Preview only show first 10 pages with watermark. For full document please download

Maxilux

   EMBED


Share

Transcript

Maxilux Good light is an essential prerequisite for good performance. That applies especially to large sports facilities and multifunctional arenas: In many large-scale projects, the TRILUX Maxilux compact floodlights have proven themselves and their capabilities. And even wherever sports are not top priority, just a lot of light, e.g. at large-scale building sites and in high halls, the Maxilux floodlights are impressive as industrial lighting solutions. Easy re-lamping The cover mounted on the back and with integrated socket carrier can be opened for maintenance purposes. Thus, the lamp housing is easily accessible and the re-lamping especially uncomplicated. Hot re-ignition Maxilux versions with instantaneous hot re-ignition (WZ) have a fully electronic ignition management system. State-of-the-art microprocessor technology allows for flicker-free and lamp-preserving rapid lamp start of even hot lamps. Automatic safety cut-off and end-of-life detection prevent abnormal lamp operation and protect the components of the luminaire. TRILUX Spotlights and Floodlights Four optical systems offer maximum planning scope Reflector T narrow-angle light distribution. Reflector TB narrow/wide-angle light distribution. C0 C0 C90 C90 C270 C270 C180 C180 Reflector B wide-angle light distribution. Reflector SB extremely wide-angle light distribution. C0 C0 C90 C90 C270 C270 C180 C180 Maxilux Compact Floodlight 6 5 a IP65 7-420··· Compact floodlight with pseudo rotationally symmetrical light distribution. Floodlight housing made of an anodised aluminium reflector and an anthracite base made of die-cast aluminium, additionally anodised. With flange-mounted, thermally decoupled ignitor tray and pressure equalisation vent. Cover made of 5 mm thick, thermally toughened safety glass, equipped with a silicon seal and held secure to the reflector part using non-rusting clips, a mesh cover is not necessary. Fixing bracket made of galvanised steel, continuously adjustable, suited for upright and suspended mounting of floodlight. Optical systems The aluminium reflector forms the rotationally symmetrical reflector, which has a highly-specular or semi-specular anodised inner surface. With internal highly-specular shield. Pseudo rotationally symmetrical light distribution. T narrow-angle, reflector highly-specular. TB narrow/wide-angle, reflector highlyspecular. B wide-angle, reflector semi-specular. SB extremely wide-angle, reflector semispecular. Re-lamping is simple after loosening four captive stainless steel screws and opening the back cover with mounted fixture and reflector components. Electrical connection using enclosed, lockable connector with cable gland Pg13.5, with 4-pole terminal for wires up to 2.5 mm². When opening the housing to change the lamp, the connector must be unplugged and the floodlight must be disconnected from power supply. Versions with ignitor, optionally for instantaneous hot re-ignition (WZ). Others components required for operating the floodlight must be ordered separately and mounted, see Accessories. WZ versions with attached, intelligent ignition management system for instantaneous hot re-ignition of lamp after power outage. State-of-the-art microprocessor technology allows for flicker-free and lamp-preserving rapid lamp start of even hot lamps. Automatic safety cut-off and end-of-life detection