of the series DULCOMETER® D1C controller, provide detailed safety information and are divided into clear steps. IMPORTANT • Please observe the parts of these operating instructions applicable to your particular version! This is indicated in the Section “Device Identification / Identity Code”! • Correct measuring and metering is only possible in the case of impeccable operation of the sensor. The sensor has to be calibrated / checked regularly! NOTE A form “Documentation of controller settings type D1C” is available under www.prominent.com/documentation_D1C for the purpose of documenting the controller settings. 3 BA_DM_147_04_07_GB.p65 3 11.04.2007, 11:02 Uhr 3 Device Overview / Controls Display field Measured variable Standard signal (0/4–20 mA) Graphic display ® mA "Start/stop" button "Change" button "Enter" button "Branch back" button DULCOMETER® "Down" button "Up" button STOP START D1C2-mA-002-GB STOP START CHANGE button UP button To change over within a menu level and to change from one variable to another within a menu point. To increase a displayed numerical value and to change variables (flashing display) START/STOP button BRANCH BACK button Start/stop of control and metering function. Back to permanent display or start of relevant setting menu. ENTER button DOWN button To accept, confirm or save a displayed value or status. For alarm acknowledgement. To decrease a displayed numerical value and to change variables (flashing display). 4 BA_DM_147_04_07_GB.p65 4 11.04.2007, 11:02 Uhr 4 Functional Description NOTE Please refer to the description of the complete operating menu in Section 8 for a detailed description of the individual characteristics of the D1C controller! 4.1 Operating Menu The DULCOMETER® D1C controller permits settings to be made in two different menus – a “complete” and a “restricted” menu. All values are preset and can be changed in the complete operating menu. The controller is delivered with a restricted operating menu so that the D1C controller can be used effectively in many applications from the very onset. If adaptations prove to be necessary, all relevant parameters can then be accessed by switching over to the complete operating menu (see “General settings”). 4.2 Access Code Access to the setting menu can be prevented by setting up an access code. The D1C controller is supplied with the access code 5000 which permits free access to the setting menu. The calibration menu remains freely accessible even if access to the setting menu is blocked by the code. 4.3 Control The D1C can operate as a proportional controller or as a PID controller - depending on the device version (see identity code) and the setting. The controlled variable is recalculated once a second. Control procedures which require rapid correction of setpoint deviations (less than approx. 30 seconds) cannot be processed with this controller. The cycle times must be taken into consideration when activating solenoid valves (pulse length) in the same way as their running times when activating servomotors (3-point). Via the control input pause, the control function (selection of controlled variable) can be switched off. The calculation of the controlled variable starts again after cessation of "pause". 4.4 Feed Forward Control The D1C controller can process a signal of a feed forward control. Depending on the device version (see identity code) and the setting, this signal can be obtained in any form of a 0–20 mA or 4–20 mA signal or as a digital contact signal with the maximum frequencies 10 Hz or 500 Hz. This signal can be used, for example, for flow-proportional metering (multiplicative effect) or feedforwarddependent basic load metering (additive effect). The result of control variable calculation from the proportional or PID control is multiplied by or added to the feedforward signal. A multiplicative feedforward variable at the level of the set rated value carries over the calculated control variable unchanged into the controlled variable: Controlled variable = Feedforward variable/rated value x calculated control variable During start-up, the zero point has to be checked. The multiplicative feed forward control is not designed for switching off permanently the actuating variable (signal ≈ 0). An additive feedforward