Transcript
Medallion 6000 Series 1550 nm Externally-Modulated Transmitter DATASHEET | OCTOBER 2013
FIBER OPTICS
The L-Type/D-Type/S-Type/F-Type/N-Type Medallion 6000 Series
Applications High-Performance Supertrunking Links High Power Distribution Networks Redundant Ring Architectures FTTx Networks RFoG Applications SAT-IF Transport DWDM Node Splitting
Features Single or Dual Optical Outputs QAM Loading to 1003 MHz Dual Power Supplies, Redundant & Hot Swappable Front Panel RF Test Point SNMP Control Interface WEB GUI Vacuum Fluorescent Status Display OMI / RF Gain Adjustment AGC Select: CW, Video, Manual (No AGC) Industry Leading Field Adjustable SBS Suppression Field Adjustable Electronic
The Medallion 6000 series is a family of state-of-the-art high-performance 1550 nm externally-modulated CATV fiber optic transmitters optimized for varying network applications. Packaged in convenient 1 RU housing, this line of optical transmitters couples high optical output powers, up to 11.0 dBm, with low optical linewidth resulting in unmatched performance. The optical modulator, combined with proprietary pre-distortion circuitry, provides superior CTB and CSO performance with SBS suppression levels of greater than 21 dBm. Advanced features such as built-in field adjustable SBS control and electronic dispersion compensation allow these transmitters to be quickly optimized in the field for any link or application without the need to procure specifically tuned transmitters. This affords the system designer a level of flexibility previously unknown in the CATV market place. The L-Type series are designed as a high-performance solution for applications where the simultaneous transport of CATV and SAT-IF FM signals is required. The SAT-IF signals can be applied anywhere in the 950 to 2800 MHz band. The D-Type series are designed as a low cost, high-performance solution for applications where the required fiber length is in the range of 20 to 50 kilometers. Advanced, high power, DFB laser technology allows these transmitters to be fielded without the use of EDFAs. The S-Type series transmitters are designed to be the most versatile models within the Medallion 6000 series family. They can easily be configured to meet most HFC network solutions requiring link lengths in the range of 50 to 70 kilometers with one EDFA as well as links utilizing multiple EDFA’s. The F-Type series transmitters are intended for use in FTTx and RFoG architecture designs requiring high-quality transmission over varying transmission lengths and EDFA output powers. These transmitters successfully support very high optical launch powers while controlling the detrimental effects of Stimulated Brillouin Scattering (SBS), group velocity dispersion (GVD), and self phase modulation (SPM). The N-Type series transmitters are intended for use in node-splitting architecture designs requiring cost effective DWDM transmission over medium length fiber distances.
Dispersion Compensation (EDC)
Provided by:| REV Mega Hertz 800-883-8839
[email protected] www.go2mhz.com 2013.10 Information contained herein is deemed reliable and accurate as of the issue date. EMCORE reserves the right to change the design or specification at any time without notice.
Medallion 6000 Series 1550 nm Externally-Modulated Transmitter FIBER OPTICS
DATASHEET | OCTOBER 2013
Optical / Electrical Characteristics L-Type Property Performance (Note 1-8) Specified Link Length
Units 6000-L01 L (km)
Channel Plan Optical Output Power
Po (dBm)
Models 6000-L02 6000-L03
Comments 6000-L04
25
25
25
25
NTSC 80-Ch
PAL 60-Ch
NTSC 110-ch
PAL 89-Ch
8.5/8.5
8.5/8.5
8.5/8.5
8.5/8.5
With 36 QPSK carriers from 950 to 2800 MHz Min. 10 dBm version avail. See Chart
Noise Bandwidth
BW (MHz)
4
5
4
5
SBS Suppression
(dBm)
15.0
15.0
15.0
15.0
Min.
CATV Carrier to Noise Ratio
CNR (dB)
51.0
51.0
49.5
49.5
Min.
CATV Composite Second Order
CSO (dBc)
-65
-65
-65
-65
Max. Port 1
CATV Composite Triple Beat
CTB (dBc)
-65
-65
-65
-65
Max. @ +25°C
CATV Composite Triple Beat
CTB (dBc)
-64
-64
-64
-64
Max. @ 0 C to 50 C
SAT-IF Carrier to Noise Ratio
CNR (dB)
27
27
27
27
Min.
