Preview only show first 10 pages with watermark. For full document please download

Mdw 502 Philips

   EMBED

  • Rating

  • Date

    July 2018
  • Size

    159.4KB
  • Views

    9,839
  • Categories


Share

Transcript

Descrição Alojamento: em liga de alumínio injetado, pintado eletrostaticamente em tinta epoxi na cor preta. Refletores: em alumínio de alto grau de pureza, polido e anodizado. Vidros de proteção: temperados com espessura de 4 mm, fixados por aro de alumínio fundido, possuindo sistema de vedação Rendimentos - Refletor de facho aberto (H/S/MDW 502), com lâmpadas: 01 x HPLN 250W: 73% 01 x HPLN 400W: 71% 01 x SON 250W: 75% 01 x SON 400W: 76% 01 x HPI-BU 250W: 76% 01 x HPI-BU 400W: 68% - Refletor de facho fechado (H/S/MDW 503), com lâmpadas: 01 x HPLN 250W: 76% 01 x HPLN 400W: 79% 01 x SON 250W: 80% 01 x SON 400W: 82% 01 x HPI-BU 250W: 79% 01 x HPI-BU 400W: 85% 233 135 Aplicações Áreas industriais internas em geral e principalmente em ambientes cuja atmosfera contenha umidade, vapores, pó e gases, tais como casas de máquina, galvanoplastia, docas, etc. e que requeiram grau de proteção IP 65. com junta de silicone, resistente à ação do tempo, impedindo a entrada de partículas em suspensão. Possui grampos de fechamento em aço inoxidável. Porta-lâmpada: tipo E-40, de porcelana reforçada, rosca em liga de latão niquelado, com contato central telescópico de cobre niquelado, mola estabilizadora em aço inoxidável e antivibratória, impedindo o auto desrosqueamento da lâmpada. Fiação: cabo de seção transversal 2 de 1,5 mm , com isolamento em o PVC 105 C, 750V. Grau de Proteção: IP 65. 355 luminoso. Os refletores são disponíveis em dois tipos: facho aberto (para aplicações em alturas de montagem entre 6 e 9 m) e facho fechado (para aplicações em alturas de montagem acima de 9 m). A luminária é fornecida já equipada com vidro de proteção e alojamento para equipamento auxiliar (que conta com gancho de sustentação). Estas luminárias têm grau de proteção IP 65, para os compartimentos da lâmpada e do equipamento auxiliar. 640 Apresentação Luminária para Iluminação Industrial Interna à prova de gases, vapores e poeira. HDW 502: própria para uma lâmpada a vapor de mercúrio HPLN de 250 ou 400W e equipada com um refletor de facho aberto. HDW 503: própria para uma lâmpada a vapor de mercúrio HPLN de 250 ou 400W e equipada com um refletor de facho fechado. SDW 502: própria para uma lâmpada a vapor de sódio ovóide SON de 250 ou 400W e equipada com um refletor de facho aberto. SDW 503: própria para uma lâmpada a vapor de sódio ovóide SON de 250 ou 400W e equipada com um refletor de facho fechado. MDW 502: própria para uma lâmpada a vapor metálico ovóide HPI-BU de 250 ou 400W e equipada com um refletor de facho aberto. MDW 503: própria para uma lâmpada a vapor metálico ovóide HPI-BU de 250 ou 400W e equipada com um refletor de facho fechado. O Sistema Óptico é composto de um refletor em alumínio de alto grau de pureza, repuxado e anodizado, com alto rendimento HDW / SDW / MDW 502 / 503 560 Iluminação Industrial Medidas em mm ZDK 472 = Ø 432 ZDK 473 = Ø 533 Lâmpada HDW 502/3 01 x HPLN 250W 01 x HPLN 400W SDW 502/3 01 x SON 250W 01 x SON 400W MDW 502/3 01 x HPI-BU 250W 01 x HPI-BU 400W Equipamento da lâmpada Estas lâmpadas exigem equipamento auxiliar: reator, capacitor