variable at the level of the rated value results in maximum controlled variable: Controlled variable (max. 100 %) = Feedforward variable/rated value x max. controlled variable + calculated control variable 4.5 Error Messages Error messages and information are indicated on the bottom line in the permanent display 1. Errors to be acknowledged (acknowledgement switches off the alarm relay) are indicated by the " ". Errors/notes which still apply after acknowledgement are indicated alternately. Faults which are rectified of their own accord due to changed operating situations are removed from the permanent display without the need for acknowledgement. 5 BA_DM_147_04_07_GB.p65 5 11.04.2007, 11:02 Uhr 5 Display Symbols The display of the DULCOMETER® D1C controller uses the following symbols: Description Comment Limit value transgression Relay 1, upper Symbol Symbol left Symbol Relay 1, lower left Symbol Relay 2, upper right Symbol Relay 2, lower right Metering pump 1 Control off left Symbol Control on left Symbol Metering pump 2 Control off Symbol right Symbol Control on right Solenoid valve 1 Control off Symbol left Control on left Symbol Solenoid valve 2 Control off Symbol right Symbol Control on right Servomotor Control, open relay Control, close relay Without control The bar increases from left to right during opening Position feedback Stop button pressed Manual metering Fault 6 BA_DM_147_04_07_GB.p65 6 11.04.2007, 11:02 Uhr 6 Operation diagram Permanent display 1 The various menus are selected with the CHANGE button The menu is started with the ENTER button Permanent display 2 BRANCH BACK to permanent display or to relevant setting menu Calibration menu Calibration notes Various Access code, correct Setting menus Access code Parameter setting D1C2-mA-007-GB NOTE Access to the setting menus can be barred with the access code! The number and scope of setting menus depends on the device version! If the access code is selected correctly in a setting menu, the following setting menus are also accessible! If within a period of 10 minutes no button is pushed, the unit automatically branches back from the calibrating menu or a setting menu to the permanent display 1. BRANCH BACK without saving setting CHANGE from selection to selection Text 1 Selection 1 Text 2 Selection 2 BRANCH BACK to start of setting Change numbers or settings of selection Variables flash Text 1 Selection 1 Text 2 Selection 2 ENTER and save setting, continue to next menu D1C2-mA-008-GB 7 BA_DM_147_04_07_GB.p65 7 11.04.2007, 11:02 Uhr 7 Restricted Operating Menu / Layout The restricted operating menu permits simple operation of the most important parameters. The following overview shows the settings which can be selected: 12.3 % mea val. fd. fwd.: reg. val.: w: 12.3 % 70 % 59 % 50 % Permanent display 1 Permanent display 2 only with control (w = setpoint) calibration zero-p.: 4.00 mA slope: 100 % calibration meas. value 14.5 % limits setting ? limit 2 30.0 % limit 1 26.0 % Positive values of setting variable: Negative values of setting variable: calibration zero-p.: 4.00 mA slope: 100 % Number and scope of setting menus depends on the device. Access to setting menus con be blocked with access code. upper lower Only with control control regulated value: positive negative control settings ? Proportional control For normal control Setting in complete operating menu control normal current regulat. 30 % value: Control with dead zone or control with dead zone current regulat. value: 30 % or general setting information ctrl. parameter 10 % xp = setpoint 50 % setpoint 2 upper 30 % setpoint 1 lower 28 % PID control ctrl. parameter 10 % xp = 0s Ti = Td = 0s Manual control control manual current regulat. value: 30 % manual dosing 15 % regulated range ident-code: D1CA DxSxxxxxxxxxx software version D1C-B1 FW-5.00 alarm relay active access c.: 5000 operating menu: = english = restricted D1C2-mA-010-GB 8 BA_DM_147_04_07_GB.p65 8 11.04.2007, 11:02 Uhr Restricted Operating Menu / Description Permanent display 1 12.3 % mea val. fd. fwd.: reg. val.: w: 12.3 % 70 % 59 % 50 % Permanent display 2 only with control (w = setpoint) Positive values of setting variable: Negative values of setting variable: D1C2-mA-011-GB Calibration of the standard signal (zero-point calibration) The