1
5 Jumper inserted at factory
6
7
2
Caution: Equipment Damage When disposing, keep this product separate from household waste; recycle this product
Caution: Risk of Electric Shock
Double or Reinforced Insulation; Grounding is unnecessary
Caution: Hot Surface
Refer to Operating Instructions
LED Indicators Compartment Cover Screw PV Input
Battery Input Load Output
Thermistor (Battery Temperature) Battery Voltage Sensing
Data Communications
CAUTION: Hazard to Equipment Proprietary adapter is required. Do not connect directly to computer or Ethernet.
, , and : Use flat screwdriver with tip width <6 mm and blade length >50 mm and : Use flat screwdriver with tip width <3 mm and blade length >50 mm
3
Specifications Section
Name
12 Vdc
24 Vdc
Controller Type Wattage (maximum)
PV
150 W 25 to 100 Vdc
40 to 100 Vdc
Vmp (range)
15 to 70 Vdc
27 to 70 Vdc
Name
12 Vdc 0.25 Adc
Maximum Output Current
10 Adc
Internal Protection
Internal Protections
Battery Reversal, PV Reversal
Load Disconnect (Automatic Reset)
Low Battery, High Battery, Overload
Load Disconnect (Manual Reset)
Overload (after 3 automatic resets) 11.4 Vdc*
22.8 Vdc*
10 Adc
Low Battery Load Reconnect
12.4 Vdc*
24.8 Vdc*
Battery Type ( jumper-selectable)
Flooded or VRLA
High Battery Load Disconnect
15.0 Vdc
Low Battery Load Disconnect
30.0 Vdc
12 or 24 Vdc; automatically detected
Battery Input (range)
9 to 16 Vdc
18 to 32 Vdc
Dimensions
3 mAdc to 14 mAdc (sleep) and 80 mAdc (awake)
Efficiency (maximum) Flooded
VRLA
Flooded
VRLA
Bulk
14.8 Vdc*
14.6 Vdc*
29.6 Vdc*
29.2 Vdc*
Absorb
14.8 Vdc*
14.4 Vdc*
29.6 Vdc*
28.8 Vdc*
Absorb Time Float Voltage Charging Current (maximum)
13.5 Vdc*
26.4 Vdc*
Cabling
27.0 Vdc*
10K NTC
Environment
Equalize Equalization Time
15.5 Vdc*
--
Battery
10 mm2 (#7 AWG)
PV
6 mm2 (#9 AWG)
Battery Sense Required Size
0.33 to 0.08 mm2 (#22 to 28 AWG)
Terminal Torque Value
5.0 Nm (50 in-lb)
31.0 Vdc*
Not required Battery
≤ 20 Adc, ≥ 100 Vdc
PV
≤ 10 Adc, ≥ 100 Vdc
Operating Temperature
NOTE: Enabled by removing battery jumper; loads turned off while equalizing NOTE*: Occurs every 60 days, or following a low battery load disconnect Equalization Voltage (maximum)
≤32 mm2(#4 AWG)
NOTE: Larger cables must be used if battery cables exceed 3 m length NOTE: Battery cables must be twisted together during installation
External Protection (recommended) Follow all local codes to select overcurrent protection.
-5 mV / °C / battery cell*
Thermistor
~ 0.5 kg
Grounding
10 Adc*
Temperature Compensation (range)
Weight
Cable Size (minimum)
2 hours* 13.2 Vdc*
197 mm (7.8”) X 110 mm (4.3”) X 45 mm (1.8”)
Size
Terminal Size(PV and battery)
97%
Bulk and Absorption Voltages (maximum) for Battery Types
1 hour*
Humidity
-40 °C to 60 °C 0 to 95% RH non-condensing
Ingress Protection
--
*Number shown is factory default setting. Consult the battery manufacturer for specific charger settings. Item is settable with communications interface.
Battery Bank Certifications
IP20 Minimum 50Ah at C/5 discharge rate CE,EN 61000-6-1,EN 61000-6-3, IEC/EN 62109-1
Warranty
Troubleshooting Problem
Possible Remedies (perform in order shown)
Battery not charging No LED indicators with PV power available Red LED on
1) Check battery connections 2) Check PV voltage and connections 3) Allow charger to cool 1) Check battery voltage at controller terminals 2) Check panel voltage at controller terminals 1) Disconnect PV 2) Disconnect battery 3) Disconnect load 4) Reconnect battery 5) Reconnect PV 6) Reconnect load 1) Disconnect loads 2) Charge battery Charge battery 1) Check position of battery selection jumper 2) Check installation of thermistor
Red LED flashing Yellow LED not on Charging to wrong voltage
4
24 Vdc
Minimum Load Size
Short Circuit Current (maximum)
Self-consumption
Charger
Loads
300 W
Voc (range) NOTE: Will not operate above 85 Vdc
Nominal Voltage
Battery
Section
MPPT
2 years