e ignitor. As luminárias são fornecidas com equipamentos auxiliares conforme Tabela de Dados Técnicos/Pedido. Como Especificar - Luminária para Iluminação Industrial Interna, para lâmpada 01 x HPLN 250W ou 400W; - Luminária para Iluminação Industrial Interna, para lâmpada 01 x SON 250W ou 400W; - Luminária para Iluminação Industrial Interna, para lâmpada 01 x HPI-BU 250W ou 400W; - Alojamento em liga de alumínio injetado, pintado eletrostaticamente em tinta epoxi na cor preta, ajustável e com gancho para sustentação; - Refletores em alumínio de alto grau de pureza, polido e anodizado; - Porta-lâmpada tipo E-40, de porcelana reforçada, rosca em liga de latão niquelado, mola estabilizadora em aço inoxidável e antivibratória; - Fiação em cabo de seção 2 transversal de 1,5 mm , com o isolamento em PVC 105 C, 750V; - Grau de Proteção: IP 65; - Rendimento mínimo: Refletor de facho aberto (H/S/MDW 502), com lâmpadas: 01 x SON 250W: 75% 01 x SON 400W: 76% 01 x HPLN 250W: 73% 01 x HPLN 400W: 71% Refletor de facho fechado (H/S/MDW 503), com lâmpadas: 01 x SON 250W: 80% 01 x SON 400W: 82% 01 x HPLN 250W: 76% 01 x HPLN 400W: 79%. Instalação A luminária pode ser suspensa por meio de um gancho na parte superior do alojamento, conectado a um contra-gancho ou cabo de aço. O refletor é acoplado e fixado ao alojamento por meio de 3 parafusos, além disso é selado com silicone ao alojamento e o conjunto do vidro de proteção com aro é fixado ao refletor através de fechos de aço inoxidável em quatro pontos equidistantes, sendo três deles para fechamento e um para articulação do vidro. Por razões de segurança é necessário aterrar a luminária. Manutenção Pode-se retirar o refletor sem o uso de ferramentas especiais. Para acesso ao equipamento, basta desrosquear os 4 parafusos, sem a necessidade de retirá-los completamente, liberando assim a tampa. A limpeza é feita com um pano de tecido macio e limpo, umedecido numa solução de álcool em água (50%). Embalagem Em um único volume, em caixa de papelão reforçado, facilitando o transporte e o armazenamento, sendo um peça por caixa. Empilhagem máxima: 03 caixas. Dimensões (C x L x H) H/S/MDW 502: 450 x 450 x 580 mm; H/S/MDW 503: 550 x 550 x 530 mm. Tabela de Fator de Utilização - HDW 502 - 1 x HPLN 400 W Fator de 50 Área 30 K 80 50 10 30 10 50 30 70 50 10 30 30 30 10 50 10 10 30 10 30 10 10 0 0 0 0.60 0.80 1.00 1.25 1.50 .47 .54 .60 .66 .69 .45 .51 .56 .60 .63 .41 .47 .52 .57 .60 .46 .54 .59 .64 .68 .44 .51 .55 .60 .62 .42 .49 .54 .60 .64 .40 .46 .51 .56 .59 .38 .44 .49 .54 .57 .40 .46 .51 .55 .58 .38 .44 .49 .53 .56 .37 .43 .48 .52 .55 2.00 2.50 3.00 4.00 5.00 .75 .79 .81 .84 .86 .67 .69 .71 .73 .74 .65 .67 .69 .71 .72 .73 .77 .79 .82 .83 .66 .69 .70 .72 .73 .70 .73 .76 .79 .81 .63 .66 .68 .70 .71 .62 .65 .67 .69 .70 .63 .65 .67 .69 .69 .61 .64 .66 .68 .69 .60 .62 .64 .66 .67 Tabela de Fator de Utilização - HDW 503 - 1 x HPLN 400 W Fator de 50 Área 30 K 80 50 10 30 10 50 30 70 50 10 30 30 30 10 50 10 10 30 10 30 10 10 0 0 0 0.60 0.80 1.00 1.25 1.50 .53 .61 .67 .72 .77 .50 .57 .62 .66 .69 .46 .53 .58 .63 .66 .52 .60 .66 .71 .75 .50 .56 .61 .66 .69 .47 .54 .60 .66 .70 .46 .52 .57 .62 .65 .43 .49 .54 .59 .63 .45 .51 .57 .61 .64 .43 .49 .54 .59 .62 .42 .48 .53 .57 .61 2.00 2.50 3.00 4.00 5.00 .83 .87 .90 .93 .95 .74 .77 .78 .80 .81 .71 .74 .77 .79 .80 .81 .85 .87 .90 .92 .73 .76 .78 .80 .81 .77 .81 .84 .88 .90 .70 .73 .75 .77 .78 .68 .71 .74 .76 .77 .69 .72 .74 .76 .77 .67 .71 .73 .75 .76 .66 .69 .71 .73 .74 Tabela de Fator de Utilização - SDW 502 - 1 x SON 250 W Fator de 50 Área 30 K 80 50 10 30 10 50 30 70 50 10 30 30 30 10 50 10 10 30 10 30 10 10 0 0 0 0.60 0.80 1.00 1.25 1.50 .55 .61 .67 .72 .76 .52 .58 .62 .66 .69 .48 .54 .59 .63 .66 .54 .61 .66 .71 .74 .52 .57 .62 .66 .68 .50 .56 .61 .66 .70 .48 .53 .58 .62 .65 .46 .51 .56 .60 .63 .48 .53 .58 .62 .64 .45 .51 .56 .60 .63 .44 .50 .55 .59 .61 2.00 2.50 3.00 4.00 5.00 .81 .85 .87 .90 .92 .73 .75 .77 .78 .79 .71 .73 .75 .77 .78 .80 .83 .85 .88 .89 .72 .74 .76 .77 .78 .76 .80 .82 .85 .87 .69 .72 .73 .75 .76 .68 .71 .72 .74 .75 .68 .71 .72 .74 .75 .67 .70 .72 .74 .75 .66 .68 .70 .72 .73 Tabela de Fator de Utilização - SDW 502 - 1 x SON 400 W Fator de 50 Área 30 K 80 50 10 30 10 50 30 70 50 10 30 30 30 10 50 10 10 30 10 30 10 10 0 0 0 0.60 0.80 1.00 1.25 1.50 .49 .57 .63 .69 .73 .47 .53 .59 .63 .66 .42 .49 .55 .60 .63 .48 .56 .62 .68 .72 .46 .53 .58 .63 .66 .43 .51 .57 .63 .67 .42 .48 .54 .59 .62 .39 .46 .51 .56 .60 .41 .48 .53 .58 .61 .39 .45 .51 .56 .59 .38 .44 .50 .55 .58 2.00 2.50 3.00 4.00 5.00 .79 .83 .86 .89 .91 .71 .74 .75 .77 .78 .68 .71 .73 .76 .77 .78 .81 .84 .86 .88 .70 .73 .75 .76 .77 .74 .78 .81 .84 .86 .67 .70 .72 .74 .75 .65 .68 .70 .73 .74 .66 .69 .71 .73 .74 .65 .68 .70 .72 .73 .63 .66 .68 .71 .73 Tabela de Fator de Utilização - SDW 503 - 1 x SON 400 W Fator de 50 Área 30 K 80 50 10 30 10 50 30 70 50 10 30 30 30 10 50 10 10 30 10 30 10 10 0 0 0 0.60 0.80 1.00 1.25 1.50 .54 .62 .69 .75 .80 .52 .58 .64 .69 .72 .47 .54 .60 .65 .68 .54 .61 .68 .74 .78 .51 .58 .63 .68 .71 .48 .56 .62 .68 .73 .46 .53 .59 .64 .67 .43 .50 .56 .61 .65 .46 .53 .58 .63 .66 .43 .50 .56 .61 .64 .42 .49 .54 .59 .63 2.00 2.50 3.00 4.00 5.00 .86 .91 .94 .97 .99 .77 .80 .82 .84 .85 .74 .78 .80 .82 .84 .84 .88 .91 .94 .96 .76 .79 .81 .83 .84 .80 .84 .88 .91 .94 .73 .76 .78 .80 .82 .71 .74 .77 .79 .81 .72 .75 .77 .79 .80 .70 .73 .76 .78 .80 .68 .72 .74 .76 .78 180º Curva Polar 150º 130º Diagrama de Luminância e Curvas de Limitação de Ofuscamento Curva de Distribuição Zonal 120º 100 % 600 400 80 % 90º 0º 30º 60º 90º 85º 40 % 75º 20 % 65º 0 180º 30º 55º 45º 60º Curva Polar 150º 130º 0 - 180º 750 500 80 % 90º 0º 30º 60º 90º 85º 40 % 75º 20 % 65º 120º 150º 180º 30º Curva Polar 150º 130º 600 400 90º 0º 30º 30º Qualidade de classe CIE 6 8 10 4 2 2 cd/m Valida para iluminância de serviço E (lx) 2000 1000 500 <300 2000 1000 500 <300 2000 1000 500 <300 A B C 4 2 60º 90º 85º 40 % 75º 20 % 65º 120º 150º 180º Qualidade de classe CIE 6 8 10 3 2 4 6 8 10 4 2 2 cd/m Valida para iluminância de serviço E (lx) 2000 1000 500 <300 2000 1000 500 <300 2000 1000 500 <300 A B C 90 - 270º 60 % 55º 130º 10 2 4 2 6 8 10 3 2 4 6 8 10 4 2 2 cd/m Diagrama de Luminância e Curvas de Limitação de Ofuscamento Curva de Distribuição Zonal 100 % 0 - 180º 600 80 % 400 2 0 - 180º 45º 120º 90º 0º 30º 60º 90º 85º 40 % 75º 20 % 65º 120º 150º 180º 30º Qualidade de classe CIE Valida para iluminância de serviço E (lx) 2000 1000 500 <300 2000 1000 500 <300 2000 1000 500 <300 A B C 90 - 270º 60 % 55º 45º 60º 10 2 4 2 6 8 10 3 2 4 6 8 10 4 2 2 cd/m 50º Curva Polar 150º 130º Diagrama de Luminância e Curvas de Limitação