D1C sets the control output to “0” during the calibration procedure. Exception: When a basic load or a manual control variable is set the corresponding parameter is retained during calibration. The standard signals outputs mA (measured value) are frozen. The measured value frozen at the start of calibration is the proposed value. This value is adjustable (arrow buttons!). Calibration is possible only when the value is ≥2 % of the measuring range. Following successful calibration, all troubleshooting procedures relating to the measured value are restarted. IMPORTANT The measuring range of the sensor must agree with the set measuring range. The unit of measure must be set prior to calibration (see Page 14)! Access to all setting menus can be blocked with an access code ! calibration zero-p.: 4.00 mA slope: 100 % calibration meas. value 14.5 % calibration zero-p.: 4.00 mA slope: 100 % Permanent display 1 D1C2-mA-029-GB Possible values Initial value Increment Lower value Upper value Remarks Measured value 0.1 % 0.01 mA 0.01 m 0.1 % 0.001 bar 0.001 bar 0.01 bar 0.1 bar 0.1 psi 1 psi 0.001 m3/h 0.1 m3/h 1 m3/h 0.1 gal/h 1 gal/h 1 ppm 0.1 %RH 0.01 mA 0.1 % -5 % -1.00 mA 0m 0% 0 bar 0 bar 0 bar 0 bar 0 psi 0 psi 0 m3/h 0 m3/h 0 m3/h 0 gal/h 0 gal/h 0 ppm 0 %RH 0/4 mA 0% 105 % 21.00 mA 31.50 m 105 % 1.050 bar 5.250 bar 10.50 bar 105 bar 105 psi 1050 psi 9.999 m3/h 105 m3/h 1050 m3/h 105 gal/h 1050 gal/h 1050 ppm 105 %RH 21 mA 105 % 30.00 m 100 % 1.000 bar 5.000 bar 10.00 bar 100.0 bar 100 psi 1000 psi 9.999 m3/h 100 m3/h 1000 m3/h 100 gal/h 1000 gal/h 1000 ppm 100 %RH 20 mA 100 % 9 BA_DM_147_04_07_GB.p65 9 11.04.2007, 11:02 Uhr Restricted Operating Menu / Description Limit values Access to all setting menus can be blocked with an access code ! limit 2 30.0 % limit 1 26.0 % limits setting ? upper lower D1C2-mA-014-GB Possible values Initial value Increment Type of limit transgression Limit 1: Limit 2: lower upper upper lower off* Limit value Limit 1: Limit 2: Limit 1: Limit 2: 0% 100 % 0.00 mA 20.00 mA 0.1 % 0.1 % 0.01 mA 0.01 mA Lower value Upper value Remarks Limit transgression when exceeding or dropping below value *only with limit value relay -5 % -5 % -1.00 mA -1.00 mA 105 % 105 % 21 mA 21 mA Measuring unit % Measuring unit mA Control Access to all setting menus can be blocked with an access code ! Note: The controlled variable is recalculated every second. Only suitable for processes with time constants greater than 30 s ! Only with control control regulated value: positive negative control settings ? Setting in complete operating menu control normal current regulat. -30 % value: or Positive values of setting variable: Negative values of setting variable: Proportional control For normal control ctrl. parameter 10 % xp = setpoint 50 % Control with dead zone control with dead zone current regulat. value: -30 % setpoint 2 upper 30 % setpoint 1 lower 28 % or Control manual control manual current regulat. value: -30 % manual dosing 15 % regulated range PID control ctrl. parameter 10 % xp = 0s Ti = Td = 0s D1C2-mA-015-GB 10 BA_DM_147_04_07_GB.p65 10 11.04.2007, 11:02 Uhr Restricted Operating Menu / Description Possible values Initial value Setpoint Control parameter xp Control parameter Ti Control parameter Td Manual metering Increment Lower value Upper value Remarks 50 % 10.00 mA 0.1 % 0.01 mA -5.0 % -1.00 mA 105 % 21 mA Measuring unit: % Measuring unit: mA 2 setpoints necessary for control with dead zone. Setpoint 1 ≤ setpoint 2 10 % off off 0% 1% 1s 1s 1% 1% 1s 1s -100 % 500 % 9999 s 2500 s +100 % xp referred to measuring range Function off = 0 s Function off = 0 s Abbreviation for control variables: xp = 100 %/Kp (inverse proportional coefficient) Ti = I controller integration time [s] Td = D controller differential time [s] General settings Access to all setting menus can be blocked with an access code ! ident-code: D1CA DxSxxxxxxxxxx software version D1C-B1 FW-5.00 general setting information access c.: 5000 operating menu: = english = restricted alarm relay active D1C2-mA-016-GB Possible values Alarm relay Access code Language Operating menu Initial value Increment active active not active 5000 1 as per identity code as per identity code restricted restricted complete Lower value Upper value 1 9999 Remarks Access