Mcc-1 Microclimate Controller

   EMBED


Share

Transcript

SPECIFACTIONS G REEN A IR P RODUCTS PROFESSIONAL GREENHOUSE EQUIPMENT MCC-1 Product ................................................. Micro Climate Controller ( MCC-1 ) Maximum Amperage Capacity .......................................................... 12 Amps Normal Output ................................................................................... 115 VAC Warm Up Period ................................................................ less than 5 minutes Operating Temperature Range ...................................................... 0 to + 50° C Operating Humidity Range ...................................................... 5% to 95% RH Thermostat Range ........................................................................ 10° to 110° F Humidity Range ...................................................................... 10% to 90% RH Power Requirement ........................................................................... 110 VAC Dimensions (HxWxD) ...................................................................... 9"x12"x3" Weight ................................................................................................. 7 Pounds Repair Service .............................................................. Return to Manufacture Operating Life Expectancy ..................................................... 7 year minimum Operating Power Requirements ............................ 120 VAC ± 20% 50/60 Hz Relay ................................................................................... Electro Mechanical Mechanical Operations ..................................................................... 1,000,000 Electrical Operations ........................................................................... 100,000 Switching Capacity ...................................................................... 12 Amp Max MICROCLIMATE CONTROLLER MCC-1 CALL YOUR LOCAL DEALER G REEN A IR P RODUCTS P.O. BOX 1318 GRESHAM, OR 97030 503-663-2000 INSTRUCTION MANUAL MICROCLIMATE CONTROLLER MCC-1 The MicroClimate Controller MCC-1 is designed to perform all the major atmospheric and timed functions required in an automated growth environment including temperature, humidity, carbon dioxide enrichment, lighting and irrigation control. The controller incorporates an external coil cooling thermostat , a dehumidifying humidistat, a 24-hour clock timer, a photosensor and a repeat cycle timer. Heating and humidifying control is provided by triggers for remote high-amperage relays which enable synchronized equipment management. Automatic override and defeat systems coordinate controls to consider all possible variables. The MCC-1 is enclosed in a black anodized, brush finish aluminum housing. An attractive screen-printed front panel with function indicator lights makes system monitoring and adjustment quick and easy. All connections are standard 3-prong grounded plugs and receptacles. No hard wiring is required for basic operations. Low and high voltage relays are available to operate auxiliary equipment. Every aspect of the growing environment may be addressed by the Micro Climate Controller (MCC-1). Operates on 115VAC with 12 Amp switching capacity. Approved for indoor only. Intake and/or Exhaust Fan Lighting G REEN A IR P RODUCTS Exhaust Outlet HR-1 Relay Exhaust On Temperature High Humidity High Photo Sensor Timed Outlet CO2 Cycle CO2 Outlet Timer Timer Cycle Outlet 24 Hour Timer OFF Heater Relay FREQUENCY DURATION Humidifing Relay Of "ON" Time Off Timed Outlet CO2 Outlet Of "ON" Time 7m 8 30 15m 7 23 Heating HF-1 Relay 1 6 2 5 HAR-1 The HAR-1 is a power relay that uses high amperage capacity contacts to transfer power to large fans or lighting systems requiring high voltage or amperage service. Use to operate 115 or 240 Volt high draw equipment. 30 Amp switching capacity with 115 Volt trigger. HR-1 The HR-1 is a high amperage relay with a built in external coil heating thermostat. Use to supply 115 or 240 Volt power to heating equipment when tempeature falls below set point. 30 Amp switching capacity for heavy load requirements. A jack receptical and internal low voltage dry contacts are used to function gas type heaters. See MCC-1 installation description. CO2 Equipment or Irrigation HF-1 5s 17 Cycle Timer 3.5m Outlet 15 21 3 Thermostat Dry Contact Switches On Timed Outlet AT M O S P H E R I C S Y S T E M S & C O N T R O L S MCC-1 CDDS-1 Trigger FUNCTION RELAYS 15 5 10 Humidistat Sequence Timer Climate Controller MANUFACTURED BY GREEN AIR PRODUCTS , USA 110VAC 15A MAX Temperature 110 V Outlet Pumps or Solenoid Valves Thie HF-1 is a high amperage relay with a built in humidifying humidistat. Use to supply 115 or 240 Volt power to humidifying equipment when humidity falls below set point. 