Preview only show first 10 pages with watermark. For full document please download

Maple Systems, Inc.

   EMBED


Share

Transcript

CONTROLLER INFORMATION SHEET Maple Model(s) Graphic HMIs cMT Series PLC or Controller NMEA 0183 Interface Standard P/N: 1036-0249 Rev. 00 Date: 04/25/2017 Summary Maple Systems HMIs communicate with devices using the NMEA 0183 (National Marine Electronics Association) interface standard. Communications Cable The HMI should be connected to the device’s serial port. A list of cables offered by Maple Systems as well as cable assembly instructions to assist you in assembling your own communications cable is available on our website. WARNING If your communications cable is not wired exactly as shown in our cable assembly instructions, damage to the HMI or loss of communications can result. Controller Settings: The device’s communication parameters must be the same as that specified in EZware’s “COM Port Settings.” . 1036-0249 Maple Systems Inc., 808 134th Street SW, Suite 120, Everett, WA 98204-7333 Page 1 of 4 Rev. 00, 04/25/2017 NMEA Sentences: The following table lists the NMEA sentences that are supported in EZwarePlus. Sentence AAM ACK ADS AKD ALA ALM ALR APB BEC BOD BWC BWR BWW COP CUR DBT DCR DDC DOR DPT DSC DTM ETL EVE FIR FSI GBS GGA GLC GLL GMP GNS GRS GSA GST GSV HDG HMR HMS HSC HSS HTC HTD . 1036-0249 Description Waypoint Arrival Alarm Alarm Acknowledge Automatic Device Status Acknowledge Detail Alarm Condition Set Detail Alarm Condition GPS Almanac Data Set Alarm State Heading/Track Controller (Autopilot) Sentence “B” Bearing and Distance to Waypoint – Dead Reckoning Bearing – Waypoint to Waypoint (Origin to Destination) Bearing and Distance to Waypoint – Great Circle route Bearing and Distance to Waypoint – Rhumb Line Bearing – Waypoint to Waypoint Configure the Operational Period Water Current Layer Depth Below Transducer Device Capability Report Display Dimming Control Door Status Detection Depth of Water Digital Selective Calling Information Datum Reference Engine Telegraph Operation Status General Event Message Fire Detection Frequency Set Information GPS Satellite Fault Detection GPS Fix Data Geographic Position, Loran-C Geographic Position, Latitude/Longitude GPS Map Projection Fix Data GPS Fix Data GPS Range Residuals GPS DOP and Active Satellites GPS Pseudorange Noise Statistics GPS Satellites in View Heading – Deviation and Variation Heading – Monitor Receive Heading – Monitor Set Heading – Steering Command Heading/Track Control Command Heading/Track Control Data Maple Systems Inc., 808 134th Street SW, Suite 120, Everett, WA 98204-7333 Page 2 of 4 Rev. 00, 04/25/2017 LCD MLA MSK MSS MTW MWD MWV NAK NRM OSD PRC RMA RMB RMC ROR ROT RPM RSA RSD RST SFI SID STN THS TLL TRD TTM TUT TXT UID VBW VDR VER VHW VLW VPW VTG WAT WCV WNC WPL XTE XTR ZDA ZDL ZFO ZTG . 1036-0249 Loran-C Signal Data GLONASS Almanac Data Control for a Beacon Receiver (MSK Receiver Interface) Beacon Receiver Signal Status information (MSK Receiver Signal) Mean Temperature of Water Wind Direction and Speed Wind Speed and Angle Own Ship Data Recommended Minimum Navigation information A (Loran-C Data) Recommended Minimum Navigation information B Recommended Minimum Navigation information C (Specific GNSS Data) Rate of Turn Revolutions Per Minute Rudder Sensor Angle RADAR System Data Scanning Frequency Information Multiple Data ID Target Latitude and Longitude Tracked Target Message Transmission of Multi-language Test Text Transmission Dual Ground / Water Speed Set and Drift Water Speed and Heading Distance Traveled through Water Speed – Measured Parallel to Wind Track Made Good and Ground Speed Waypoint Closure Velocity Distance – Waypoint to Waypoint Waypoint Location information Cross Track Error – Measured Cross Track Error – Dead Reckoning Date and Time Time and Distance to Variable Point UTC and Time from Origin Waypoint UTC and Time to Destination Waypoint Maple Systems Inc., 808 134th Street SW, Suite 120, Everett, WA 98204-7333 Page 3 of 4 Rev. 00, 04/25/2017 EZware Settings The following table lists the communications settings that must be configured in EZware. These settings can be found in the Edit-System Parameters menu under the PLC Settings > Device Properties. Please note:   The Recommended Settings column provides the recommended setting based upon default settings most commonly used in Devices which use the NMEA 0183 interface standard. The Options column lists EZware’s options; your controller may not support every option Name Recommended Settings Name: NMEA 0183 HMI or PLC PLC Options Description label Local; Remote Location Local PLC type: NMEA 0183 PLC I/F: RS-232 RS-232, RS-485 2W, RS485 4W Settings: COM: COM 1 COM 1 – COM 3 Settings: Baud rate: 4800 4800, 9600, 19200, 38400, 57600, 115200 Settings: Data bits: 8 7 or 8 Settings: Stop bits: 1 1 or 2 Settings: Parity None Even, Odd, None Settings: Timeout 1.0 0.1 to 25.5 Settings: Turn around delay 0 0 to 1000 . 1036-0249 Important Notes Select Local if PLC directly connected to HMI; Remote if PLC connected thru another HMI. Serial port of HMI connected to PLC. Must match the PLC’s port setting. Must match the PLC’s port setting. Must match the PLC’s port setting. Must match the PLC’s port setting. Adjust if longer timeout is required. Timeout period between HMI polls. Maple Systems Inc., 808 134th Street SW, Suite 120, Everett, WA 98204-7333 Page 4 of 4 Rev. 00, 04/25/2017