Code Access to the setting menu can be prevented by setting up an access code. The DULCOMETER® D1C controller is supplied with the access code 5000 which permits free access to the setting menu. The calibration menu remains freely accessible even when access to the setting menu is blocked by the code. 11 BA_DM_147_04_07_GB.p65 11 11.04.2007, 11:02 Uhr 8 Complete Operating Menu / Overview All parameters of the controller can be set in the complete operating menu (access see previous page). The following overview shows the settings which can be selected: 12.3 % mea val. fd. fwd.: reg. val.: w: 12.3 % 70 % 59 % 50 % Permanent display 1 Permanent display 2 only with control (w = setpoint) calibration zero-p.: 4.00 mA slope: 100 % Number and scope of setting menus depends on the device. Access to setting menus can be blocked with access code. measuring unit setting ? measured value setting ? pumps setting ? Only with pumps relays setting ? Only with limit relay, solenoid valve relay or servomotor limits setting ? feed forward ctrl. setting ? Only with feed forward control signal output 1 mA setting ? Only with standard signal output Only with 2 standard signal outputs servomotor setting ? Only with servomotor signal output 2 mA setting ? control setting ? Only with control general setting information D1C2-mA-017-GB 12 BA_DM_147_04_07_GB.p65 12 11.04.2007, 11:02 Uhr Complete Operating Menu / Description Permanent display 1 12.3 % mea val. fd. fwd.: reg. val.: w: Permanent display 2 only with control (w = setpoint) 12.3 % 70 % 59 % 50 % Positive values of setting variable: Negative values of setting variable: D1C2-mA-018-GB Calibration of the standard signal (two-point calibration) The D1C sets the control output to “0” during the calibration procedure. Exception: When a basic load or a manual control variable is set the corresponding parameter is retained during calibration. The standard signals outputs mA (measured value) are frozen. The measured value frozen at the start of calibration is the proposed value. This value is adjustable (arrow buttons!). Calibration is possible only when the value is ≥2 % of the measuring range. Following successful calibration, all troubleshooting procedures relating to the measured value are restarted. IMPORTANT The measuring range of the sensor must agree with the set measuring range. The unit of measure must be set prior to calibration (see Page 14)! calibration zero-pt.: 4.00 mA slope: 100 % calibration meas. value 1 value accept ? 14.5 % calibration value1: 14.5 % value2: calibration meas. value 2 value accept ? 76.6 % calibration value1: 14.5 % value2: 76.6 % calibration zero-pt.: 4.00 mA slope: 100 % Permanent display 1 D1C2-mA-030-GB Possible values Initial value Measured value* Increment Lower value Upper value Remarks 0.1 % 0.01 mA -5 % -1.00 mA 105 % 21.00 mA *for possible measuring values see page 9 Error message Condition Effect Value distance too small ∆ value > 5.0 % ∆ value > 1.00 mA Measured value deleted Repeat calibration of measuring point 13 BA_DM_147_04_07_GB.p65 13 11.04.2007, 11:02 Uhr Complete Operating Menu / Description Measuring variable Access to all setting menus can be blocked with an access code ! measuring unit setting ? measuring value measuring signal measuring unit: 0...100 % Permanent display 1 D1C2-mA-019-GB IMPORTANT The sensor must be recalibrated and the settings in all the menus checked after changing the assigned range! Possible values Initial value Measuring variable Measuring unit Increment Measurement signal Level Pressure Water flow rate Turbidity Humidity Measurement signal 0 - 100 % 0 - 30 m 0 - 100 % 0 - 1.000 bar 0 - 5.000 bar 0 - 10.00 bar 0 - 100.0 bar 0 - 100.0 psi 0 - 1000 psi 0 - 9.999 m3/h 0 - 100.0 m3/h 0 - 1000 m3/h 0 - 100.0 gal/h 0 - 1000 gal/h 0 - 1000 ppm 0 - 100.0 %RH 0/4 - 20 mA 0 - 100 % Lower value Upper value Remarks Level Pressure Water flow rate Turbidity Humidity Measurement signal IMPORTANT The setpoint and limit values are changed over to the corresponding initial values when the measuring range is changed! Check the settings in all menus! 