30 Amp switching capacity for heavy load requirements. G REEN A IR P RODUCTS Exhaust Outlet MCC-1 2 CDMC-2 G REEN A IR P RODUCTS 60 90 50 100 110 30 HF-1 Relay G REEN A IR P RODUCTS AT M O S P H E R I C S Y S T E M S & C O N T R O L S High Amperage Relay 70 8 10 Exhaust/Intake Fans G REEN A IR P RODUCTS AT M O S P H E R I C S Y S T E M S & C O N T R O L S Carbon Dioxide Digital Sequencer CDDS-1 110 V Outlet GREEN AIR PRODUCTS INC. GREEN CO2 "ON". RED CO2 "OFF". A B ppm CDDS-1 50 150 200 300 OFF OFF ON OFF ON ON OFF HYSTERESIS PROGRAMMING OFF ON A ON ON B N/A N/A 50 ppm - 100 ppm - 200 ppm - 400 ppm - 800 ppm - 1600 ppm [] [] [] [] [] [] [] [] [] [] DIGITAL EVENT SEQUENCER ON 3 4 5 6 7 8 9 HOURS 7m MINUTES 30 15m 7 110 30 23 1 5s 15 21 6 10 HAR-1 Digital Setpoint Controller CO2 Outlet 90 20 20 24 Hour Timer 80 100 40 10 80 12 11 70 3 60 50 40 4 High Amperage Relay 5 476 2 5 15 17 Humidistat MANUFACTURED BY GREEN AIR PRODUCTS , USA 110VAC 15A MAX 5 3.5m Cycle Timer 10 3 Thermostat Timed Outlet 6 HR-1 Relay 10 7 Infrared CO2 Sensor CDM-1 12 11 8 240 V Outlet 1 9 Exhaust On Temperature High Humidity High Photo Sensor Timed Outlet CO2 Cycle CO2 Outlet Timer Timer Cycle Outlet OFF Heater Relay Humidifing Relay CDDS-1 Trigger 1 Function Relay Diagram CO2 Equipment Timed Outlet AT M O S P H E R I C S Y S T E M S & C O N T R O L S 2 COMPLETE SYSTEM CONTROL Ferquency Duration Cycle Timer Photo "Off" Light Photo "Off" Light CO2 Equipment CO2 Equipment COCOOffOff Outlet Outlet 2 2 M AMNAUNFA C TCU ROODDUUCCTTSS, , UU S A1111 0 VA 1 0M AAM U FA TR UE RD E DBBYYGGRREEEEN NA A II R R PPR SA 0 VA C 1C0 A XA X Lighting 240 V Outlet HEATER 240 V Outlet G REEN A IR P RODUCTS Exhaust Outlet On Timed Outlet AT M O S P H E R I C S Y S T E M S & C O N T R O L S MCC-1 G REEN A IR P RODUCTS AT M O S P H E R I C S Y S T E M S & C O N T R O L S HR-1 Relay Heating Relay HR-1 80 Of "ON" Time AT M O S P H E R I C S Y S T E M S & C O N T R O L S High Amperage Relay HAR-1 CO2 Outlet 7m 8 60 30 50 23 HF-1 Relay 30 Thermostat 1 6 2 5 15 21 17 3 Thermostat HOW TO OPERATE 15m 7 40 ON 20 Off Timed Outlet Of "ON" Time 70 OFF G REEN A IR P RODUCTS Exhaust On Temperature High Humidity High Photo Sensor Timed Outlet CO2 Cycle CO2 Outlet Timer Timer Cycle Outlet 24 Hour Timer OFF Heater Relay FREQUENCY DURATION Humidifing Relay CDDS-1 Trigger High Amperage Relay 15 5 3.5m 5s Cycle Timer Outlet 10 Humidistat Climate Controller Sequence Timer MANUFACTURED BY GREEN AIR PRODUCTS , USA 110VAC 15A MAX Heating Relay 240 V Outlet 110 V Outlet G REEN A IR P RODUCTS AT M O S P H E R I C S Y S T E M S & C O N T R O L S Atmospheric Controller Humidifying Relay HF-1 80 70 60 OFF 50 40 ON 20 30 Humidistat HUMIDIFIER Pumps, Solenoid Valves or Irrigation Controls Humidifying Relay Use Green Air Products function relays in combination with the MCC-1 to operate high voltage or high amperage equipment. The MCC-1 outlets trigger the relay contactor to close which switches power to the auxiliary equipment. This design protects the controller from power overload and provides precise and dependable system management. See detailed descriptions of function relays. The MCC-1 was designed to be used independently or in conjunction with Green Air Products function relays. The MCC-1 will serve independently for systems and equipment requiring 115 VAC of 12Amps or less. Plug power cord into surge protected outlet and locate controller where good air circulation represents plant zone conditions. Plug exhaust fan into exhaust outlet. Set thermostat and humidistat dials to maximum desired values. Fan will operate when conditions exceed those set points. Function indicator lights will display the condition and outlet status. CO2 equipment can be operated from the CDDS-1 trigger when using the CDMC infrared monitor controller. This outlet provides an exhaust synchronized override feature to delay enrichment during ventilation periods. When timed control is desired plug CO 2 equipment into CO2 outlet and set timer mode toggle switch accordingly. Set the sequence timer duration dial for minutes of "On" time and frequency dial for the time between "On" functions. Exhaust demand will override CO2 production and timer will reset to cycle immediately following ventilation. CO2 outlet is defeated by a built-in photo sensor to operate only