SAT-IF Intermodulation Products
(dBc)
-35
-35
-35
-35
Max. Port 1
SAT-IF Spurious Products
(dBc)
-38
-38
-38
-38
Max.
o
o
D-Type Property Performance (Note 1-7) Specified Link Length
Units 6000-D01 L (km)
Channel Plan
Models 6000-D02 6000-D03
Comments 6000-D04
40
40
40
40
NTSC 80-Ch
PAL 60-Ch
NTSC 110-ch
PAL 89-Ch
Optical Output Power
Po (dBm)
11.0
11.0
11.0
11.0
Noise Bandwidth
BW (MHz)
4
5
4
5
Min.
SBS Suppression
(dBm)
> 12.0
>12.0
>12.0
>12.0
Min.
Carrier to Noise Ratio
CNR (dB)
54.0
54.0
51.0
51.0
Min.
Composite Second Order
CSO (dBc)
-65
-65
-65
-65
Max.
Composite Triple Beat
CTB (dBc)
-65
-65
-65
-65
Max. @ +25°C
Composite Triple Beat
CTB (dBc)
-64
-64
-64
-64
Max. @ 0 C to 50 C
o
o
S-Type Property Performance (Note 1-7) Specified Link Length
Units 6000-SA1 L (km)
Channel Plan
6000-SA2
Models 6000-SA3
6000-SA4
Comments 6000-SA5
65
65
65
65
65
NTSC 80
PAL 60
NTSC 110
PAL 89
42 CENELEC Min. - Higher Powers Available See Chart
Optical Output Power
Po (dBm)
7.0/ 7.0
7.0/ 7.0
7.0/ 7.0
7.0/ 7.0
7.0/ 7.0
Noise Bandwidth
BW (MHz)
4
5
4
5
5
SBS Suppression
(dBm)
16.0
16.0
16.0
16.0
16.0
Min.
Carrier to Noise Ratio
CNR (dB)
53.0/ 53.0
53.0/ 53.0
50.0/ 50.0
50.0/ 50.0
53.0/ 53.0
Min.
Composite Second Order
CSO (dBc)
-65/ -65
-65/ -65
-65/ -65
-65/ -65
-65/ -65
Max.
Composite Triple Beat
CTB (dBc)
-65
-65
-65
-65
-65
Max. @ +25°C
Composite Triple Beat
CTB (dBc)
-64
-64
-64
-64
-64
Max. @ 0 C to 50 C
o
| REV 2013.10
Information contained herein is deemed reliable and accurate as of the issue date. EMCORE reserves the right to change the design or specification at any time without notice.
o
Medallion 6000 Series 1550 nm Externally-Modulated Transmitter FIBER OPTICS
DATASHEET | OCTOBER 2013
F-type Property Performance (Note 1-7) Specified Link Length
Units 6000-F01 L (km)
Channel Plan Optical Output Power
Po (dBm)
6000-F02
Models 6000-F03
Comments 6000-F04
20
20
20
20
NTSC 80-Ch
PAL 60-Ch
NTSC 110-ch
PAL 89-Ch
7.0/ 7.0
7.0/ 7.0
7.0/ 7.0
7.0/ 7.0
Min.
Noise Bandwidth
BW (MHz)
4
5
4
5
SBS Suppression
(dBm)
21.0
21.0
21.0
21.0
Min.
Carrier to Noise Ratio
CNR (dB)
48.0
48.0
45.0
45.0
Min.
Composite Second Order
CSO (dBc)
-58
-58
-58
-58
Max.
Composite Triple Beat
CTB (dBc)
-58
-58
-58
-58
Max.
N-Type Property Performance (Note 1-7) Specified Link Length
Units 6000-N01 L (km)
Channel Plan
Models 6000-N02
40
40
NTSC 80-Ch
PAL 60-Ch
Optical Output Power
Po (dBm)
9.5
9.5
Noise Bandwidth
BW (MHz)
4
5
SBS Suppression
(dBm)
13.0
13.0
Comments
Min. Min.
Carrier to Noise Ratio
CNR (dB)
52.0
52.0
Min.
Composite Second Order
CSO (dBc)
-62
-62
Max.