14 BA_DM_147_04_07_GB.p65 14 11.04.2007, 11:02 Uhr Complete Operating Menu / Description Measured value Access to all setting menus can be blocked with an access code ! Standard signal input mA measured value range adjustment 4 mA = 0.0 % measured value setting ? measured value range adjustment 20 mA = 100.0 % measured value checkout time measured value off D1C2-mA-020-GB IMPORTANT When changing the range adjustment, the sensor must be newly calibrated and the adjustments in all menus have to be checked! Possible values Increment Initial value Standard signal input lower signal limit Allocated measuring range* Checkout time Lower value Upper value Remarks 0.1 % 0.01 mA -5 % -1.00 mA 105 % 21.00 mA 1s 1s 9999 s Measurement signal *for other measuring ranges see page 9 Constant measurement signal results in message and alarm. Function off = 0 s 4 mA 0 mA 4 mA 0-100.0 % 0-20.00 mA off Measured value checkout time IMPORTANT This function may not be activated for applications in which it can be assumed that the measured value will not change. This function tests whether the measured value changes from that of the sensor (at the measured value input) within the “Measured value checkout time”. It is assumed that it will do so for an intact sensor. If the measuring value does not change during this checkout time, the DULCOMETER® D1C sets the control variable to “0” and the alarm relay drops out. The LCD display shows e.g. the message “limit 1/2”. Pumps Access to all setting menus can be blocked with an access code ! Only with pumps for control pumps setting ? control dosing pump max. pump1: 180 pump2: 180 pulse/minute pump1 pump2 D1C2-mA-022-GB Possible values Max. stroke/minute of pumps 1 and 2 Initial value Increment Lower value Upper value Remarks 180 1 1 500 off = 0 strokes/min 15 BA_DM_147_04_07_GB.p65 15 11.04.2007, 11:02 Uhr Complete Operating Menu / Description Relay for power control Access to all setting menus can be blocked with an access code ! Only with limit relay, solenoid valve relay or servomotor relay adjustment SV1 relay1: relay2: SV2 relays setting ? solenoid valve 1 solenoid valve 2 10 s period min. time 1 s 10 s period min. time 1 s D1C2-mA-023-GB with timer relay adjustment relay 1: timer relay 2: timer relays setting ? timing 1 relay 1 period t on: timing 2 relay 2 period t on: 1h 1 min 1h 1 min D1C2-mA-033-GB Possible values Initial value Relay adjustment Relay 1 Increment as per identity code Period min. time 10 s 1s Solenoid valve 1 Limit value 1* Actuator 1 Timer 1 Servomotor off Solenoid valve 2 Limit value 2* Actuator 2 Timer 2 off 1s 1s Period t on off 1 min 1h 1 min Relay 2 Lower value Upper value Remarks * At “limit value”, the relays remain active even in the case of fault. Only with servomotor 10 s 1s 9999 s period/2 for solenoid valve for solenoid valve Set here the smallest permitted operating factor of the connected device. 1 h/off 1 min 240 h 60 min for timer for timer NOTE The limit value relay can be defined in such a way as to respond as a control element, i.e. if a limit value relay closes a circuit, it opens when a pause contact is activated and/or for a subsequent delay period td (if td is set to > 0 min in “General settings”). Cycle Timer relay t on on off t 16 BA_DM_147_04_07_GB.p65 16 11.04.2007, 11:02 Uhr Complete Operating Menu / Description IMPORTANT The timer will reset in the event of a power failure. At the end of the (timer) cycle time the DULCOMETER® D1C closes the assigned relay for the duration of “t on” (timer). “Pause” interrupts the timer. When the clock is shown in the LC display the timer can be reset to the start of the cycle at precisely this point using the enter button. The % figure in the LC display indicates the progress of the current cycle. Timer relays may be used, e.g. for shock metering or sensor cleaning. Cycle ton Solenoid valve on min. time t Control variable: 80 % ton = 0.80 Cycle t Control variable: 50 % ton = 0.50 Cycle off Cycle ton on off The switching time of the DULCOMETER® D1C (solenoid valve) depends on the actuating variable and the “min. time” (smallest permitted operating factor of the connected device).The actuating variable determines the ratio ton/cycle and thus the switching times (see fig. above). The “min. time” influences the switching times in two situations: a) theoretical switching time < min. time: Cycle Cycle Cycle min. time on theoretical off Cycle Cycle t Cycle min. time on actual off t ® The DULCOMETER D1C does not switch for a certain number of cycles until the sum of the theoretical switching times exceeds the “min. time”. Then the DULCOMETER® D1C switches for the duration of this total time. b) theoretical switching time > (cycle - min. time) Cycle Cycle and calculated switching time < cycle Cycle min. time on theoretical off Cycle Cycle Cycle t min. time on actual off t The DULCOMETER® D1C does not deactivate for a certain number of cycles until the differences between cycle and theoretical switching time exceed the “min. time”. 