when light is present. If not being used for CO2 enrichment the sequence timer can be used for a variety of other timing duties. Switch the mode toggle to "Cycle Timer" to bypass the exhaust and photoperiod defeat circuits. Timer "On" times as short as 5 sec. can be achieved to operate irrigation pumps or solenoids for all kinds of hydroponic and automatic watering systems. Plug thermostatically controlled heater into HR-1 relay trigger outlet. Exhaust operations will override heating trigger to defeat heaters. Use the HR-1 relay outlet for humidifiers to provide a comfort zone between humidifying and dehumidifying. The 24 hour clock timer is useful for all daily oriented timing operations. The 96 independent 15 min trippers allow any combination of on/off functions repeated each 24 hours. Lighting, fans, pumps and watering are only a few of the tasks this timer can perform. If your combined amperage draw exceeds 15 amp power handling capacity of the controller optional high amperage function relays can be used to provide service to large systems. Approved for indoor use only. FUNCTION OUTLET DESCRIPTIONS EXHAUST OUTLET This outlet receives power when excess heat or humidity need to be ventilated. Intake and exhaust fans or other venting equipment can be automatically functioned according to the setpoints on the thermostat and humidistat dial face. There is approximately five points differential between “On” and “Off” cycles to maintain a consistent air quality. CDDS TRIGGER When using a CO2 monitor to determine and control CO2 producing equipment this outlet provides 24 hr. power which is defeated during exhaust functions to minimize CO2 loss. Plug CDMC digital sequencer into this trigger to integrate CO2 management with atmospheric control. HR-1 RELAY This feature provides power for heaters or heating relays. A small heater with built in thermostat can be plugged directly into HR-1 outlet. Larger units must use heating relay HR-1 to isolate high amperage requirements. Set heating thermostat to minimum allowable temperature and cooling thermostat to maximum high temperature. The span between these two settings is the comfort zone. The HR-1 relay outlet will not operate during exhaust functions. G REEN A IR P RODUCTS Exhaust Outlet MCC-1 2 3 4 5 6 7 8 9 10 10 12 11 40 CO2 Outlet HOURS 7m MINUTES 90 30 15m 23 1 2 17 15 MANUFACTURED BY GREEN AIR PRODUCTS , USA 110VAC 15A MAX 5 10 3 Humidistat CO2 OUTLET Carbon dioxide enrichment equipment can be precisely timed through this outlet by the on board cycle timer. This timer will repeat your pre-set “ON” and “Off” periods continuously whenever the photo sensor detects the presence of light. The duration of the “On” cycles are from 5 sec. to 30 min. and the frequency of “On” cycles ( or the “Off” time between them ) is from 7 min. to 8 hrs. The photo sensor mode switch must be in the CO2 timer position for photo and exhaust function defeat circuits. Reset feature will replenish CO2 immediately after exhaust cycle. Switch mode toggle to “Off” for manual reset. 5s 15 21 6 10 5 Thermostat TIMED OUTLETS These outlets are operated by the 24 hr. time clock. Use to function almost any electrical equipment according to time of day settings. This precision synchronous clock provides 96 independent 15 min. On - Off trippers. Use the HAR-1 relay for high amperage or voltage equipment. 7 110 30 20 20 1 110 8 24 Hour Timer 80 100 2 40 30 70 3 50 100 4 60 90 5 80 Timed Outlet 6 70 10 7 60 50 12 11 8 HR-1 Relay 1 9 Exhaust On Temperature High Humidity High Photo Sensor Timed Outlet CO2 Cycle CO2 Outlet Timer Timer Cycle Outlet OFF Heater Relay Humidifing Relay CDDS-1 Trigger HF-1 Relay Timed Outlet AT M O S P H E R I C S Y S T E M S & C O N T R O L S HF-1 RELAY This outlet is similar in function to the HR-1 relay outlet except it is for humidity producing apparatus. Humidifying equipment can not function during dehumidifying cycles. Ferquency Duration Cycle Timer 3.5m Cycle Timer CYCLE OUTLET The cycle outlet utilizes the same internal short cycle timer and operates symotaneously with the CO2 outlet. When the photo sensor mode switch is in the cycle timer position the timer is not interupted by the photo and exhaust defeat circuits. Both outlets will provide 24 hr. sequence timing for irrigation systems, pumps, solinoids, transformers, motors, relays and many other equipment devices. IMPORTANT Make certain the combined amperage draw of all equipment operating through the MCC-1 does not exceed 12 amps. Use function relays to conduct high amperage or alternate voltage currents.