de Ofuscamento Curva de Distribuição Zonal 120º 100 % 0 - 180º 750 80 % 500 4 50º Curva Polar 150º 90º 0º 60º 30º 2 Diagrama de Luminância e Curvas de Limitação de Ofuscamento 60º 0 10 Curva de Distribuição Zonal 80 % 180º 3 50º 100 % 0 6 8 10 55º 45º 120º 180º 4 2 90 - 270º 60 % 60º 0 2 Diagrama de Luminância e Curvas de Limitação de Ofuscamento Curva de Distribuição Zonal 100 % 180º 10 50º 120º 0 Valida para iluminância de serviço E (lx) 2000 1000 500 <300 2000 1000 500 <300 2000 1000 500 <300 A B C 90 - 270º 60 % 120º 150º 180º Qualidade de classe CIE 0 - 180º 50º 30º 60º 90º 85º 40 % 75º 20 % 65º Valida para iluminância de serviço E (lx) 2000 1000 500 <300 2000 1000 500 <300 2000 1000 500 <300 A B C 90 - 270º 60 % 120º 150º 180º Qualidade de classe CIE 55º 45º 10 2 2 4 6 8 10 3 2 4 6 8 10 4 2 2 cd/m Reatores para lâmpadas de descarga Código Comercial Lâmpadas Ignitor Rede (V) Reatores para Lâmpadas a Vapor de Mercúrio VMI250B26 HPL-N 250W VMI400B26 HPL-N 400W - Corrente da Rede (A) VSI400B26 SON 400W HPI-BU 400W Potência (2) Capacitor Circuito de Ligação Corrente Corrigida (µF) (1) (V) (A) 0,60 22,0 16,0 250 1,30 1 220 3,25 0,63 26,0 22,0 250 2,05 1 3,00 0,40 28,0 30,0 250 1,35 2 4,60 0,42 38,0 45,0 250 2,10 2 2,30 0,54 23,0 16,0 250 1,35 3 3,40 0,56 29,0 25,0 250 2,10 3 220 IGN51 Correção Individual do Fator de 2,15 Reatores para Lâmpadas a Vapor Metálico de Alta Pressão IGN51 VMI250B26 HPI-BU 250W 220 VMI400B26 Perdas (W) (3) 220 Reatores para Lâmpadas a Vapor de Sódio de Alta Pressão IGN50 VSI250B26 SON 250W 220 IGN50 Fator de Potência 220 1 - Valores da capacitância para correção do F.P. com capacitores ligados em paralelo à carga; 2 - A correção indicada é para um F.P. médio de 0.92 e a tolerância na capacitância é de 10 %; 3 - Valores médios. Tabela de Dados Técnicos / Pedido Código para pedido Para lâmpada HDW502-1250-64-L 01 x HPLN 250W HDW502-1400-64-L 01 x HPLN 400W HDW503-1250-64-L 01 x HPLN 250W HDW503-1400-64-L 01 x HPLN 400W SDW502-1250-24-L 01 x SON 250W SDW502-1400-24-L 01 x SON 400W SDW503-1250-24-L 01 x SON 250W SDW503-1400-24-L 01 x SON 400W MDW502-1250-44-L 01 x HPI-BU 250W MDW502-1400-44-L 01 x HPI-BU 400W MDW503-1250-44-L 01 x HPI-BU 250W MDW503-1400-44-L 01 x HPI-BU 400W As luminárias acima são fornecidas completas. Circuito de Ligação 1 Reator Peso bruto (Kg) Facho Aberto Facho Aberto Facho Fechado Facho Fechado Facho Aberto Facho Aberto Facho Fechado Facho Fechado Facho Aberto Facho Aberto Facho Fechado Facho Fechado 220 220 220 220 220 220 220 220 220 220 220 220 8,50 9,10 8,65 9,25 8,70 9,30 8,85 9,45 8,60 9,20 8,75 9,35 9,60 10,20 9,75 10,35 9,80 10,40 9,95 10,60 9,70 10,30 9,85 10,50 Am Circuito de Ligação 3 Br Ignitor Vm FF FN Pt Vm Vm FF Capacitor Lâmpada Br Reator Vm Vm Capacitor Peso líquido (Kg) Br Br FN Tensão (V) Circuito de Ligação 2 Reator FF Refletor Pt Lâmpada Capacitor Ignitor Lâmpada FN Tendo em vista a constante atualização tecnológica dos produtos PHILIPS, eventuais modificações poderão ser efetuadas sem aviso prévio. As fotos são meramente ilustrativas. Em caso de dúvidas, consulte o SPOT (Serviço Philips de Orientação Técnica). SERVIÇO PHILIPS DE ORIENTAÇÃO TÉCNICA Fone: 0800-991925 • (11) 5188-0635 • Fax: (11) 5188-0735 LightFax: (11) 5188-0730 • E-mail: [email protected] www.luz.philips.com Philips Luminárias