17 BA_DM_147_04_07_GB.p65 17 11.04.2007, 11:02 Uhr Complete Operating Menu / Description Limit values Access to all setting menus can be blocked with an access code ! limit 2 30 % limit 1 28 % limits setting? upper lower relay 1: LV1 - active closed ∆t on: 0s ∆t off: 0s limits fault hyst.: 0.2 % ∆t on: off control: on relay 2: LV2 - active closed ∆t on: 0s ∆t off: 0s D1C2-mA-034-GB Possible values Initial value Increment lower upper upper lower off* Limit 1: Limit 2: 0% 100 % 0.1 % 0.1 % -5 % -5 % 105 % 105 % Measuring unit percent Limit 1: Limit 2: 0 mA 20 mA 0.01 mA 0.01 mA -1.00 mA -1.00 mA 21 mA 21 mA Measuring unit milliampere 0.2 % 0.04 mA 0.1 % 0.01 mA 0.1 % 0.02 mA 105 % 21.00 mA Active in “cancellation of limit transgression” direction Checkout time limits off 1s 1s 9999 s Results in message and alarm. Off = 0 s: Function switched off, no message, no alarm Control on on off active closed active closed active open Type of limit transgression Limit 1: Limit 2: Limit value Hysteresis limits Switching direction Limit value 1 Limit value 2 Lower value Upper value Remarks Limit transgression when exceeding or dropping below value *only with limit value relay Acts as N/O Acts as N/C Switch-on delay ∆t on 0s 1s 0s 9999 s Switch-off delay ∆t off 0s 1s 0s 9999 s If the limit transgression is applied longer than the “delay time limit values”, an error message is triggered and the alarm relay drops out; the control procedure stops if “control” is additionally set to “off”. 18 BA_DM_147_04_07_GB.p65 18 11.04.2007, 11:02 Uhr Complete Operating Menu / Description Servomotor The operating range is defined by the total resistance range of the feedback potentiometer. The maximum limit of the range actually used is set by defining the control range. IMPORTANT • Activation of the servomotor must be carried out with the same meticulous care as taken when calibrating a measuring sensor. • To ensure correct operation, the activation time of the actuator used should not be less than 25 seconds for the control range from 0…100 %! Access to all setting menus can be blocked with an access code ! Only with servomotor servomotor setting current position: servomotor setting ? servomotor open ? servomotor open please wait ! servomotor opened ! value take over ? servomotor close ? servomotor close please wait ! servomotor closed ! value take over ? servomotor OK current position: dosing: control range: 100 % 0 % to operating range = automatic timing D1C2-mA-025-GB Possible values Servomotor Initial value Increment Setting Setting ok off 100 % 1% Lower value Upper value Remarks 10 % 100 % in % of operating range Control direction Control range NOTE • When the wide bar is as right as it will go, the stroke adjustment motor is fully open. • The permanent display shows to what degree the motor has opened in % (the greater the percentage, the more open the servomotor.) 19 BA_DM_147_04_07_GB.p65 19 11.04.2007, 11:02 Uhr Complete Operating Menu / Description Control Access to all setting menus can be blocked with an access code ! Note: The controlled variable is recalculated every second. Only suitable for processes with time constants greater than 30 s ! Only with control control regulated value: positive negative control settings ? control normal current regulat. value: 30 % Positive values of setting variable: Negative values of setting variable: Proportional control For normal control ctrl. parameter 10 % xp = setpoint 50 % Control with dead zone PID control setpoint 2 upper 30 % Setpoint 1 lower 28 % ctrl. parameter 10 % xp = 0s Ti = Td = 0s Control manual add. basic load 10 % regulated range manual dosing 15 % regulated range D1C2-mA-026-GB Possible values Initial value Increment Control normal normal with