Composite Triple Beat
CTB (dBc)
-62
-62
Max. @ +25°C
Composite Triple Beat
CTB (dBc)
-61
-61
Max. @ 0 C to 50 C
o
o
Notes: 1. Unless stated otherwise all specifications apply over full temperature range with no digital loading. 2. Unless stated otherwise specifications apply for nominal RF input level as defined below, after a 30 minute stabilization period. 3. Specifications separated by a slash are port1 / port 2. 4. Units are tested per the Test / Link Configuration Table 5. Noise figure for the EDFA = 4.5 ~ 5.5 dB 6. Corning SMF-28 single mode fiber 7. Receiver responsivity is 0.95 mA/mW, Equivalent noise current is 7 pA/(Hz)1/2 8. With 36 QPSK modulated SAT-IF signals between 950 … 2800 MHz. 27 MHz IF bandwidth
| REV 2013.10
Information contained herein is deemed reliable and accurate as of the issue date. EMCORE reserves the right to change the design or specification at any time without notice.
Medallion 6000 Series 1550 nm Externally-Modulated Transmitter FIBER OPTICS
DATASHEET | OCTOBER 2013
General and Mechanical Specifications Property
Requirement
Comments
Wavelength
1550 +/-5 nm
Various Options + ITU-grid available – see Model Number Information
Channel Plan
Various – See Specification Tables
Custom channel plans available
Optical Connector
SC/APC
Other styles available
100 Base-T Ethernet (SNMP) Rear Panel RS-232 interface VFD Screen Front Panel Controls
VFD- (Vacuum Fluorescent Display)
Monitoring Interfaces
Operating Temperature
0°C to 50°C
Storage Temperature
-20°C to 70°C
Power Consumption
65 W max
Agency Listings
EMI: EN50083-2:2006 (US CATV) EN55022:2006 (US IT) EN61000-3-2 (Harmonics) EN61000-3-3 (Flicker) FCC: Part 15, Subpart B, class “A” Unintentional Radiators ICES-003 (Canada) AN/NZS 3548, Class A (Australia) VCCI, Class A (Japan)
Safety: FDA/CDRH Laser Safety Governed by Code of Federal Regulations Title 21, Volume 8, Part 1040 IEC 60950-1 IEC 60728-11 Laser IEC 60825-1 CB Certification
Transportation Vibration
GR-2853-CORE
In Shipping package
Transportation Shock
GR-2853-CORE
In Shipping package
Operating Humidity
20% to 85%
Non-condensing
Supply Range
(VAC)
90 to 265 VAC, 50/60 Hz
Dimensions
19.0”W x 15.0”D x 1.72”H
(width includes 19” front panel ears, depth includes, connectors, fans & front panel) – see drawing
Input Power Range
17 +/-1 dBmV/ch 80 NTSC channels
Manual mode
Input Power Range
15 +/-1 dBmV/ch 110 NTSC channels
Manual mode
18 +/-1 dBmV/ch 60 PAL channels
Manual mode
20 +/-1 dBmV/ch 42 CENELEC channels
Manual mode
16 +/-1 dBmV/ch 89 PAL channels
Manual mode
27 +/-1 dBmV/ch SAT-IF channels
Manual mode
19 +/-2 dBmV/ch 80 NTSC channels
CW mode
17 +/-2 dBmV/ch 110 NTSC channels
CW mode
20 +/-2 dBmV/ch 60 PAL channels
CW mode
18 +/-2 dBmV/ch 89 PAL channels
CW mode
22 +/-2 dBmV/ch 42 CENELEC channels
CW mode
29 +/-2 dBmV/ch SAT-IF channels
AGC mode
| REV 2013.10
Information contained herein is deemed reliable and accurate as of the issue date. EMCORE reserves the right to change the design or specification at any time without notice.
