Preview only show first 10 pages with watermark. For full document please download

Mechanische Installation Ds

   EMBED


Share

Transcript

          DS‐25    Absolute Rotary Electric Encoders™    Mechanical Installation Guide                                              Document No. :DS‐25 mechanical installation guide   Version: 1.01, Feb 2009           Netzer Precision Motion Sensors Ltd.   Misgav Industrial Park, P.O. Box 1359  D.N. Misgav, 20174  Israel  Tel: +972 4 999 0420  Fax: +972 4 999 0432  www.netzerprecision.com   global‐[email protected]     The DS‐25 Electric Encoder™ is semi‐modular, i.e. its rotor and stator are separate, but the rotor is captive  inside the stator. Both rotor and stator are supported by the host machine at their one end and loaded – or  clamped, at their other end.   The encoder can be mounted either on a middle (TBD) of a machine shaft, or at the end of a shaft. A step  can be machined to provide an axial support area for the rotor– as in Figure 1, or the shaft can be smooth  and support the rotor with the aid of a C‐ring as shown in Figure 7b. The axial clamping force on the rotor  can be provided by a factory supplied special wave springs or through the loading of other machine  elements, such as ball bearings.  The (encoder) stator is supported axially at its circumference and is secured to the host machine by means  of three factory supplied (encoder) stator clamps. The stator is supported radially by a recess in the host  machine.   In order to meet the recommended axial tolerance, despite potential manufacturing errors in the host  machine, special compensation shims are available to be placed underneath the stator, or rotor. In  addition, a special gauge can be obtained to assist the selection of the proper shims.                                                  Installation procedure  Figure – 1 Overview  Figure 2 shows the encoder clamps (factory supplied with the encoder) and their engagement slots in the  encoder.   Figure 3 shows the recess in the host machine which supports the encoder both axially and radially, it also  shows the contact areas of the rotor and encoder stator.  The recommended axial distance between surfaces A and B (Figure 3) is 1.5 ± 0.05mm; this is in order to  center the rotor between the stator’s transmitter and receiver plates. Axial misalignment will influence the  raw sine/cosine output signals of the Fine channel – see AN‐2; however, the accuracy and resolution will be  nearly the same ‐ as long as the rotor is within ±0.2mm from the center and does not touch the stator  plates.   www.netzerprecision.com DS‐25, mechanical installation guide  2   Mechanical installation of the encoder involves the following steps:  Step 1:  Validate the axial distance between the machine support areas A and B. Since the actual distance  between surfaces A and B includes the host machine tolerance buildup it is easier to meet the requirement  using compensation shims as follows:  1. Measure the axial distance h between surfaces A and B, If  1.45mm  1.55mm: put a rotor compensation shim (MP‐DS‐25‐SPR0.1 or MP‐DS‐25‐SPR0.05) between  the rotor bottom and surface B.    3. If  h  <1.45mm:  put  a  stator  compensation  shim  (MA‐DS‐25‐SPC0.1  or  MA‐DS‐25‐SPC0.05)  between the stator peripheral rim and surface A.   Note  1:  The  rotor  compensation  layer  is  ring  shaped,  the  (encoder)  stator  compensation  layer is available in thicknesses of 0.1mm and 0.05mm.   Note  2:  The  above  measurement  can  be  eased  using  the  special  gauge  (catalog  #  MP‐DS25‐GAU‐01). The gauge is mounted on the machine shaft and is rotated underneath  the indicator plunger between two positions while the indicator mounting is stationary.    Note  3:  The  electrical  integrity  of  the  installed DS‐25  with  analog  SIN/COS  outputs  can  be  validated as detailed in application note AN‐02.    Note 4: Standard DS encoders are insensitive to ESD and parasitic capacitive coupling from  adjacent  AC  voltages,  however,  it  is  recommended  to  allow  a  discharge  path  of  no  more  than several tens of kΩ between the machine shaft and the electronics’ ground, not leaving  it electrically floating.  Step 2: The encoder clamps are secured by M2 screws on a φ28mm bolt circle.   1. Screw the encoder clamps. Do not forget to include compensation shims, if needed.    