prevent abnormal lamp operation and protect the components of the luminaire. The floodlight is connected to the ignitor via a 3-pole terminal of up to 4 mm². With cable gland M20 for cables up to 8 - 13 mm. Windage area FW = 0.16 m2. Control gear box 0860GK···, either for one or two floodlights, made of sheet steel, lightgrey, similar to RAL 7035, powder-coated, weather-resistant. With lockable door. Complete with all necessary control gear, prewired ready for connection. With two or three cable glands M20 for cables up to 6-12 mm. Mains-side connection terminal 5 x 6 mm², luminaire-side terminals 2 x 3 x 6 mm². Parallel-compensated. Safety class I, degree of protection IP65. Supply unit 0860VE··· for one floodlight including Neozed fuse 16 A and 8-pole screw-type terminal 6 mm². With two cable glands M20 for cables up to 7-14 mm. Fixed via two boreholes 12 mm. Parallel-compensated. Safety class I, degree of protection IP65. Lamp data ····························· 360 Reference TOC with ignitor Maxilux, narrow-angle light distribution (T) 7-4201-1207 19 847··· 7-4201-1237 19 848··· Maxilux, narrow/wide-angle light distribution (TB) 7-4202-1207 19 849··· 7-4202-1237 19 850··· 7-4202-1238 19 851··· Maxilux, wide-angle light distribution (B) 7-4203-1207 15 827··· 7-4203-1237 19 842··· 7-4203-1238 19 843··· Maxilux, extremely wide-angle light distribution (SB) 7-4204-1207 19 844··· 7-4204-1237 19 845··· 7-4204-1238 19 846··· Accessories TOC Instantaneous hot reignition (WZ) Lamps Socket ≈ kg W ···50 ···50 - 1 x HIT-DE 1000 1 x HIT-DE 2000 Cable Cable 12.0 12.0 ···50 ···50 - ···50 1 x HIT-DE 1000 1 x HIT-DE 2000 1 x HIT-DE 2000 Cable Cable Cable 12.0 12.0 12.5 ···50 ···50 - ···50 1 x HIT-DE 1000 1 x HIT-DE 2000 1 x HIT-DE 2000 Cable Cable Cable 12.0 12.0 12.5 ···50 ···50 - ···50 1 x HIT-DE 1000 1 x HIT-DE 2000 1 x HIT-DE 2000 Cable Cable Cable 12.0 12.0 12.5 Description ≈ kg 1 x HI/HS 1000 1 x HI... 2000/10,3A 2 x HI/HS 1000 1 x HI... 2000/10,3A 18.1 25.4 36.7 51.3 1 x HIT-DE 1000 13.0 0.2 0.3 15.2 1 x HIT-DE 1000 1 x HIT-DE 2000 1 x HIT-DE 2000 16.0 0.6 0.5 22.7 0860VE/1000HI/HS··· 7-420··· 524 94 420 380 0860GK/2/··· 12 210 12 ¶ 440 wz 300 260 600 0860VE/2000HI/10,3A··· 360 94 400 634 560 210 115 380 340 0860GK/1/··· 494 8,6 8,6 12 12 65 604 295 115 M20 40 M20 120 65 M20 55 55 M20 105 18 x 80 60° 133 60 ¶12 ¶12 80 80 372 TRILUX Spotlights and Floodlights Control gear boxes 0860GK/1/1000HI/HS K 52 483 02 Control gear box for 1xHI/HS 1000 0860GK/1/2000HI/10,3A K 52 485 02 Control gear box for 1xHI 2000/10.3 A 0860GK/2/1000HI/HS KK 52 491 09 Control gear box for 2xHI/HS 1000 0860GK/2/2000HI/10,3A KK 52 493 09 Control gear box for 2xHI 2000/10.3 A Individual components for pole installation for Maxilux···/1000 HIT-DE B 1000 HI/HS 49 421 00 Encapsulated electronic control gear 230 V/50 Hz 6-3801-40 24 943 00 Capacitor 40 µF/230V 6-3801-50 24 948 00 Capacitor 50 µF/230V 0860VE/1000HI/HS K 58 316 00 Supply unit, compensated Individual components for pole installation for Maxilux···/2000 HIT-DE B 2000 HI 10,3A 49 423 00 Encapsulated electronic control gear 380 V/400 V/50 Hz/10.3 A 6-3802-60 24 953 00 Capacitor 60 µF/400V 6-3802-37 24 935 00 Capacitor 37 µF/400V 0860VE/2000HI/10,3A/380V/400V/420V K 58 317 00 Supply unit, compensated for lamps W TRILUX säljs i Sverige genom: PROLJUS AB Kyrkogatan 18 570 03 VRIGSTAD www.proljus.se [email protected] Björn Celén [email protected] 070-601 05 63 Johan Celén [email protected] 070-382 29 63