Medallion 6000 Series 1550 nm Externally-Modulated Transmitter FIBER OPTICS
DATASHEET | OCTOBER 2013
General and Mechanical Specifications (continued) Property
Requirement
Front Panel RF Gain / OMI Adjustment Range
Comments
+2 / -4 dB from nominal setting
CATV Performance can vary slightly
CATV Frequency Range
45 MHz – 1003 MHz
CATV Flatness
+/- 0.50 dB
45 MHz – 550 MHz
+/- 0.75 dB
45 MHz – 1003 MHz
CATV Flatness – N-Type
+/- 0.75 dB
45 MHz – 1003 MHz N-Type
CATV Input impedance
75 Ω
CATV Input Return Loss
16 dB min
CATV Front Panel RF Tap
-20 +/- 1 dB down from RF input
45 MHz – 1003 MHz
CATV Front Panel RF Tap Flatness
+/- 1 dB
SAT-IF Frequency Range
950 MHz – 2800 MHz
45 MHz – 1003 MHz
SAT-IF Flatness
+/- 2 dB
SAT-IF Input impedance
75 Ω
SAT-IF Input Return Loss
10 dB min
SAT-IF Front Panel RF Tap
7 +/- 2.5 dBmV/Ch at 1% OMI/ch
SAT-IF Front Panel RF Tap Flatness
+/- 1 dB
950 MHz – 2800 MHz 950 MHz – 2800 MHz
Test/Link Configuration Property
Link1
EDFA
Received Power2
L-Type
15 dBm
25 Km
0.0 dBm at the receiver
D-Type
None
40 Km
0.0 dBm at the receiver
S-Type
16 dBm
65 Km
0.0 dBm at the receiver
F-Type
21 dBm
20 Km
-5.5 dBm at the receiver
N-Type
13 dBm
40 Km
0.0 dBm at the receiver
| REV 2013.10
Information contained herein is deemed reliable and accurate as of the issue date. EMCORE reserves the right to change the design or specification at any time without notice.
Medallion 6000 Series 1550 nm Externally-Modulated Transmitter DATASHEET | OCTOBER 2013
FIBER OPTICS
Outline Drawing (Dimensions in inches)
Laser Safety Information This product meets the applicable requirements of 21 CFR 1010 & 1040 and is classified as a Class 1M laser product. During use as intended, the laser energy is fully contained within the fiber network such that there is no accessible laser radiation. This product has been issued accession number 0820466-001.
| REV 2013.10
Information contained herein is deemed reliable and accurate as of the issue date. EMCORE reserves the right to change the design or specification at any time without notice.
Medallion 6000 Series 1550 nm Externally-Modulated Transmitter FIBER OPTICS
DATASHEET | OCTOBER 2013
Model Number Information (note 3)
6000 – Logo & Customer Specific
□□□ □-□ □□□□ Pout (dBm min) Note 1
Link type
Loading Type
Optics
RF
0– EMCORE Logo
D – 40 km
0 – for D, and F-Types
1 – NTSC (80-ch)
1 – SC/APC, Rear
1 – no Logo
S – 65 km
A – 7.0/7.0 for S-Type
2 – PAL (60-ch)
2 – FC/APC, Rear
B – 8.0/8.0 for S-Type
3 – NTSC (110-ch)
3 – E2000/APC, Rear
3 – RF IN Front, TP Rear
F – FTTx SBS 20 dBm
C – 10.0 for S-Type
4 – PAL (89-ch)
4 – SC/APC, Front
4 – RF IN Rear, TP Rear
L – 25 km
Note 4
D- 10/10 for S & L-Type
5 – Not Used
N – 40 km
E – 8.5/8.5 for L Type
6 – CENELEC (42ch) Note 5
1 – RF IN Rear, TP Front 2 – RF IN Front, TP Front
Wavelength (nm)
Power Supply
00 –1555+/5.0nm
1 – AC primary, no secondary
01 – 1550+/5.0nm
2 – DC primary, no secondary
xx – ITU Channel +/Note 2 0.1nm
3 – AC primary, AC secondary
5 – FC/APC, Front
4 – AC primary, DC secondary 5 – DC primary, DC secondary
6 – E2000/APC, Front
Note 1: Options available for Indicated Types only. Note 2: ITU grid wavelengths can be specified from channel 18 to 40. Note 3: Not all configurations are available, contact factory. Note 4: Available for S and L Links. CSO port 2 degraded by 1dB for Channel Loads 1 and 2, CSO port 2 degraded by 2 dB for Channel Loads 3 and 4. Note 5: Contact Factory for Model type availability
Additional Kits G3708-006-001 - Replaceable AC power supply modules G3708-005-001 - Replaceable DC power supply modules G7914-076-001 - Replaceable Blank power module plate G3906-008-001 - Replaceable fans
Provided by: Mega Hertz 800-883-8839
[email protected] www.go2mhz.com | REV 2013.10
Information contained herein is deemed reliable and accurate as of the issue date. EMCORE reserves the right to change the design or specification at any time without notice.