2. Unscrew  each  encoder  clamp  slightly  and  make  its  flat  side  face  the  rotation  axis  to  allow  the  insertion of the encoder (stator) into the recess.  3. Turn the encoder in the recess as necessary, to align its slots with the encoder clamps.  4. Tighten the encoder clamps with a torque of 0.1 Nm to fix the stator – as in Figure 1.                              Figure – 2a, deep placing  www.netzerprecision.com Figure – 2b, shallow placing Figure – 3, contact surfaces DS‐25, mechanical installation guide  3 Step 3: Clamp the rotor against a step, or a C‐ring on the machine shaft (surface B in Figure 3) e.g. using  any of the means shown in Figure 6. The clamping force should be 0.3 Nm.                                 Figure 4, Amplitude vs. rotor axial position                             (a)  Deep placing  (a1) Shallow placing  Figure 6, Rotor clamping options – end of shaft   (a) Steeped shaft  (b) Smooth shaft – using “C” ring  Figure 7, Rotor support options  www.netzerprecision.com DS‐25, mechanical installation guide  4     Mechanical dimensions        www.netzerprecision.com   DS‐25 with loose wires DS‐25, mechanical installation guide  5 DS‐25, Accessories (Dimensions in are in mm)  DS‐25 , Shallow placing  Encoder clamp  With  bolt UNF‐0‐80    Cat No.   MA‐DS‐25‐SCLMP‐01      DS‐25 , Deep placing  Encoder clamp  With  bolt M2    Cat No.   EAMP7049    www.netzerprecision.com                                             Dimensions in mm                                                        DS‐25, mechanical installation guide  6             DS‐25 Rotor shims     0.1 mm  Cat No. MP‐DS25‐SPR0.10              0.05 mm  Cat No. MP‐DS25‐SPR0.05                    DS‐25 Stator shims     0.1 mm  Cat No. MP‐DS25‐SPC0.10          0.05 mm  Cat No. MP‐DS25‐SPC0.05  www.netzerprecision.com                                                                                             DS‐25, mechanical installation guide  7             DS‐25 Measurement gauge     Cat. No. MP‐DS25‐GAU01                                                                  DS‐25 Retaining ring     Cat. No. MP‐00070                                                  www.netzerprecision.com DS‐25, mechanical installation guide  8 1 2 3 B.C. 4 5 6 30 ±0.05 6 A A 5 4 3 2 B B 1 25 +0.05 0 23 6 3.5 ±0.1 5.4 ±0.1 C 0.50 min C 3 X M2 X 120 1.5 ±0.05 6 M3 8 min 7 0 - 0.05 Assembly Scale 2 : 1 Host system mounting details D NO. PART NAME CATALOG NO. QTY 1 Host shaft - 1 2 Host base - 3 DS-25 Encoder 4 Encoder clamp EAMP7049 3 5 Washer DIN 125 - A 3.2 MP-00064 1 6 Bolt M3 (DIN 7984) MP-00062 1 1 1 1 2 Title: DS-25 Installation: Shaft end, stepped shaft, deep installation Date: Jan 09 SHEET 1 OF 1 3 4 A4 Version: 0.5 SCALE: 1.5 : 1 Dimensions : mm 5 1 2 3 B.C. 4 5 6 28 ±0.05 6 A A 5 4 3 2 B B 1 25 +0.05 0 23 8 min 7 0 6 - 0.05 5 X 120 3.5 ±0.1 1.5 ±0.05 C 1 ±0.08 C 3 X #0-80 6 0.50 min M3 Host system mounting details D Assembly Scale 2 : 1 NO. PART NAME CATALOG NO. QTY 1 Host shaft - 1 2 Host base - 3 DS-25 Encoder 4 DS-25 encoder clamp 5 Washer DIN 125 - A 3.2 MP-00064 1 6 Bolt M3 (DIN 7984) MP-00062 1 1 1 1 MA-DS25-SCLMP-01 2 Title: 3 DS-25 Installation: Shaft end, stepped shaft Date: Jan 09 SHEET 1 OF 1 3 4 A4 Version: 0.5 SCALE: 1.5 : 1 Dimensions : mm 5 1 2 3 B.C. 4 5 6 28 ±0.05 7 A A 6 5 4 3 2 B B 1 25 +0.05 0 23 6 8 min 0 - 0.05 3 X #0-80 5.7 ±0.1 M3 5 X 120 6 C D NO. PART NAME CATALOG NO. QTY 1 Host shaft - 1 2 Host base - 1 3 DS-25 Retaining ring MP-00070 1 4 DS-25 Encoder 5 DS-25 encoder clamp MA-DS25-SCLMP-01 3 6 Washer DIN 125 - A 3.2 MP-00064 1 7 DIN 7984 - M3 x 5 --- 3.5N MP-00062 1 1 1 2 1.2 ±0.05 (using item no. 3) Host system mounting details 3.8 ±0.1 0.38 ±0.05 0.5 min 1 ±0.08 C Assembly Scale 2 : 1 Title: DS-25 Installation: Shaft end, smooth shaft Date: Jan 09 SHEET 1 OF 1 3 4 A4 Version: 0.3 SCALE: 1.5 : 1 Dimensions : mm 5 1 2 3 4 Measurement of rotor support surface 5 6 Measurement of stator support surface A B B D = 4.50 A Gauge Gauge C C 5 4 NO. D PART NAME CATALOG # QTY 1 Host shaft - 1 2 Host base - 1 3 DS-25 installation gauge MP-DS25-GAU-01 1 4 Washer DIN 125 - A 3.2 MP-00064 1 5 Bolt M3 x 5 (DIN 7984) MP-00062 1 1 2 3 2 1 3 Title: DS-25 Installation: Machine measurement gauge Date: Jan 09 Version: 0.2 SHEET 1 OF 1 SCALE: 4 A4 1.5 : 1 Dimensions : mm 5