GB PRE-INSTALLATION CARD ART. 258R (mm 1250 x 1250) 0 105 125 0 115 0 110 2235 80 350 650 1950 0 520 960 Measurements in mm. N.B. Installation must take place once floors and walls are completed. The room in wich the sauna is to be installed should be at least 240 cm high for service and maintenance purposes. Siphon 97 - Hot water connection for 1/2" tap fittings - Cold water connection for tap fittings and sauna 1/2" O - Connection for drainage pipe recessed in floor Ø40mm CA - Electrical connection for whirlpool IPX5 (box with cable press PG 13,5) CA1 - Electrical connection for sauna IPX5 (box with cable press PG 13,5) Ø 40 C F 160 Electric connections must be effected in accordance with safety regulations for bathroom installation as described in the enclosed instruction booklet. ART. 258R ELECTRICAL CHARACTERISTICS HYDRAULIC CHARACTERISTICS Whirlpool Multifunctions Sauna Net Water Floor Delivery Delivery Drain Weight Content(1) Load Weight Volume Vers. Vert. Back Foot Cent. Capacity Min.Max. Min.Max. Supply Conn. Water Air Kg. Kg. Kg/m2 Kg. m3 No. Jets Capacity Capacity Jets Jets Jets Sh.He. l/min Pressure Pressure Easy 6 165 170 310 264 3,3 Top 6 300 210 l/min. l/min. 6 3 2 1 9 ÷16 2 ÷ 5 bar 1÷ 5 bar 1/2" Whirlpool Art. Ø40 1WEX38 mm 1WTX28 (2) Sauna Kw Art. Kw 1 3MEX18 2,9 (1) - Overflow level. (2) - Before connecting the appliance, make sure that the voltage indicated on the rating plate is the same as that of the electric mains. The information and characteristics shown do not bind Teuco Guzzini srl who reserves the right to make any modifications it retains necessary without any prior warning or notice of replacement. 14 ASSEMBLING THE CABINET GB 1 All screws and accessories which are necessary for installation are in the appropriate box 5 8 11 Bag (A) with scres for steps 1 - 3 3a - 3b - 3c 11 10 PREPARING FOR FIXTURE TO THE WALL 1975 2030 P Make the holes for fixing the hydroshower to the wall by following the measurements indicated in the diagram. Fix clamp (P) to the wall with a stop-screw. POSITIONING THE BATHTUB 2 F C X Prepare the holes for the wall taps with filter for connection of the hot (C) and cold (F) water with “T” coupling. Remove the screws indicated by the arrow in order to remove the front panel. Pull the bottom part of the panel towards you so that the (Y) clips come out of their respective housings. Place the bathtub in the corner of the bathroom and make sure it is on a level by using the appropriate adjustable feet. Prepare the drain connection by using the supplied syphon. Y 15 GB ASSEMBLING THE CABINET 3 FITTING THE BACK PANELS A C1 C1 M5X25 Ø5 M5X25 Ø5 C Move the bathtub away from the corner so as to proceed with subsequent assembly steps. Remove the screw from the end of the lower track. Apply silicone to the track end as shown in the diagram. Place back panel (A) onto the bathtub by inserting the upright onto the end of the lower track. Fix the panel with the previouslyremoved screw and washer (C). Insert the screws and washers (C1) for fixture to the bathtub. Make sure to insert the screw marked (!) into the indicated hole. 4,2x60 Ø5 3a Place back panel (B) onto the bathtub and fix to panel (A) by using the screws with washers and nuts (C2). M5X25 Ø5-M5 C2 B A 16 ASSEMBLING THE CABINET GB 3b Bag (D) plastic accessories M3x8 Ø4 C2 M B D C1 M5x25 Ø5 4,2X45 Ø5 C 3c Remove the screw from the end of the lower track. Apply silicone as indicated and in the part of the track groove that matches the side panel. Place back panel (D) onto the bathtub. Fix the panel to the track with the previously-removed screw and washer (C). Insert the screws with washers (C1) for fixture to the bathtub. Fit the rubber doorstop onto panel (D) with the screw and washer (C2). Join panel (D) and (B) with the screws, washers and nuts (C2). Tighten screws (C1) on the bathtub. M5x25 Ø6-M5 D A C2 B M5x25 Ø5 C1 C1 C1 C1 17 GB ASSEMBLING THE CABINET 4 Bag (B) with screws for steps 4 - 5 - 8 - 9 FITTING THE SIDE PANEL C D Ø5-M5 C E FITTING THE UPPER TRACK 5 Remove the screws from the ends of the upper track. Insert the track onto the end of the uprights. Fix the upper track to the back panel using the previously-removed screws and washers (C1). Tighten the screws on the ends of the side panel upright (E). C1 4,2x60 Ø5 4,2x45 Ø5 C1 E E 18 Move panel (E) carefully and insert it onto the bathtub track, leaving a space of a few centimetres from the back panel. Place the threaded dowels onto the upright of side panel (E) so that they match up with the holes on back panel (D); if necessary, use a 2.5 Allen key. Check that gasket (!) fits properly along the entire length of the side panel upright. Slide side panel (E) so that it meets with back panel (D) and tighten with the screws with nuts and washers (C). ASSEMBLING THE CABINET GB 6 APPLYING SILICONE 7 FITTING THE DOOR Apply a NEUTRAL (NON ACETIC) silicone so as to prevent water leaks between the back panels and the bathtub. C D N Insert the track covers (V) and the end-trim (Y) into the top and bottom tracks. Turn the nut (D) until it is flush with the top of the “C” screw. Mount the door, hooking the wheels (P) with the spring support onto the lower track Lift the door up so that the top wheels (N) slide into the track. V Y ONLY FOR ART.258R WITH EASY WHIRPOOL V P Y Fit the door by inserting it between the EASY control panel and the lower track; then insert upper bearings (P) into the upper track. Y ! V 19 GB ASSEMBLING THE CABINET CENTRING THE DOOR 8 Fit the handle onto the door support and tighten the screws (C). Then insert the piece of trim. K D Close the door and make sure that the magnetic seals are aligned along the entire length of the door. In the event that the seals do not come together - as in case (A) or case (B) - adjust the top slide assembly indicated by the arrow. - Lift the door, grasping it by the supports. - Tighten the screw (D) until the magnetic seals are aligned. N.B. After adjusting the slide assembly, lock the nuts (D) in place, inserting the covers (K) with the inner wings facing outwards. M4x30 C A 9 B FITTING THE DOME C3 Apply the steam-tight adhesive gasket to the top of the back panels, making it pass behind the holes for the fixture of the dome. Position the dome by inserting its edge into the cabinet track, making sure that gasket (G) faces the inside of the cabinet. Fix the dome with screws (C3). M5x25 Ø5 G G 20 CONNECTIONS FOR VARIOUS MODELS GB 258 R - Multifunction Hydrosteam WATER CONNECTIONS A1 D 1 2 5 A2 F C A3 A4 3 10 A5 Once caps (D) have been removed, they are not re-usable. C - Hot water connection. Use a 60 cm flexible stainless steel tube and connect to the tap with filter. F - Cold water connection. Use a 60 cm flexible stainless tube and a “T” coupling for connection to the tap with filter. A1 - Connection of tube 1 and 2 for the sauna and tube 5 for the shower outlet with vaporizer. A2 - Cleaning the taps with filter. A3 - Connection of tube 3 (draining). A4 - Connection of tube 10 for the back massage. A5 - Water connection diagram for the model with thermostatic mixer. When installing the stopcock, make sure to follow the direction shown by the arrow. F C 21 GB CONNECTIONS FOR VARIOUS MODELS 258 R - Multifunction Hydrosteam ELECTRICAL CONNECTIONS A1 CA1 N Blue Yellow Green P Brown A2 Blue N Yellow Green Brown P CA Electrical connections must be made in compliance with safety standards relative to bathroom installations as described in the enclosed manual for use. CA - Electrical connection for whirlpool IPX5 (box with cablepress PG 13.5) CA1 - Electrical connection for sauna IPX5 (box with cable-press PG 13.5). A1 - Connection of dome cable to power unit cable. A2 - Connection of whirlpool power unit cable to control panel. 22 CONNECTIONS FOR VARIOUS MODELS GB 11 EQUIPOTENTIAL CONNECTION 1 2 3 4 Use the yellow-green wire to connect the metal parts of the appliance as shown in the diagram. Connect the other yellow-green wire which is under the bathtub edge as shown. A clamp for equipotential connection to other earth wires in the bathroom is available at point (1). N.B.: Should your model not have one of the components shown in the diagram, isolate the relative “fast-on”. 5 9 7 8 10 1 PANEL FRAME WITH TAP FITTINGS 2 EMERGENCY TAP 3 SHOWER SUPPORT POLE 4 STOPCOCK FOR THERMOSTATIC MIX 5 MIX OR THERMOSTATIC MIX 6 FAST-ON TO BE ISOLATED 7 WATER OUTLET 8 PANEL FRAME WITH MIRROR 9 10 PANEL FRAME WITH TAP FITTINGS PUMP SUPPORT 23 GB ASSEMBLING THE CABINET 12 USING THE SYSTEM FOR THE FIRST TIME Once all the connections have been made and before definitively fixing the cabinet to the wall, remove all stickers. Carry out a regeneration cycle and a sauna cycle by following the instructions in the enclosed manual for use. Check that there are no water leaks from the connections and that everything is operating normally. Should the sauna system not work after connection to the electric mains has been made, press the red button (1) on the power unit box. Should the control panel signal a fault (with the flashing of all leds) when the sauna is used for the first time, press the thermostat reset button (2) which is on the boiler cover so that it clicks. 2 1 13 HYDRAULIC CHARACTERISTICS Diagram of mixed water capacity diagram for the various functions. l/min 15 10 5 0 24 1 2 3 4 5 Bar Vertical massage Foot massage Massaging shower Back massage Overhead fixed shower with nebulizer Spout ASSEMBLING THE CABINET GB 14 M5x25 Ø5 C1 C T T1 M5x16 Ø5-M5 C2 4,2x38 Ø5 Y T2 X M4x20 Bag (C) screws for step 14 FIXTURE TO WALL Move the hydrosauna towards the corner of the bathroom. Fix plate (T1) with the stop-screw, screw, nut and washer (C1). Fix the cabinet with plate (T) and screw with washer (C). Fix the bathtub to the floor with plates (T2) and stop-screws. Fit the side door by sliding it down from the top so as to hook it onto the support bracket on the frame. Fix the side door by tightening the towel-rail knob with the screw and washer (C2); insert the trim. Re-fit the bathtub panel by inserting the top edge underneath the bathtub and pressing clips (Y) so that they go back into their respective housings; fix the panel with the previously-removed screw. 25