dead zone manual Setpoint 50 % 10.00 mA 0.1 % 0.01 mA -5.0 % -1.00 mA 105 % 21 mA 10 % off off 0% 0% 1% 1s 1s 1% 1% 1% 1s 1s -100 % -100 % 500 % 9999 s 2500 s +100 % +100 % Control parameter xp Control parameter Ti Control parameter Td Additional load Manual metering Lower value Upper value Remarks When controlling with dead zone, the feed forward control is not used for measured values within the dead zone. Measuring unit: % Measuring unit: mA 2 setpoints necessary for control with dead zone. Setpoint 1 ≤ setpoint 2 xp referred to measuring range Function off = 0 s Function off = 0 s Abbreviation for control variables: xp = 100 %/Kp (inverse proportional coefficient) Ti = I controller integration time [s] Td = D controller differential time [s] 20 BA_DM_147_04_07_GB.p65 20 11.04.2007, 11:02 Uhr Complete Operating Menu / Description Feed forward control feed forward ctrl. feed forward ctrl. setting ? Hz/mA 10 Hz feed forward ctrl. disturb. variable additive feed forward ctrl. rated value 10.00 Hz feed forward ctrl. max. additive regulated value 100 % D1C2-mA-031-GB Possible values Feed forward control (Flow) Initial value Increment as per identity code Standard signal 4–20 mA None 10 Hz 500 Hz 0…20 mA 4…20 mA 10 Hz 500 Hz 20 mA 0.01 Hz 1 Hz 0.1 mA multiplicative multiplicative additive 100 % 1% Feed forward control rated value Feed forward control feed forward control effect Feed forward control additive regulated value Lower value Upper value Remarks Signal processing: Signal <0.02 Hz = No flow Signal <0.2 Hz = No flow Signal <0.2 mA = No flow Signal <4.2 mA = No flow 0.1 Hz 5 Hz 0.4 mA 10 Hz 500 Hz 20 mA Depended on signal type. Maximum limitation of range used. -500% +500% only with additive feed forward control Standard signal output 1 Access to all setting menus can be blocked with an access code ! Control with standard signal Only with standard signal output signal output 1 mA setting ? signal output 1 mA measured value 0…20 mA control regulated value: positive negative signal output 1 regulated value 0% 0 mA = 20 mA = 100% signal output 1 measured value 0% 0 mA = 20 mA = 100 % D1C2-mA-027-GB 21 BA_DM_147_04_07_GB.p65 21 11.04.2007, 11:02 Uhr Complete Operating Menu / Description Standard signal output 2 Access to all setting menus can be blocked with an access code ! Control with standard signal Only with 2 standard signal outputs signal output 2 mA setting ? signal output 2 mA measured value 0…20 mA signal output 2 regulated value 0% 0 mA = 20 mA = 100% control regulated value: positive negative signal output 2 measured value 0% 0 mA = 20 mA = 100 % D1C2-mA-032-GB Possible values Variable allocation Output range Initial value Increment as per identity code Measured value Controlled variable 0…20 mA 0…20 mA 4…20 mA 3.6/4-20 mA Lower value Upper value Remarks If control applicable Reduction to 3.6 mA when alarm relay switches (not limit value violation) Range measured value 0-100 % 0-20.00 mA 0,1 % 0,01 mA -5 % -1,00 mA 105 % 21,00 mA Minimum range 1 % of measured value Range controlled variable 0 %…+100 % 1% -100 % +100 % Minimum range 1 % General setting Access to all setting menus can be blocked with an access code ! general setting information ident-code: D1CA DxSxxxxxxxxxx software version D1C-B1 FW-5.00 alarm relay active pause normal - active closed - alarm off - td: 0 min access c.: 5000 operating menu: - english - complete D1C2-mA-028-GB 22 BA_DM_147_04_07_GB.p65 22 11.04.2007, 11:02 Uhr Complete Operating Menu / Description Possible values Initial value Increment Alarm relay active active not active Pause normal normal hold active closed active closed active open Reacts as a make contact Reacts as a break contact off off on Alarm relay can be triggered by pause contact td 0 min 1 min 0 min 60 min Access code 5000 1 1 9999 as per identity code as per identity code complete restricted complete Control input pause Alarm pause Language Operating menu Lower value Upper value Remarks Normal pause If the pause switch is off, the DULCOMETER® D1C sets the operating outputs to “0” for as long as the pause switch is off or for a set time delay td (if td is set to > 0 min). While the pause switch is off, the D1C establishes the P-proportion in the background. With PID-control (identity code characteristics “control characteristic” = 2): the I-proportion is stored when the pause is switched off (I-proportion then usually only present if Ti > 0 has been selected in the “Control setting?” setting menu). Exception: the standard signal outputs mA for the measured value or correction value are not affected by the pause. After pause is activated, the operating outputs remain at “0” for the length of the time delay td. The time delay td must be set up in such a way that in this time e.g. sample water (process-specific current concentration) flows to the sensor. With PID-control (identity code characteristics “control characteristic” = 2): The control variable output resulting from the pause and the expiry of the time delay td is reconciled jointly with the current P-component and (if Ti is set > 0) with the stored I-component. Pause hold If the pause switch is off, the DULCOMETER® D1C freezes the operating output at the most recent value for as long as the pause switch is off or for a set time delay td (if td is set to > 0 min). Whilst the pause switch is off, the D1C establishes the P-proportion in the background. With PID-control (identity code characteristics “control characteristic” = 2): Even the mA standard signal outputs for measured value or correction value are frozen. After pause is activated, the operating outputs remain frozen for the length of the time delay td. The time delay td must be set up in such a way that in this time e.g. sample water (process-specific current concentration) flows to the sensor. With PID-control (identity code characteristics “control characteristic” = 2): The control variable output resulting from the pause and the expiry of the time delay td is reconciled jointly with the current P-proportion and (if Ti is set > 0) with the newly established I-proportion. Access Code Access to the setting menu can be prevented by setting up an access code. The DULCOMETER® D1C controller is supplied with the access code 5000 which permits free access to the setting menu. The calibration menu remains freely accessible even when access to the setting menu is blocked by the code. 23 BA_DM_147_04_07_GB.p65 23 11.04.2007, 11:02 Uhr Faults / Notes / Troubleshooting 9 Stop Yes Alarm with acknowledgement Function detachable Remarks Check function of sensor, exceed checkout time Remedy Yes Yes – 24 Effect on metering on control Fault text Basic load Symbol Fault Check probe Check sensor, transducer and cable connection Measured value Checkout time measured value exceeded Signal < 3.8 ±0.2 mA or >23 ±0.2 mA Value last valid is used Define cause, reset values if necessary Check sensor, transducer and cable connection Function detachable Call in service Check servomotor Signal <3.0 ±0.2 mA or >23 ±0.2 mA Servomotor closes Yes Yes Electronic data defective Yes Yes Stop continue continue continue Stop Stop Relay drops out – Remedy Yes Basic load stops continue continue Stop or Basic load Stop No/Yes* No Check connection of relay, potentiometer Adjust the operation region of the servomotor correctly No further fault check Remarks input 3 mA input > 23 mA Symbol Stop PI-part frozen Stop Effect on metering on control Stop Stop Alarm with acknowledgement Signal exceeded/drops below value System defect. Servomot. defect. Feed forward control feedfwd input <4 mA Signal drops below value multiplicative additive feedfwd input >23 mA Signal exceeded Limit 1 Limit transgression Limit 2 after checkout time limits Control “on” Control “off” Servomotor Position not reached Stop Pause Pause/Hold Note text Electronics error Operation Pause contact Stop button Without correct adjustment the last valid values are still used 11.04.2007, 11:02 Uhr 24 BA_DM_147_04_07_GB.p65 During servomotor setting Direction check Position feed back wrong Upper position <40 % max. value Final value too small Final value too big Lower position >30 % range *depending on whether "Alarm on" or "Alarm off" set in "General settings" ©1996 ProMinent Dosiertechnik GmbH · D-69123 Heidelberg Operating Instructions DULCOMETER® D1C, Part 2/Standard Signal Subject to modifications · Printed in the F.R.Germany ProMinent Dosiertechnik GmbH · Im Schuhmachergewann 5-11 · D-69123 Heidelberg Phone +49 6221 842-0 · Fax +49 6221 842-419 [email protected] · www.prominent.com